Literature DB >> 15348542

The study of metal ion release and cytotoxicity in Co-Cr-Mo and Ti-Al-V alloy in total knee prosthesis - scanning electron microscopic observation.

Shizuko Ichinose1, Takeshi Muneta, Ichiro Sekiya, Soichiro Itoh, Hideki Aoki, Motoki Tagami.   

Abstract

We surgically retrieved two cobalt(Co)-chromium(Cr)-molybdenum(Mo) and five titanium(Ti)-aluminum(Al)-vanadium(V) alloy knee prostheses from patients because of mechanical failure and pain. We examined the distribution of the small particles which were released from the Co-Cr-Mo and Ti-Al-V alloys using a backscattered scanning electron microscopy (SEM). In addition we analyzed the metals in the artificial knee joints and the tissues adjacent to them using energy dispersive X-ray spectroscopy (EDS). We demonstrated that a myriad of fine particles, produced by the abrasion of both Co-Cr-Mo and Ti-Al-V alloys, accumulated in the synovial cells. As Co-Cr-Mo alloys disintegrate easily in the cells, Co dissolves from the peripheral areas of them, although Cr remains within the cells. In contrast Ti-Al-V alloys are very stable in the synovial cells. From these findings we conclude that the Co-Cr-Mo alloys are hazardous to the body as the alloys release Co which enters the body. In contrast the Ti-Al-V alloys are very stable and are patently safer. Artificial joints, however, are still in considerable need of improvement.

Entities:  

Year:  2003        PMID: 15348542     DOI: 10.1023/a:1021557605458

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  18 in total

1.  Effect of soldering on metal-porcelain bond strength in repaired porcelain-fused-to-metal castings.

Authors:  D F Galindo; C Ercoli; G N Graser; R H Tallents; M E Moss
Journal:  J Prosthet Dent       Date:  2001-01       Impact factor: 3.426

2.  Corrosion of and changes in biological effects of cobalt chrome alloy and 316L stainless steel prosthetic particles with age.

Authors:  D R Haynes; T N Crotti; M R Haywood
Journal:  J Biomed Mater Res       Date:  2000-02

3.  Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings.

Authors:  R M Urban; J J Jacobs; J L Gilbert; J O Galante
Journal:  J Bone Joint Surg Am       Date:  1994-09       Impact factor: 5.284

4.  The effects of proteins on metallic corrosion.

Authors:  G C Clark; D F Williams
Journal:  J Biomed Mater Res       Date:  1982-03

Review 5.  Metal sensitivity reactions to orthopedic implants.

Authors:  K Merritt; S A Brown
Journal:  Int J Dermatol       Date:  1981-03       Impact factor: 2.736

6.  Metal ion release after total hip replacement.

Authors:  H S Dobbs; M J Minski
Journal:  Biomaterials       Date:  1980-10       Impact factor: 12.479

7.  The toxicity of metals used in orthopaedic prostheses. An experimental study using cultured human synovial fibroblasts.

Authors:  T Rae
Journal:  J Bone Joint Surg Br       Date:  1981

8.  Influence of aging heat treatment on mechanical properties of biomedical Ti-Zr based ternary alloys containing niobium.

Authors:  E Kobayashi; H Doi; T Yoneyama; H Hamanaka; I R Gibson; S M Best; J C Shelton; W Bonfield
Journal:  J Mater Sci Mater Med       Date:  1998-11       Impact factor: 3.896

9.  The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.

Authors:  D R Haynes; S D Rogers; S Hay; M J Pearcy; D W Howie
Journal:  J Bone Joint Surg Am       Date:  1993-06       Impact factor: 5.284

10.  Cell damage in vitro following direct contact with fine particles of titanium, titanium alloy and cobalt-chrome-molybdenum alloy.

Authors:  E J Evans
Journal:  Biomaterials       Date:  1994-07       Impact factor: 12.479

View more
  5 in total

1.  Comparative sequential morphological analyses during in vitro chondrogenesis and osteogenesis of mesenchymal stem cells embedded in collagen gels.

Authors:  Shizuko Ichinose; Motoki Tagami; Takeshi Muneta; Hitoshi Mukohyama; Ichiro Sekiya
Journal:  Med Mol Morphol       Date:  2013-01-17       Impact factor: 2.309

2.  Long-term durability of orthodontic mini-implants.

Authors:  Mona Aly Abbassy; Ahmed Samir Bakry; Khalid Hashim Zawawi; Ali Habib Hassan
Journal:  Odontology       Date:  2017-08-24       Impact factor: 2.634

3.  Resin-dentin bonding interface after photochemical surface treatment.

Authors:  Ken-ichi Tonami; Kazunobu Sano; Shizuko Ichinose; Kouji Araki
Journal:  Photomed Laser Surg       Date:  2015-01-02       Impact factor: 2.796

4.  Do 'passive' medical titanium surfaces deteriorate in service in the absence of wear?

Authors:  O Addison; A J Davenport; R J Newport; S Kalra; M Monir; J F W Mosselmans; D Proops; R A Martin
Journal:  J R Soc Interface       Date:  2012-07-25       Impact factor: 4.118

5.  Blood titanium levels in patients with large and sliding titanium implants.

Authors:  Martina Tognini; Harry Hothi; Stewart Tucker; Edel Broomfield; Masood Shafafy; Panos Gikas; Anna Di Laura; Johann Henckel; Alister Hart
Journal:  BMC Musculoskelet Disord       Date:  2022-08-16       Impact factor: 2.562

  5 in total