Accurate end systole detection in dicrotic notch-less arterial pressure waveforms.

Joel Balmer1, Rachel Smith2, Christopher G Pretty2, Thomas Desaive3, Geoff M Shaw2, J Geoffrey Chase2.   

Abstract

Identification of end systole is often necessary when studying events specific to systole or diastole, for example, models that estimate cardiac function and systolic time intervals like left ventricular ejection duration. In proximal arterial pressure waveforms, such as from the aorta, the dicrotic notch marks this transition from systole to diastole. However, distal arterial pressure measures are more common in a clinical setting, typically containing no dicrotic notch. This study defines a new end systole detection algorithm, for dicrotic notch-less arterial waveforms. The new algorithm utilises the beta distribution probability density function as a weighting function, which is adaptive based on previous heartbeats end systole locations. Its accuracy is compared with an existing end systole estimation method, on dicrotic notch-less distal pressure waveforms. Because there are no dicrotic notches defining end systole, validating which method performed better is more difficult. Thus, a validation method is developed using dicrotic notch locations from simultaneously measured aortic pressure, forward projected by pulse transit time (PTT) to the more distal pressure signal. Systolic durations, estimated by each of the end systole estimates, are then compared to the validation systolic duration provided by the PTT based end systole point. Data comes from ten pigs, across two protocols testing the algorithms under different hemodynamic states. The resulting mean difference ± limits of agreement between measured and estimated systolic duration, of [Formula: see text] versus [Formula: see text], for the new and existing algorithms respectively, indicate the new algorithms superiority.

Entities:  

Keywords:  Cardiovascular system; Dicrotic notch; End systole; Pressure contour interpretation; Start diastole

Year:  2020        PMID: 32048103     DOI: 10.1007/s10877-020-00473-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  2 in total

1.  Maximal negative dP/dt as an indicator of end of systole.

Authors:  F L Abel
Journal:  Am J Physiol       Date:  1981-04

Review 2.  Arterial cannulation: a critical review.

Authors:  Teresa R Cousins; John M O'Donnell
Journal:  AANA J       Date:  2004-08
  2 in total
  2 in total

Review 1.  An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications.

Authors:  Alessandra Galli; Roel J H Montree; Shuhao Que; Elisabetta Peri; Rik Vullings
Journal:  Sensors (Basel)       Date:  2022-05-26       Impact factor: 3.847

2.  Automated Segmentation of the Systolic and Diastolic Phases in Wrist Pulse Signal Using Long Short-Term Memory Network.

Authors:  Lin Huang; Jianjun Yan; Shiyu Cai; Rui Guo; Haixia Yan; Yiqin Wang
Journal:  Biomed Res Int       Date:  2022-08-21       Impact factor: 3.246

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.