Literature DB >> 8543884

Quantitative analysis of the linkage between the interphalangeal joints of the index finger. An in vivo study.

P Hahn1, H Krimmer, A Hradetzky, U Lanz.   

Abstract

We have established a simple method of measuring joint motion under physiological conditions. For this purpose we use an ultrasound measuring system employing marker points consisting of miniaturized ultrasound transmitters. This device was tested on a simple biomechanical model, the linkage of the proximal and distal interphalangeal joints. The angles of these joints were recorded during opening and closing of the fist in 34 index fingers of 17 healthy persons. The results of the measurements were plotted on a rectangular coordinate system. Analysis showed an approximately linear linkage between the IP joints of the index finger. The curve for extension was the same as that for flexion. The linkage varies greatly. On average 1 degree of PIP joint flexion is equivalent to 0.76 degree of DIP joint flexion. Our study showed no significant difference between the dominant and non-dominant hand. The results showed that there is a linear linkage between the proximal and distal interphalangeal joints, which is equal for flexion and extension.

Entities:  

Mesh:

Year:  1995        PMID: 8543884     DOI: 10.1016/s0266-7681(05)80139-1

Source DB:  PubMed          Journal:  J Hand Surg Br        ISSN: 0266-7681


  7 in total

1.  [Aspects of finger mobility].

Authors:  J Koebke
Journal:  Orthopade       Date:  2008-12       Impact factor: 1.087

2.  Trajectory of the index finger during grasping.

Authors:  Jason Friedman; Tamar Flash
Journal:  Exp Brain Res       Date:  2009-06-12       Impact factor: 1.972

3.  A Novel Clinical-Driven Design for Robotic Hand Rehabilitation: Combining Sensory Training, Effortless Setup, and Large Range of Motion in a Palmar Device.

Authors:  Raphael Rätz; François Conti; René M Müri; Laura Marchal-Crespo
Journal:  Front Neurorobot       Date:  2021-12-20       Impact factor: 2.650

4.  Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary results.

Authors:  R Degeorges; J Parasie; D Mitton; N Imbert; J-N Goubier; F Lavaste
Journal:  Surg Radiol Anat       Date:  2004-08-13       Impact factor: 1.246

5.  A soft stretchable bending sensor and data glove applications.

Authors:  Zhong Shen; Juan Yi; Xiaodong Li; Mark Hin Pei Lo; Michael Z Q Chen; Yong Hu; Zheng Wang
Journal:  Robotics Biomim       Date:  2016-12-01

6.  Studying kinematic linkage of finger joints: estimation of kinematics of distal interphalangeal joints during manipulation.

Authors:  Alba Roda-Sales; Joaquín L Sancho-Bru; Margarita Vergara
Journal:  PeerJ       Date:  2022-10-04       Impact factor: 3.061

7.  Configuration Synthesis and Performance Analysis of Finger Soft Actuator.

Authors:  Ziqiang Zhang; Hanlong Chen; Zining Zhang
Journal:  Appl Bionics Biomech       Date:  2018-08-14       Impact factor: 1.781

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.