Literature DB >> 12756500

Measurement of three-joint-finger motions: reality or fancy? A three-dimensional anatomical approach.

R Degeorges1, C Oberlin.   

Abstract

Various anatomical publications have reported two-dimensional studies with flexion/extension or abduction/adduction motion analysis, but longitudinal axial rotations (LAR) of three-joint fingers have rarely been mentioned. The aim of our study was to determine the maximal passive motions of three-joint-fingers and to measure the passive LAR of phalanges during a flexion/extension movement. A protocol of anatomical dissection was carried out with 22 fresh-frozen limbs from 11 human cadavers free from any visible pathology. The sample consisted of six females and five males with a mean age of 75.7 years (range 65-94 years). Passive motions of fingers excluding the thumb were analyzed with a wire circling technique. Extreme flexion/extension angles and adduction/abduction laxities were measured for each joint. LAR angles of distal bony segment position were evaluated in comparison with the proximal bony segment position in extreme flexion or extension. The results were recorded for the joints of each three-joint-finger. No difference was statistically related to sex or right/left-sided criteria ( p>0.05). Passive LARs were measured in spite of an aggressive anatomical protocol. A small database was set up. LARs were an important third type of motion. They should be analyzed during a routine clinical examination of patients' hands as well as flexion/extension or abduction/adduction motions.

Entities:  

Mesh:

Year:  2003        PMID: 12756500     DOI: 10.1007/s00276-003-0104-3

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  28 in total

1.  A three-dimensional definition for the flexion/extension and abduction/adduction angles.

Authors:  P L Cheng; M Pearcy
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

2.  Three-dimensional metacarpophalangeal joint kinematics using two markers on the phalanx.

Authors:  A D Speirs; C F Small; J T Bryant; D R Pichora; B Y Zee
Journal:  Proc Inst Mech Eng H       Date:  2001       Impact factor: 1.617

3.  Visual estimation of finger angles: do we need goniometers?

Authors:  V Rose; C C Nduka; J A Pereira; M A Pickford; H J C R Belcher
Journal:  J Hand Surg Br       Date:  2002-08

4.  Anatomy of the joints of the fingers.

Authors:  S M Craig
Journal:  Hand Clin       Date:  1992-11       Impact factor: 1.907

5.  Digital ranges of motion: normal values in young adults.

Authors:  W J Mallon; H R Brown; J A Nunley
Journal:  J Hand Surg Am       Date:  1991-09       Impact factor: 2.230

6.  Ranges of joint motion of the adult hand.

Authors:  B Skvarilová; A Plevková
Journal:  Acta Chir Plast       Date:  1996

7.  Passive axial rotation of the metacarpophalangeal joint.

Authors:  J Krishnan; L Chipchase
Journal:  J Hand Surg Br       Date:  1997-04

8.  Optimized 3D coordinate reconstruction from paired stereographs using a calibrated phantom.

Authors:  C F Small; J T Bryant
Journal:  J Biomed Eng       Date:  1993-03

9.  Stereoradiogrammetric technique for estimating alignment of the joints in the hand and wrist.

Authors:  R J Runciman; J T Bryant; C F Small; N Fujita; T D Cooke
Journal:  J Biomed Eng       Date:  1993-03

10.  A method of two-dimensional measurement for evaluating finger motion impairment. A description of the method and comparison with angular measurement.

Authors:  H Y Chiu
Journal:  J Hand Surg Br       Date:  1995-10
View more
  4 in total

1.  Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary results.

Authors:  R Degeorges; J Parasie; D Mitton; N Imbert; J-N Goubier; F Lavaste
Journal:  Surg Radiol Anat       Date:  2004-08-13       Impact factor: 1.246

2.  Rotations of three-joint fingers: a radiological study.

Authors:  R Degeorges; S Laporte; E Pessis; D Mitton; J N Goubier; F Lavaste
Journal:  Surg Radiol Anat       Date:  2004-10       Impact factor: 1.246

Review 3.  Ergonomic evaluation of biomechanical hand function.

Authors:  Kyung-Sun Lee; Myung-Chul Jung
Journal:  Saf Health Work       Date:  2014-09-22

4.  Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography.

Authors:  Satoshi Shimawaki; Takuma Murai; Masataka Nakabayashi; Hideharu Sugimoto
Journal:  Appl Bionics Biomech       Date:  2019-01-06       Impact factor: 1.781

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.