Literature DB >> 15355393

Predicting osseointegration by means of implant primary stability.

Rabah Nedir1, Mark Bischof, Serge Szmukler-Moncler, Jean-Pierre Bernard, Jacky Samson.   

Abstract

The purpose of the present clinical study was (1) to evaluate the Osstell as a diagnostic tool capable of differentiating between stable and mobile ITI implants, (2) to evaluate a cut-off threshold implant stability quotient (ISQ) value obtained at implant placement (ISQitv) that might be predictive of osseointegration, (3) to compare the predictive ISQitv of immediately loaded (IL) implants and implants loaded after 3 months (DL). Two patient groups were enrolled, 18 patients received 63 IL implants and 18 patients were treated with 43 DL implants. The ISQ was recorded at implant placement, after 1, 2, 4, 6, 8, 10 and 12 weeks. All implants passed the 1-year loading control. Two implants failed, one DL implant with ISQ at placement (ISQi) of 48 and one IL implant with ISQi of 53. The resonance-frequency analysis (RFA) method was not a reliable diagnostic tool to identify mobile implants. However, implant stability could be reliably determined for implants displaying an ISQ> or =47. After 1 year of loading, all DL implants with an ISQi> or =49 and all IL implants with an ISQi> or =54 achieved and maintained osseointegration. By the end of 3 months, implants with ISQi<60 had an increase of stability. Implants with ISQi 60-69 had their stability decrease during 8 weeks before returning to their initial values. Implants with ISQ>69 had their stability decrease during the first 4 weeks before remaining stable. Although preliminary, these data might orient the practitioner to choose among various loading protocols and to selectively monitor implants during the healing phase.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15355393     DOI: 10.1111/j.1600-0501.2004.01059.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  49 in total

1.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

2.  Implant stability evaluation by resonance frequency analysis in the fit lock technique. A clinical study.

Authors:  Giovanni Falisi; Massimo Galli; Pedro Vittorini Velasquez; Juan Carlos Gallegos Rivera; Carlo Di Paolo
Journal:  Ann Stomatol (Roma)       Date:  2013-06-25

3.  Stability of dental implants after irradiation with an 830-nm low-level laser: a double-blind randomized clinical study.

Authors:  Joelle Marie García-Morales; Pedro Tortamano-Neto; Francisco Fernando Todescan; José Carlos Silva de Andrade; Juliana Marotti; Denise Maria Zezell
Journal:  Lasers Med Sci       Date:  2011-07-06       Impact factor: 3.161

Review 4.  Implants in bone: part II. Research on implant osseointegration: material testing, mechanical testing, imaging and histoanalytical methods.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-21

5.  Implant stability in different techniques of surgical sites preparation: an in vitro study.

Authors:  C Rastelli; G Falisi; R Gatto; M Galli; E Saccone; M Severino; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

6.  Effects on the torsional vibration behavior in the investigation of dental implant osseointegration using resonance frequency analysis: a numerical approach.

Authors:  Min Zhai; Bing Li; Dehua Li
Journal:  Med Biol Eng Comput       Date:  2017-02-07       Impact factor: 2.602

7.  Memetic Search Optimization Along with Genetic Scale Recurrent Neural Network for Predictive Rate of Implant Treatment.

Authors:  Abdulaziz Alarifi; Ahmad Ali AlZubi
Journal:  J Med Syst       Date:  2018-09-17       Impact factor: 4.460

8.  Predictive values of resonance frequency analysis as a diagnostic tool in palatal implant loss.

Authors:  Katja Wieczorek; Winfried Harzer; Heinrich Wehrbein; Maximilian Moergel; Martin Kunkel; Britta A Jung
Journal:  Angle Orthod       Date:  2019-03-18       Impact factor: 2.079

9.  Effects of low-intensity pulsed ultrasound on dental implant osseointegration: a preliminary report.

Authors:  Yakup Ustun; Ozgur Erdogan; Mehmet Kurkcu; Tolga Akova; Ibrahim Damlar
Journal:  Eur J Dent       Date:  2008-10

10.  A comparison of the implant stability among various implant systems: clinical study.

Authors:  Jae-Min Kim; Sun-Jong Kim; Inho Han; Sang-Wan Shin; Jae-Jun Ryu
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.