Literature DB >> 8314823

The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.

D R Haynes1, S D Rogers, S Hay, M J Pearcy, D W Howie.   

Abstract

We investigated the relationship between the toxic effects of metal wear particles and their ability to stimulate the release of inflammatory mediators implicated in bone resorption. In vitro studies were carried out with use of rat peritoneal macrophages, which were exposed to either cobalt-chromium-alloy or titanium-aluminum-vanadium particles, milled from the metal components of hip prostheses. The particles were in the size-range of, and at concentrations similar to, those found in the tissues surrounding failed prostheses in humans. The titanium-aluminum-vanadium particles showed little toxicity even at high concentrations, while the cobalt-chromium particles were very toxic. The titanium-aluminum-vanadium particles induced significantly more release of prostaglandin E2 than did the cobalt-chromium particles, and this was true for a wide range of concentrations. Exposure to titanium-aluminum-vanadium increased the release of prostaglandin E2, interleukin-1, tumor necrosis factor, and interleukin-6. In contrast, exposure to cobalt-chromium particles was associated with a decreased release of prostaglandin E2 and interleukin-6, and it had little effect on the release of interleukin-1 and tumor necrosis factor.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8314823     DOI: 10.2106/00004623-199306000-00004

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  37 in total

1.  Production and distribution of interleukin 15 and its receptors (IL-15Ralpha and IL-R2beta) in the implant interface tissues obtained during revision of failed total joint replacement.

Authors:  S Saeed; P A Revell
Journal:  Int J Exp Pathol       Date:  2001-06       Impact factor: 1.925

2.  Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements.

Authors:  J L Tipper; P J Firkins; E Ingham; J Fisher; M H Stone; R Farrar
Journal:  J Mater Sci Mater Med       Date:  1999-06       Impact factor: 3.896

3.  Surgical variables influence metal ion levels after hip resurfacing.

Authors:  Nicholas M Desy; Stephane G Bergeron; Alain Petit; Olga L Huk; John Antoniou
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

Review 4.  Periprosthetic osteolysis after total hip replacement: molecular pathology and clinical management.

Authors:  Donald W Howie; Susan D Neale; David R Haynes; Oksana T Holubowycz; Margaret A McGee; Lucian B Solomon; Stuart A Callary; Gerald J Atkins; David M Findlay
Journal:  Inflammopharmacology       Date:  2013-10-15       Impact factor: 4.473

5.  Mesenchymal stem cell interaction with ultra-smooth nanostructured diamond for wear-resistant orthopaedic implants.

Authors:  William C Clem; Shafiul Chowdhury; Shane A Catledge; Jeffrey J Weimer; Faheem M Shaikh; Kristin M Hennessy; Valery V Konovalov; Michael R Hill; Alfred Waterfeld; Susan L Bellis; Yogesh K Vohra
Journal:  Biomaterials       Date:  2008-05-19       Impact factor: 12.479

6.  Arthroplasty implant biomaterial particle associated macrophages differentiate into lacunar bone resorbing cells.

Authors:  R Pandey; J Quinn; C Joyner; D W Murray; J T Triffitt; N A Athanasou
Journal:  Ann Rheum Dis       Date:  1996-06       Impact factor: 19.103

Review 7.  Biomaterials for Bone Regenerative Engineering.

Authors:  Xiaohua Yu; Xiaoyan Tang; Shalini V Gohil; Cato T Laurencin
Journal:  Adv Healthc Mater       Date:  2015-04-07       Impact factor: 9.933

Review 8.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

9.  Role of polyethylene particles in peri-prosthetic osteolysis: A review.

Authors:  Gerald J Atkins; David R Haynes; Donald W Howie; David M Findlay
Journal:  World J Orthop       Date:  2011-10-18

10.  Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis.

Authors:  Jean-Yves Lazennec; Patrick Boyer; Joel Poupon; Marc-Antoine Rousseau; Carine Roy; Philippe Ravaud; Yves Catonné
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.