Literature DB >> 15330020

Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up.

G Petrou1, H Petrou, C Tilkeridis, T Stavrakis, T Kapetsis, N Kremmidas, M Gavras.   

Abstract

We reviewed 100 cemented Endo-model rotating-hinge (Waldemar Link GMBH & Co, Hamburg, Germany) total knee replacements in 80 patients with a mean age of 70 years (56 to 85) at a mean post-operative follow-up of 11 years (7 to 15). Good or excellent results were seen in 91% of knees and survival at 15 years was 96.1%. There were two deep infections, one dislocation and one supracondylar fracture. There were no peri-operative deaths and there was no loosening, malalignment, migration or wear. We consider this prosthesis to be ideally suited for the replacement of the deformed knee when the use of an unconstrained design may be questionable.

Entities:  

Mesh:

Year:  2004        PMID: 15330020     DOI: 10.1302/0301-620x.86b6.14708

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  35 in total

Review 1.  How to read a postoperative knee replacement radiograph.

Authors:  Nawfal Al-Hadithy; Madhavan C Papanna; Sana Farooq; Yegappan Kalairajah
Journal:  Skeletal Radiol       Date:  2011-10-16       Impact factor: 2.199

2.  Case report: Failure of rotating-hinge total knee prosthesis by disengagement of the hinge-post extension.

Authors:  Debdut Biswas; Bryan Haughom; Robert E Mayle; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2012-12-11       Impact factor: 4.176

3.  Computer-assisted navigation is beneficial both in primary and revision surgery with modular rotating-hinge knee arthroplasty.

Authors:  Björn G Ochs; Anna J Schreiner; Peter M de Zwart; Ulrich Stöckle; Christoph Emanuel Gonser
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-20       Impact factor: 4.342

Review 4.  Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature.

Authors:  Joerg Friesenbichler; Ran Schwarzkopf; Patrick Sadoghi; Scott E Marwin; Mathias Glehr; Werner Maurer-Ertl; Andreas Leithner
Journal:  Int Orthop       Date:  2011-12-28       Impact factor: 3.075

5.  Unicompartmental versus total knee arthroplasty database analysis: is there a winner?

Authors:  Matthew C Lyons; Steven J MacDonald; Lyndsay E Somerville; Douglas D Naudie; Richard W McCalden
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

6.  Good clinical and radiological results of total knee arthroplasty using varus valgus constrained or rotating hinge implants in ligamentous laxity.

Authors:  Eric Röhner; Kathrin Benad; Timo Zippelius; Nadja Kloss; Benjamin Jacob; Julia Kirschberg; Georg Matziolis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-11-20       Impact factor: 4.342

7.  Mid-term survival following primary hinged total knee replacement is good irrespective of the indication for surgery.

Authors:  Paul Baker; Rebecca Critchley; Andrew Gray; Simon Jameson; Paul Gregg; Andrew Port; David Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-14       Impact factor: 4.342

8.  Hinged total knee arthroplasty in the presence of ligamentous deficiency.

Authors:  Daniel Hernández-Vaquero; Manuel A Sandoval-García
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

9.  [Special prosthesis implant with partial femoral replacement. Operation after periprosthetic femoral fracture and ipsilateral long-stem knee prosthesis and fixed-angle osteosynthesis].

Authors:  C Herren; M J Ringe; U Rietkötter; R Sobottke; J Siewe; M Graf
Journal:  Unfallchirurg       Date:  2014-08       Impact factor: 1.000

10.  Loss of distal femur combined with popliteal artery occlusion: reconstructive arthroplasty using modular segmental endoprosthesis: a case report.

Authors:  Shin-Taeg Kang; Chan-Ha Hwang; Bo-Hyeon Kim; Byung-Yoon Sung
Journal:  J Korean Med Sci       Date:  2009-04-20       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.