Literature DB >> 15304660

Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience.

Cheng Hong1, George S Chrysant, Pamela K Woodard, Kyongtae T Bae.   

Abstract

The authors investigated the contrast enhancement characteristics of the coronary artery stent lumen to assess patency and then evaluated the accuracy of computed tomographic (CT) measurement of the in-stent luminal diameter. Nineteen patients (16 men and three women; mean age, 58.7 years) with 26 stents underwent cardiac-gated CT angiography with a 16-detector row scanner 1-3 weeks after stent placement. CT images depicted the lumina of 20 stents in 14 patients. CT attenuation measured in the treated lumen was higher than, and correlated highly (r >/= 0.87) with, attenuation in the proximal and distal untreated lumen. Estimated values for in-stent luminal diameter were lower with CT than with conventional angiography (P <.001), and the mean error (16.1%) that resulted from estimation based on sharp-kernel CT images was significantly smaller than that (27.3%) from estimation based on medium-smooth-kernel CT images (P <.001). Visualization of the in-stent lumen at CT angiography with a 16-detector row scanner allows assessment of coronary artery stent patency on the basis of measured contrast enhancement. Copyright RSNA, 2004

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15304660     DOI: 10.1148/radiol.2331031564

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  18 in total

1.  Computed Tomography Angiography of Carotid Stent. Comparison of Various Self-expandable Stent in a Phantom Model.

Authors:  C Sakai; N Sakai; T Okada; T Kuroiwa; H Ishihara; A Morizane; T Yano; H Kikuchi
Journal:  Interv Neuroradiol       Date:  2006-06-15       Impact factor: 1.610

2.  Comparative analysis between 64- and 320-slice spiral computed tomography in the display of coronary artery stents and diagnosis of in-stent restenosis.

Authors:  Junyan Yue; Jie Chen; Wenguang Dou; Ying Hu; Qiang Li; Fengmei Zhou; Hongkai Cui; Qingwu Wu; Ruimin Yang
Journal:  Exp Ther Med       Date:  2015-09-23       Impact factor: 2.447

3.  Evaluation of in-stent restenosis in proximal coronary arteries with multidetector computed tomography (MDCT).

Authors:  V Chabbert; D Carrie; M Bennaceur; E Maupas; V Lauwers; M Mhem; T Lhermusier; M Elbaz; F Joffre; H Rousseau; J Puel
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

4.  Use of high-resolution spiral CT for the diagnosis of coronary artery disease.

Authors:  Willem B Meijboom; Niels van Pelt; Pim de Feyter
Journal:  Curr Treat Options Cardiovasc Med       Date:  2007-02

5.  Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography.

Authors:  Tiziano Schepis; Pascal Koepfli; Sebastian Leschka; Lotus Desbiolles; Lars Husmann; Oliver Gaemperli; Franz R Eberli; Simon Wildermuth; Borut Marincek; Thomas F Lüscher; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

6.  In vitro evaluation of coronary stents and in-stent stenosis using a dynamic cardiac phantom and a 64-detector row CT scanner.

Authors:  T Schlosser; T Scheuermann; S Ulzheimer; O K Mohrs; M Kühling; P E Albrecht; T Voigtländer; J Barkhausen; A Schmermund
Journal:  Clin Res Cardiol       Date:  2007-08-21       Impact factor: 5.460

7.  64 Slice multi-detector row cardiac CT.

Authors:  Harpreet K Pannu; Pamela T Johnson; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2008-10-22

8.  Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings.

Authors:  Martin Heuschmid; Benjamin Wiesinger; Gunnar Tepe; Oliver Luz; Andreas F Kopp; Claus D Claussen; Stephan H Duda
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

9.  Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

Authors:  Joelle M Kefer; Emmanuel Coche; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

10.  Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT.

Authors:  David Maintz; Matthias C Burg; Harald Seifarth; Alexander C Bunck; Murat Ozgün; Roman Fischbach; Kai Uwe Jürgens; Walter Heindel
Journal:  Eur Radiol       Date:  2008-08-06       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.