Literature DB >> 15316760

Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary results.

R Degeorges1, J Parasie, D Mitton, N Imbert, J-N Goubier, F Lavaste.   

Abstract

Longitudinal axial rotations of phalanges during flexion motions of digits have scarcely been analyzed with current anatomical or radiological methods. Recent optoelectronic systems were developed for three-dimensional (3D) kinematic analysis of human motion. These systems have the advantages of being non-invasive and non-irradiating. The current study was based on the VICON optoelectronic system. A validation of the protocol was made among a sample of volunteers for further direct clinical applications. An experimental protocol was set up with adaptations to the requirements of finger analyses (multiple infrared markers inside small-sized capture volumes). The set-up and the protocol details are described. Kinematic studies consisted in recording the movements of the right hand of six volunteers (free from any visible pathology). Results were displayed for the joints of each three-joint finger with calculation of 3D rotations. Metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) flexion angles ranged from 78 degrees to 118 degrees, 72 degrees to 119 degrees and 9 degrees to 66 degrees respectively. Lateral angles ranged from 5 degrees to 39 degrees (MCP), 4 degrees to 39 degrees (PIP) and 4 degrees to 30 degrees (DIP). Mean longitudinal axial rotations of MCP, PIP and DIP joints ranged from 11 degrees pronation to 26 degrees supination. The index finger was in a global pronation position (five of the six specimens). The fourth and fifth fingers were in a global supination position in every case. The third finger was in a more variable global rotation (pronation in four of the six specimens). An experimental protocol using an optoelectronic system (VICON) has been developed for a kinematic analysis of three-joint finger. A global measure study should be initiated among a wider sample of adults. A database should be created with direct clinical applications. Patients' kinematic deficits could be graded either for standard movements (flexion/extension and abduction/adduction) or for longitudinal axial rotations.

Entities:  

Mesh:

Year:  2004        PMID: 15316760     DOI: 10.1007/s00276-004-0277-4

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  24 in total

1.  Measurement of external three-dimensional interphalangeal loads applied during activities of daily living.

Authors:  N K Fowler; A C Nicol
Journal:  Clin Biomech (Bristol, Avon)       Date:  1999-11       Impact factor: 2.063

2.  Rectifying postures reconstructed from joint angles to meet constraints.

Authors:  J J Faraway; X Zhang; D B Chaffin
Journal:  J Biomech       Date:  1999-07       Impact factor: 2.712

3.  The use of the motion analysis system for evaluation of loss of movement in the finger.

Authors:  H Y Chiu; S C Lin; F C Su; S T Wang; H Y Hsu
Journal:  J Hand Surg Br       Date:  2000-04

4.  Three-dimensional metacarpophalangeal joint kinematics using two markers on the phalanx.

Authors:  A D Speirs; C F Small; J T Bryant; D R Pichora; B Y Zee
Journal:  Proc Inst Mech Eng H       Date:  2001       Impact factor: 1.617

5.  The motion analysis system and the fingertip motion area. Normal values in young adults.

Authors:  H Y Chiu; F C Su; S T Wang
Journal:  J Hand Surg Br       Date:  1998-02

6.  Passive axial rotation of the metacarpophalangeal joint.

Authors:  J Krishnan; L Chipchase
Journal:  J Hand Surg Br       Date:  1997-04

7.  Optimized 3D coordinate reconstruction from paired stereographs using a calibrated phantom.

Authors:  C F Small; J T Bryant
Journal:  J Biomed Eng       Date:  1993-03

8.  Stereoradiogrammetric technique for estimating alignment of the joints in the hand and wrist.

Authors:  R J Runciman; J T Bryant; C F Small; N Fujita; T D Cooke
Journal:  J Biomed Eng       Date:  1993-03

9.  Quantitative analysis of the linkage between the interphalangeal joints of the index finger. An in vivo study.

Authors:  P Hahn; H Krimmer; A Hradetzky; U Lanz
Journal:  J Hand Surg Br       Date:  1995-10

10.  Measurement of three-joint-finger motions: reality or fancy? A three-dimensional anatomical approach.

Authors:  R Degeorges; C Oberlin
Journal:  Surg Radiol Anat       Date:  2003-05-20       Impact factor: 1.246

View more
  9 in total

1.  Robust identification of three-dimensional thumb and index finger kinematics with a minimal set of markers.

Authors:  Raviraj Nataraj; Zong-Ming Li
Journal:  J Biomech Eng       Date:  2013-09       Impact factor: 2.097

2.  A digit alignment device for kinematic analysis of the thumb and index finger.

Authors:  Zhilei Liu Shen; Tracy A Mondello; Raviraj Nataraj; Mathieu F Domalain; Zong-Ming Li
Journal:  Gait Posture       Date:  2012-05-23       Impact factor: 2.840

3.  Curvatures of the DIP joints of the hand.

Authors:  Kraig S Graham; Robert J Goitz; Robert A Kaufmann
Journal:  Hand (N Y)       Date:  2014-12

4.  Multi-finger coordination in healthy subjects and stroke patients: a mathematical modelling approach.

Authors:  Ilaria Carpinella; Johanna Jonsdottir; Maurizio Ferrarin
Journal:  J Neuroeng Rehabil       Date:  2011-04-20       Impact factor: 4.262

Review 5.  Ergonomic evaluation of biomechanical hand function.

Authors:  Kyung-Sun Lee; Myung-Chul Jung
Journal:  Saf Health Work       Date:  2014-09-22

6.  A Two-Axis Goniometric Sensor for Tracking Finger Motion.

Authors:  Lefan Wang; Turgut Meydan; Paul Ieuan Williams
Journal:  Sensors (Basel)       Date:  2017-04-05       Impact factor: 3.576

7.  Motion video-based quantitative analysis of the 'lifting-thrusting' method: a comparison between teachers and students of acupuncture.

Authors:  Wen-Chao Tang; Hua-Yuan Yang; Tang-Yi Liu; Ming Gao; Gang Xu
Journal:  Acupunct Med       Date:  2017-08-26       Impact factor: 2.267

8.  Differences in EMG Burst Patterns During Grasping Dexterity Tests and Activities of Daily Living.

Authors:  Jen Rowson; Alaster Yoxall; Victor Gonzalez
Journal:  Front Bioeng Biotechnol       Date:  2018-05-25

9.  Minimal detectable difference of the finger and wrist range of motion: comparison of goniometry and 3D motion analysis.

Authors:  Lisa Reissner; Gabriella Fischer; Renate List; William R Taylor; Pietro Giovanoli; Maurizio Calcagni
Journal:  J Orthop Surg Res       Date:  2019-06-10       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.