Literature DB >> 15354915

Arterial cannulation: a critical review.

Teresa R Cousins1, John M O'Donnell.   

Abstract

Arterial catheterization for hemodynamic monitoring is used widely in clinical management. Complications of connulation have been recognized since introduction of the technique. This review examines radial, brachial, axillary, and femoral cannulation sites. Waveform distortion, adjacent structure injury, and the incidence of thrombus are described. Computerized subject heading searches were executed using CINAHL and MEDLINE databases. Searches encompassed English-language, randomized, controlled trials, reviews, practice guidelines, and meta-analyses published from January 1997 to February 2002. Additional studies were identified via review of retrieved literature. Radial cannulation is subject to inaccuracy and thrombus formation, although a benefit is dual circulation. The brachial site is subject to inaccuracy, lacks collateral circulation, and is associated with median nerve injury. Axillary cannulation provides data closely approximating aortic pressure and poses minimal thrombotic risk but is associated with brachial plexus compression. Femoral cannulation provides a pulse contour approximating aortic with minimal thrombotic risk. There is little evidence to show increased incidence of catheter-related systemic infection at this site.

Entities:  

Mesh:

Year:  2004        PMID: 15354915

Source DB:  PubMed          Journal:  AANA J        ISSN: 0094-6354


  18 in total

1.  Hand ischaemia after radial artery cannulation.

Authors:  Ozkan Onal; Ebru Salman; Fahri Yetisir; Mehmet Kilic
Journal:  BMJ Case Rep       Date:  2015-08-04

2.  Clustering-initiated factor analysis application for tissue classification in dynamic brain positron emission tomography.

Authors:  Rostyslav Boutchko; Debasis Mitra; Suzanne L Baker; William J Jagust; Grant T Gullberg
Journal:  J Cereb Blood Flow Metab       Date:  2015-04-22       Impact factor: 6.200

3.  Use of 1-ml hollow tube-assisted radial artery catheterization in clinical anesthesiology.

Authors:  Yong-Hua Li; Yong-Qiang Wang; Lin Zeng; Wei Chen; Li-Ye Yang; Qiu-Feng Zhu; Hai-Long Fu
Journal:  Int J Clin Exp Med       Date:  2014-09-15

4.  Accurate end systole detection in dicrotic notch-less arterial pressure waveforms.

Authors:  Joel Balmer; Rachel Smith; Christopher G Pretty; Thomas Desaive; Geoff M Shaw; J Geoffrey Chase
Journal:  J Clin Monit Comput       Date:  2020-02-11       Impact factor: 2.502

5.  Evaluation of the VIA Blood Chemistry Monitor for Glucose in Healthy and Diabetic Volunteers.

Authors:  Arjunan Ganesh; Brian Hipszer; Navdeep Loomba; Barbara Simon; Marc C Torjman; Jeffrey Joseph
Journal:  J Diabetes Sci Technol       Date:  2008-03

6.  Intraarterial catheter diameter and dynamic response of arterial pressure monitoring system: a randomized controlled trial.

Authors:  Hyongmin Oh; Suk Hyung Choe; Yoon Jung Kim; Hyun-Kyu Yoon; Hyung-Chul Lee; Hee-Pyoung Park
Journal:  J Clin Monit Comput       Date:  2021-02-01       Impact factor: 2.502

7.  Use of the PiCCO system in critically ill patients with septic shock and acute respiratory distress syndrome: a study protocol for a randomized controlled trial.

Authors:  Zhongheng Zhang; Xiao Xu; Min Yao; Huilan Chen; Hongying Ni; Haozhe Fan
Journal:  Trials       Date:  2013-02-01       Impact factor: 2.279

8.  Volkman's Contracture, Persistent Limb Ischaemia, and Amputation: A Complication of Brachial Artery Catheterisation for Haemodynamic Monitoring Using PiCCO.

Authors:  Veejay Bagga; Marion Palmer; Ramesh Sadasivan; Govindan Raghuraman
Journal:  Case Rep Crit Care       Date:  2013-09-26

9.  Continuous stroke volume estimation from aortic pressure using zero dimensional cardiovascular model: proof of concept study from porcine experiments.

Authors:  Shun Kamoi; Christopher Pretty; Paul Docherty; Dougie Squire; James Revie; Yeong Shiong Chiew; Thomas Desaive; Geoffrey M Shaw; J Geoffrey Chase
Journal:  PLoS One       Date:  2014-07-17       Impact factor: 3.240

10.  Comparison of the non-invasive Nexfin® monitor with conventional methods for the measurement of arterial blood pressure in moderate risk orthopaedic surgery patients.

Authors:  Felix Balzer; Marit Habicher; Michael Sander; Julian Sterr; Stephanie Scholz; Aarne Feldheiser; Michael Müller; Carsten Perka; Sascha Treskatsch
Journal:  J Int Med Res       Date:  2016-05-02       Impact factor: 1.671

View more