Literature DB >> 15348538

Wear behavior of carbide coated Co-Cr-Mo implant alloy.

N S Vandamme1, B H Wayman, L D T Topoleski.   

Abstract

The wear behavior of a new type of metal carbide surface coating on Co-Cr-Mo implant alloy was studied. The coating was created using a microwave plasma-assisted reaction. Codeposition of impurity diamond film, diamond particles, and soot was prevented by controlling process conditions. Wear tests were carried out using a sapphire ball-on-Co-Cr-Mo disc unidirectional sliding configuration with harsh conditions of high contact stress and slow sliding speed in both no-lubrication, and deionized water lubrication environments. In the case of uncoated Co-Cr-Mo discs, the effect of deionized water lubrication was remarkable and reduced the wear factor by one order of magnitude compared to the no-lubrication tests. The wear factor of carbide coated Co-Cr-Mo discs was slightly smaller than that of uncoated Co-Cr-Mo discs with deionized water lubrication (2.7 x 10(-6) mm3 N(-1) m(-1) vs. 4.2 x 10(-6) mm3 N(-1) m(-1)). The addition of deionized water lubrication did not greatly affect the wear factor of carbide coated Co-Cr-Mo discs. The influence of surface geometry resulting from the "brain coral-like" surface morphology of carbide layers on wear behavior was analyzed considering stress concentrations and effective contact area.

Entities:  

Year:  2003        PMID: 15348538     DOI: 10.1023/a:1021549403641

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  10 in total

1.  Wear of ultra-high molecular weight polyethylene against damaged and undamaged stainless steel and diamond-like carbon-coated counterfaces.

Authors:  P Firkins; J L Hailey; J Fisher; A H Lettington; R Butter
Journal:  J Mater Sci Mater Med       Date:  1998-10       Impact factor: 3.896

2.  Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements.

Authors:  J L Tipper; P J Firkins; E Ingham; J Fisher; M H Stone; R Farrar
Journal:  J Mater Sci Mater Med       Date:  1999-06       Impact factor: 3.896

3.  The wear behavior of ion-implanted Ti-6A1-4V against UHMW polyethylene.

Authors:  H A McKellop; T V Röstlund
Journal:  J Biomed Mater Res       Date:  1990-11

Review 4.  Clinical reviews: particulate debris and failure of total hip replacements.

Authors:  M Jasty
Journal:  J Appl Biomater       Date:  1993

5.  In vivo wear of three types of metal on metal hip prostheses during two decades of use.

Authors:  H McKellop; S H Park; R Chiesa; P Doorn; B Lu; P Normand; P Grigoris; H Amstutz
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

6.  Engineering issues and wear performance of metal on metal hip implants.

Authors:  F W Chan; J D Bobyn; J B Medley; J J Krygier; S Yue; M Tanzer
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

7.  Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements.

Authors:  M Semlitsch; H G Willert
Journal:  Proc Inst Mech Eng H       Date:  1997       Impact factor: 1.617

Review 8.  Systems view of optimizing metal on metal bearings.

Authors:  J A Schey
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

Review 9.  Mechanism and clinical significance of wear debris-induced osteolysis.

Authors:  H C Amstutz; P Campbell; N Kossovsky; I C Clarke
Journal:  Clin Orthop Relat Res       Date:  1992-03       Impact factor: 4.176

10.  A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.

Authors:  A A Goldsmith; D Dowson; G H Isaac; J G Lancaster
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

  10 in total
  2 in total

1.  Control of surface morphology of carbide coating on Co-Cr-Mo implant alloy.

Authors:  N S Vandamme; L D T Topoleski
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

2.  The effect of 3 wt.% Cu addition on the microstructure, tribological property and corrosion resistance of CoCrW alloys fabricated by selective laser melting.

Authors:  Jiasi Luo; Songquan Wu; Yanjin Lu; Sai Guo; Yang Yang; Chaoqian Zhao; Junjie Lin; Tingting Huang; Jinxin Lin
Journal:  J Mater Sci Mater Med       Date:  2018-03-19       Impact factor: 3.896

  2 in total