Literature DB >> 15338418

Auto-SENSE view-sharing cine cardiac imaging.

H Köstler1, M Beer, C Ritter, D Hahn, J Sandstede.   

Abstract

Cardiac MR cine imaging during breath hold is a compromise between spatial and temporal resolution and duration of breath hold. Especially for sick patients who have problems holding their breath, a short acquisition time is mandatory for all sequences. A combination of Auto-SENSE parallel imaging and view-sharing was implemented for fast cine imaging of the human heart and applied to healthy volunteers. Compared to conventional Fourier imaging, data acquisition could be accelerated by a factor of 3.6. Neither a pre-scan nor additional lines in k-space are required to generate the sensitivity maps in Auto-SENSE.

Entities:  

Mesh:

Year:  2004        PMID: 15338418     DOI: 10.1007/s10334-004-0047-7

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  12 in total

1.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE).

Authors:  P Kellman; F H Epstein; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

2.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

4.  MR Imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters.

Authors:  Stephan Miller; Orlando P Simonetti; James Carr; Ulrich Kramer; J Paul Finn
Journal:  Radiology       Date:  2002-04       Impact factor: 11.105

5.  VD-AUTO-SMASH imaging.

Authors:  R M Heidemann; M A Griswold; A Haase; P M Jakob
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

6.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

7.  Auto-SENSE perfusion imaging of the whole human heart.

Authors:  Herbert Köstler; Jörn J W Sandstede; Claudia Lipke; Wilfried Landschütz; Meinrad Beer; Dietbert Hahn
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

8.  k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

9.  MR fluoroscopy: technical feasibility.

Authors:  S J Riederer; T Tasciyan; F Farzaneh; J N Lee; R C Wright; R J Herfkens
Journal:  Magn Reson Med       Date:  1988-09       Impact factor: 4.668

10.  Correction of spatially dependent phase shifts for partial Fourier imaging.

Authors:  J R MacFall; N J Pelc; R M Vavrek
Journal:  Magn Reson Imaging       Date:  1988 Mar-Apr       Impact factor: 2.546

View more
  1 in total

1.  Parallel acquisition for effective density weighted imaging: PLANED imaging.

Authors:  Oliver M Geier; Dietbert Hahn; Herbert Köstler
Journal:  MAGMA       Date:  2007-01-20       Impact factor: 2.310

  1 in total