Literature DB >> 8077264

Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings.

R M Urban1, J J Jacobs, J L Gilbert, J O Galante.   

Abstract

Migration of solid corrosion products from the modular head-neck junction of fifteen total hip replacements to the periprosthetic tissues was studied. The devices and tissues were recovered at the time of a revision procedure or at autopsy after a mean of sixty-four months (range, eight to ninety-seven months). The prostheses had a cobalt-chromium-alloy head coupled with a cobalt-chromium-alloy or a titanium-alloy stem. The solid corrosion product was identified by electron microprobe analysis and Fourier transform infrared microprobe spectroscopy as a chromium orthophosphate hydrate-rich material. The product was present at the junction of the modular head and neck and as particles within the periprosthetic tissues as early as eight months postoperatively. In several hips, it was also present on the polyethylene bearing surface. The particles in the tissues ranged in size from less than one to 500 micrometers. They were present within histiocytes or were surrounded by foreign-body giant cells in the pseudocapsule of the hip joint; in the membranes of the femoral bone-implant interface; and at sites of femoral endosteal erosions, with and without loosening of the femoral component.

Entities:  

Mesh:

Year:  1994        PMID: 8077264     DOI: 10.2106/00004623-199409000-00009

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  47 in total

1.  [Proposal for the classification of the periprosthetic membrane from loosened hip and knee endoprostheses].

Authors:  L Morawietz; Th Gehrke; R-A Classen; B Barden; M Otto; T Hansen; Th Aigner; P Stiehl; J Neidel; J H Schröder; L Frommelt; Th Schubert; C Meyer-Scholten; A König; Ph Ströbel; Ch P Rader; S Kirschner; F Lintner; W Rüther; A Skwara; I Bos; J Kriegsmann; V Krenn
Journal:  Pathologe       Date:  2004-09       Impact factor: 1.011

2.  Implications of orthopedic fretting corrosion particles on skeletal muscle microcirculation.

Authors:  C N Kraft; B Burian; O Diedrich; M A Wimmer
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

3.  [Histopathological diagnostics in endoprosthesis loosening].

Authors:  L Morawietz; T Gehrke; J H Schröder; V Krenn
Journal:  Pathologe       Date:  2006-11       Impact factor: 1.011

4.  A New Case of Fracture of a Modular Femoral Neck Device After a Total Hip Arthroplasty.

Authors:  Klemens Trieb; Nicola Stadler
Journal:  Open Orthop J       Date:  2015-05-15

5.  [Histopathological diagnosis of periprosthetic joint infection following total hip arthroplasty : use of a standardized classification system of the periprosthetic interface membrane].

Authors:  M Müller; L Morawietz; O Hasart; P Strube; C Perka; S Tohtz
Journal:  Orthopade       Date:  2009-11       Impact factor: 1.087

Review 6.  What is the trouble with trunnions?

Authors:  Christina I Esposito; Timothy M Wright; Stuart B Goodman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

7.  What is the Diagnostic Accuracy of MRI for Component Loosening in THA?

Authors:  Alissa J Burge; Gabrielle P Konin; Jennifer L Berkowitz; Bin Lin; Matthew F Koff; Hollis G Potter
Journal:  Clin Orthop Relat Res       Date:  2019-09       Impact factor: 4.176

8.  Do Well-functioning THAs Retrieved at Autopsy Exhibit Evidence of Fretting and Corrosion?

Authors:  Jeffrey Lange; Amanda Wach; Chelsea N Koch; Robert H Hopper; Henry Ho; Charles A Engh; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-10       Impact factor: 4.176

Review 9.  Corrosion of Metallic Biomaterials: A Review.

Authors:  Noam Eliaz
Journal:  Materials (Basel)       Date:  2019-01-28       Impact factor: 3.623

10.  A stature-specific concept for uncemented, primary total hip arthroplasty.

Authors:  Georg W Omlor; Hannah Ullrich; Knut Krahmer; Alexander Jung; Günther Aldinger; Peter Aldinger
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.