Literature DB >> 8981885

Engineering issues and wear performance of metal on metal hip implants.

F W Chan1, J D Bobyn, J B Medley, J J Krygier, S Yue, M Tanzer.   

Abstract

A major concern in total hip arthroplasty is the generation of polyethylene wear particles at the articulating surfaces and resulting macrophage mediated periimplant osteolysis. There is renewed interest in metal on metal bearings as a solution to this problem in view of their potential for greatly improved wear performance. Using a commercially available hip simulator, the wear performance of metal on metal femoral head and acetabular cup combinations was evaluated and various parameters affecting metal on metal implant wear were identified. Nine implants custom manufactured from 2 medical grades of CoCrMo alloy (ASTM F1537-95 and F75-92) were tested within bovine serum as the lubricant to 3 million cycles (equivalent to approximately 3 years of service in vivo). The progressive wear of the components was determined by gravimetric methods at approximately every 300,000 cycles. The wear rates were characterized by an initial period of accelerated wear after which a lower steady state wear rate was observed for subsequent cycles. The presence of calcium phosphate films on the component surfaces, the microstructure of the lower carbon, wrought alloy, and increased effective radii (decreased diametral clearances) were identified as factors that may be favorable to improved wear performance. The extent of the effect on wear of each parameter, however, cannot be discerned at this point and necessitates a study in which parametric changes are more tightly controlled. The present study suggests that the use of metal on metal articulating surfaces may mitigate the problem of osteolysis by offering improved wear performance.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8981885

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  13 in total

Review 1.  Revision arthroplasty: an update.

Authors:  D Williams; A Taylor; P McLardy-Smith
Journal:  Skeletal Radiol       Date:  2009-11       Impact factor: 2.199

2.  The Hard on Hard Bearings in THA - Current concepts.

Authors:  P Gopinathan
Journal:  J Orthop       Date:  2014-09-19

3.  Predictors of participation in sports after hip and knee arthroplasty.

Authors:  Daniel H Williams; Nelson V Greidanus; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  Femoral head size does not affect ion values in metal-on-metal total hips.

Authors:  Mitchell Bernstein; Alan Walsh; Alain Petit; David J Zukor; Olga L Huk; John Antoniou
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

Review 5.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

6.  An initial experience with hip resurfacing versus cementless total hip arthroplasty.

Authors:  Justin Michael Arndt; Glenn D Wera; Victor M Goldberg
Journal:  HSS J       Date:  2013-06-25

7.  Wear behavior of carbide coated Co-Cr-Mo implant alloy.

Authors:  N S Vandamme; B H Wayman; L D T Topoleski
Journal:  J Mater Sci Mater Med       Date:  2003-01       Impact factor: 3.896

8.  Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples.

Authors:  S C Scholes; A Unsworth
Journal:  J Mater Sci Mater Med       Date:  2001-04       Impact factor: 3.896

9.  Cytotoxic and apoptotic effects of cobalt and chromium ions on J774 macrophages - Implication of caspase-3 in the apoptotic pathway.

Authors:  I Catelas; A Petit; D J Zukor; O L Huk
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

10.  In vitro corrosion testing of PVD coatings applied to a surgical grade Co-Cr-Mo alloy.

Authors:  J Bolton; X Hu
Journal:  J Mater Sci Mater Med       Date:  2002-06       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.