Literature DB >> 23942365

The influence of noise on BOLD-mediated vessel size imaging analysis methods.

Michael A Germuska1, James A Meakin, Daniel P Bulte.   

Abstract

Vessel size imaging (VSI) is a magnetic resonance imaging (MRI) technique that aims to provide quantitative measurements of tissue microvasculature. An emerging variation of this technique uses the blood oxygenation level-dependent (BOLD) effect as the source of the imaging contrast. Gas challenges have the advantage over contrast injection techniques in that they are noninvasive and easily repeatable because of the fast washout of the contrast. However, initial results from BOLD-VSI studies are somewhat contradictory, with substantially different estimates of the mean vessel radius. Owing to BOLD-VSI being an emerging technique, there is not yet a standard processing methodology, and different techniques have been used to calculate the mean vessel radius and reject uncertain estimates. In addition, the acquisition methodology and signal modeling vary from group to group. Owing to these differences, it is difficult to determine the source of this variation. Here we use computer modeling to assess the impact of noise on the accuracy and precision of different BOLD-VSI calculations. Our results show both potential overestimates and underestimates of the mean vessel radius, which is confirmed with a validation study at 3T.

Mesh:

Substances:

Year:  2013        PMID: 23942365      PMCID: PMC3851896          DOI: 10.1038/jcbfm.2013.141

Source DB:  PubMed          Journal:  J Cereb Blood Flow Metab        ISSN: 0271-678X            Impact factor:   6.200


  29 in total

1.  Vessel size imaging using low intravascular contrast agent concentrations.

Authors:  I Troprès; L Lamalle; R Farion; C Segebarth; C Rémy
Journal:  MAGMA       Date:  2004-12-01       Impact factor: 2.310

2.  Increasing specificity in functional magnetic resonance imaging by estimation of vessel size based on changes in blood oxygenation.

Authors:  Thies H Jochimsen; Harald E Möller
Journal:  Neuroimage       Date:  2007-11-12       Impact factor: 6.556

3.  Oxygenation and hematocrit dependence of transverse relaxation rates of blood at 3T.

Authors:  Jason M Zhao; Chekesha S Clingman; M Johanna Närväinen; Risto A Kauppinen; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2007-09       Impact factor: 4.668

4.  Whole-brain mapping of venous vessel size in humans using the hypercapnia-induced BOLD effect.

Authors:  Thies H Jochimsen; Dimo Ivanov; Derek V M Ott; Wolfgang Heinke; Robert Turner; Harald E Möller; Jürgen R Reichenbach
Journal:  Neuroimage       Date:  2010-02-24       Impact factor: 6.556

5.  Vessel size imaging in humans.

Authors:  V G Kiselev; R Strecker; S Ziyeh; O Speck; J Hennig
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

6.  Magnetic resonance imaging of the mean venous vessel size in the human brain using transient hyperoxia.

Authors:  Yuji Shen; Trevor Ahearn; Matthew Clemence; Christian Schwarzbauer
Journal:  Neuroimage       Date:  2011-01-09       Impact factor: 6.556

7.  Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI.

Authors:  Hanzhang Lu; Yulin Ge
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

8.  [Study of a brain microcirculation in cranioencephalic trauma using the Side Stream Field (SDF) system].

Authors:  Jon Pérez-Bárcena; Javier Ibáñez; Marta Brell; Pedro Llinás; Josep Maria Abadal; Juan Antonio Llompart-Pou
Journal:  Med Intensiva       Date:  2009 Jun-Jul       Impact factor: 2.491

9.  Quantitative evaluation of microvascular density after stroke in rats using MRI.

Authors:  Asamoah Bosomtwi; Quan Jiang; Guang L Ding; Li Zhang; Zheng G Zhang; Mei Lu; James R Ewing; Michael Chopp
Journal:  J Cereb Blood Flow Metab       Date:  2008-09-03       Impact factor: 6.200

10.  Vessel size imaging using dual contrast agent injections.

Authors:  Yuan-Yu Hsu; Wei-Shan Yang; Kun-Eng Lim; Ho-Ling Liu
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

View more
  3 in total

Review 1.  Vessel caliber--a potential MRI biomarker of tumour response in clinical trials.

Authors:  Kyrre E Emblem; Christian T Farrar; Elizabeth R Gerstner; Tracy T Batchelor; Ronald J H Borra; Bruce R Rosen; A Gregory Sorensen; Rakesh K Jain
Journal:  Nat Rev Clin Oncol       Date:  2014-08-12       Impact factor: 66.675

Review 2.  Advances in translational imaging of the microcirculation.

Authors:  Marie Guerraty; Akanksha Bhargava; Janaka Senarathna; Asher A Mendelson; Arvind P Pathak
Journal:  Microcirculation       Date:  2021-03-13       Impact factor: 2.679

3.  Simulations of the effect of diffusion on asymmetric spin echo based quantitative BOLD: An investigation of the origin of deoxygenated blood volume overestimation.

Authors:  Alan J Stone; Naomi C Holland; Avery J L Berman; Nicholas P Blockley
Journal:  Neuroimage       Date:  2019-07-19       Impact factor: 6.556

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.