OBJECTIVE: To measure the external three-dimensional loads applied to the interphalangeal joints during activities of daily living.
DESIGN: A six-degree-of-freedom force transducer was used in conjunction with motion analysis studies.
BACKGROUND: There is a lack of accurate three-dimensional load data available for input into biomechanical models of the hand.
METHODS: A new force transducer has been incorporated into several housings representing objects in domestic use: a jar, a tap, a key in a lock and a jug kettle. Three-dimensional kinematic data were acquired using a six-camera VICON motion analysis system. Twelve healthy volunteers took part in the study, which compared power and precision grips in 'opening' and 'closing' activities.
RESULTS: Large external forces and moments are applied to the middle and distal phalanges in sagittal, coronal and axial directions. Average inter-segmental forces of up to 25 N and average moments of up to 1.8 Nm are experienced at the proximal interphalangeal joint.
CONCLUSIONS: The results show that complex loading patterns are associated with routine activities of daily living. RELEVANCE: Biomechanical models of the interphalangeal joints are limited in their ability to accurately predict tendon and joint forces by the quality of the input data obtained by conventional measurement techniques. Models have tended to rely on hypothetical values of external forces acting on the hand and are over-simplified or limited to two-dimensions. The results from the current study challenge the validity of these simplified models and offer a more complete picture of the complex loading system applied to the finger during daily life.

Entities:  

Mesh:

Year:  1999        PMID: 10521648     DOI: 10.1016/s0268-0033(99)00016-9

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  7 in total

1.  Multi-digit maximum voluntary torque production on a circular object.

Authors:  Jae Kun Shim; Junfeng Huang; Alexander W Hooke; Mark L Latsh; Vladimir M Zatsiorsky
Journal:  Ergonomics       Date:  2007-05       Impact factor: 2.778

2.  Distal interphalangeal joint arthrodesis with nonaxial multiple small screws: a biomechanical analysis with axial headless compression screw and clinical result of 15 consecutive cases.

Authors:  Seung Hun Woo; Sang Ho Kwak; Hyo Seok Jang; Dong Hee Kim; Jang Hyeon Seo; Sang Hyun Lee
Journal:  BMC Musculoskelet Disord       Date:  2022-05-27       Impact factor: 2.562

3.  Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary results.

Authors:  R Degeorges; J Parasie; D Mitton; N Imbert; J-N Goubier; F Lavaste
Journal:  Surg Radiol Anat       Date:  2004-08-13       Impact factor: 1.246

Review 4.  Proximal Phalanx Fracture Management.

Authors:  Tim T Lögters; Hannah H Lee; Sebastian Gehrmann; Joachim Windolf; Robert A Kaufmann
Journal:  Hand (N Y)       Date:  2017-10-27

5.  Integration of marker and force data to compute three-dimensional joint moments of the thumb and index finger digits during pinch.

Authors:  Raviraj Nataraj; Zong-Ming Li
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-08-15       Impact factor: 1.763

6.  Development, construct validity, and reproducibility of a mimetic sealed jar measuring the dynamics of opening.

Authors:  Arin M Ellingson; Corey McGee; David J Nuckley; Michelle Ferkul; Virgil G Mathiowetz
Journal:  J Rehabil Assist Technol Eng       Date:  2017-02-01

7.  Wearable strain gauge-based technology measures manual tactile forces during the activities of daily living.

Authors:  Michael Riddle; Kevin MacDermid-Watts; Sara Holland; Joy C MacDermid; Emily Lalone; Louis Ferreira
Journal:  J Rehabil Assist Technol Eng       Date:  2018-11-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.