Literature DB >> 15324759

ODIN-object-oriented development interface for NMR.

Thies H Jochimsen1, Michael von Mengershausen.   

Abstract

A cross-platform development environment for nuclear magnetic resonance (NMR) experiments is presented. It allows rapid prototyping of new pulse sequences and provides a common programming interface for different system types. With this object-oriented interface implemented in C++, the programmer is capable of writing applications to control an experiment that can be executed on different measurement devices, even from different manufacturers, without the need to modify the source code. Due to the clear design of the software, new pulse sequences can be created, tested, and executed within a short time. To post-process the acquired data, an interface to well-known numerical libraries is part of the framework. This allows a transparent integration of the data processing instructions into the measurement module. The software focuses mainly on NMR imaging, but can also be used with limitations for spectroscopic experiments. To demonstrate the capabilities of the framework, results of the same experiment, carried out on two NMR imaging systems from different manufacturers are shown and compared with the results of a simulation.

Entities:  

Mesh:

Year:  2004        PMID: 15324759     DOI: 10.1016/j.jmr.2004.05.021

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  20 in total

1.  Quantifying venous flow dynamics by flow-dephased and flow-rephased functional magnetic resonance imaging.

Authors:  Thies H Jochimsen; Harald E Möller
Journal:  MAGMA       Date:  2005-11-23       Impact factor: 2.310

2.  A powerful graphical pulse sequence programming tool for magnetic resonance imaging.

Authors:  Shen Jie; Liu Ying; Li Jianqi; Li Gengying
Journal:  MAGMA       Date:  2005-12-21       Impact factor: 2.310

3.  The influence of noise on BOLD-mediated vessel size imaging analysis methods.

Authors:  Michael A Germuska; James A Meakin; Daniel P Bulte
Journal:  J Cereb Blood Flow Metab       Date:  2013-08-14       Impact factor: 6.200

4.  Transients may occur in functional magnetic resonance imaging without physiological basis.

Authors:  Ville Renvall; Riitta Hari
Journal:  Proc Natl Acad Sci U S A       Date:  2009-11-16       Impact factor: 11.205

5.  Effects of air susceptibility on proton resonance frequency MR thermometry.

Authors:  Markus N Streicher; Andreas Schäfer; Enrico Reimer; Bibek Dhital; Robert Trampel; Dimo Ivanov; Robert Turner
Journal:  MAGMA       Date:  2011-04-10       Impact factor: 2.310

6.  Poster Viewing Sessions PA00-A01 to PA00-A49.

Authors: 
Journal:  J Cereb Blood Flow Metab       Date:  2019-07       Impact factor: 6.200

7.  MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research: Computer models that take account of body movements promise to provide evaluation and improvement of medical imaging devices and technology.

Authors:  W Paul Segars; Benjamin M W Tsui
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2009-12       Impact factor: 10.961

8.  Pulse sequence programming in a dynamic visual environment: SequenceTree.

Authors:  Jeremy F Magland; Cheng Li; Michael C Langham; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2015-03-07       Impact factor: 4.668

9.  A Web-Based Educational Magnetic Resonance Simulator: Design, Implementation and Testing.

Authors:  Daniel Treceño-Fernández; Juan Calabia-Del-Campo; Miguel L Bote-Lorenzo; Eduardo Gómez Sánchez; Rodrigo de Luis-García; Carlos Alberola-López
Journal:  J Med Syst       Date:  2019-12-02       Impact factor: 4.460

10.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

View more