Literature DB >> 15292960

[Treatment of dislocated 3- and 4-part fractures of the proximal humerus with an angle-stabilizing fixation plate].

R Hente1, J Kampshoff, B Kinner, B Füchtmeier, M Nerlich.   

Abstract

In the presented prospective study 35 consecutive patients with displaced 3- and 4-part fractures of the proximal humerus, including fracture dislocations, were treated with a fixator plate comprising angular stability between May 2001 and December 2002. After 18.5 (8-29) months 31 (89%) fractures were available for follow-up. Good and very good results were obtained in 64%. A poor result was documented in 23%. 64% of the patients had no or mild pain, 71% were able to abduct the arm over 90 degrees . Fracture classification according to Neer and AO had no influence on the outcome, with a mean Constant Score of 76 points. Partial avascular necrosis (AVN) of the humeral head was seen in 16% of all cases representing 4% of the fractures without dislocation and 80% of the fracture dislocations. Fracture dislocation (p=0.02) and AVN (p=0.005) had a negative effect on the Constant Score, with AVN being a predictor for a high level of pain (p=0.04). Secondary dislocation of the greater tuberosity was seen in two patients, loosening of screws in one patient and a fracture below the plate in another one. Secondary dislocation or loss of reduction of the head was not recorded. Angle stable plate fixation with tension band wiring of the tuberosities is an effective and safe option to treat this difficult fractures, also in elderly patients with osteoporotic bone. Because 40% of the 4-part fractures with fracture dislocation yielded a satisfactory or better result, the plate fixator with angular stability may be an alternative to prosthetic replacement in selected cases.

Entities:  

Mesh:

Year:  2004        PMID: 15292960     DOI: 10.1007/s00113-004-0818-7

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  53 in total

1.  Plate fixation of proximal humeral fractures with indirect reduction: surgical technique and results utilizing three shoulder scores.

Authors:  M Hessmann; F Baumgaertel; H Gehling; I Klingelhoeffer; L Gotzen
Journal:  Injury       Date:  1999-09       Impact factor: 2.586

Review 2.  Assessment and management of three-and four-part proximal humeral fractures.

Authors:  J Rees; J Hicks; W Ribbans
Journal:  Clin Orthop Relat Res       Date:  1998-08       Impact factor: 4.176

Review 3.  [Proximal and distal humerus fractures in advanced age].

Authors:  H Lill; C Josten
Journal:  Orthopade       Date:  2000-04       Impact factor: 1.087

4.  Outcome after hemiarthroplasty for three- and four-part fractures of the proximal humerus.

Authors:  K Zyto; W A Wallace; S P Frostick; B J Preston
Journal:  J Shoulder Elbow Surg       Date:  1998 Mar-Apr       Impact factor: 3.019

5.  Rigid internal fixation of fractures of the proximal humerus in older patients.

Authors:  B Hintermann; H H Trouillier; D Schäfer
Journal:  J Bone Joint Surg Br       Date:  2000-11

6.  Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus.

Authors:  A J Wijgman; W Roolker; T W Patt; E L F B Raaymakers; R K Marti
Journal:  J Bone Joint Surg Am       Date:  2002-11       Impact factor: 5.284

Review 7.  Percutaneous fixation of proximal humeral fractures.

Authors:  D Herscovici; D T Saunders; M P Johnson; R Sanders; T DiPasquale
Journal:  Clin Orthop Relat Res       Date:  2000-06       Impact factor: 4.176

8.  Biomechanical effects of malposition of tuberosity fragments on the humeral prosthetic reconstruction for four-part proximal humerus fractures.

Authors:  M A Frankle; D P Greenwald; B A Markee; L E Ondrovic; W E Lee
Journal:  J Shoulder Elbow Surg       Date:  2001 Jul-Aug       Impact factor: 3.019

9.  [Angle- and rotation-stable internal fixation of proximal humerus fractures with the humerus fixator plate. Early clinical experience with a newly developed implant].

Authors:  H Mückter; L Herzog; M Becker; W Vogel; P J Meeder; J Buchholz
Journal:  Chirurg       Date:  2001-11       Impact factor: 0.955

10.  [Minimal osteosynthesis of fractures of the head of the humerus. Indications, technic, results].

Authors:  G Siebler; H Walz; E H Kuner
Journal:  Unfallchirurg       Date:  1989-04       Impact factor: 1.000

View more
  24 in total

1.  Surgical treatment of Neer Group VI proximal humeral fractures: retrospective comparison of PHILOS® and hemiarthroplasty.

Authors:  Christian Spross; Andreas Platz; Matthias Erschbamer; Thomas Lattmann; Michael Dietrich
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

2.  [Results after treatment of instable fractures of the proximal humerus using a fixed-angle plate].

Authors:  C Hessler; U Schmucker; G Matthes; A Ekkernkamp; R Gütschow; C Eggers
Journal:  Unfallchirurg       Date:  2006-10       Impact factor: 1.000

Review 3.  Meta-analysis comparing locking plate fixation with hemiarthroplasty for complex proximal humeral fractures.

Authors:  Jiezhi Dai; Yimin Chai; Chunyang Wang; Gen Wen
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-07

4.  The calcar screw in angular stable plate fixation of proximal humeral fractures--a case study.

Authors:  Georg Osterhoff; Christian Ossendorf; Guido A Wanner; Hans-Peter Simmen; Clément M Werner
Journal:  J Orthop Surg Res       Date:  2011-09-24       Impact factor: 2.359

5.  [Operative treatment of proximal humeral fractures with helix wire].

Authors:  F Müller; R Voithenleitner; C Schuster; P Angele; B Weigel
Journal:  Unfallchirurg       Date:  2006-12       Impact factor: 1.000

6.  Da Vinci System: clinical experience with complex proximal humerus fractures.

Authors:  Raffaele Russo; Valeria Visconti; Luigi Vernaglia Lombardi; Michele Ciccarelli; Fabio Cautiero
Journal:  Musculoskelet Surg       Date:  2010-05

7.  [Osteosynthesis of displaced fractures of the greater tuberosity with the Bamberg plate].

Authors:  D Popp; V Schöffl; W Strecker
Journal:  Oper Orthop Traumatol       Date:  2016-08-02       Impact factor: 1.154

8.  Additive fiber-cerclages in proximal humeral fractures stabilized by locking plates: no effect on fracture stabilization and rotator cuff function in human shoulder specimens.

Authors:  Christine Voigt; Christof Hurschler; Louise Rechi; Rolf Vosshenrich; Helmut Lill
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

9.  [Effect of additive fiber cerclage of the rotator cuff in angle-stable plate-stabilized proximal humeral fractures: a biomechanical study of human shoulder specimens].

Authors:  C Voigt; C Hurschler; J Althainz; R Vosshenrich; H Lill
Journal:  Unfallchirurg       Date:  2008-07       Impact factor: 1.000

10.  Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus? A prospective series of 87 patients.

Authors:  Peter Helwig; Christian Bahrs; Björn Epple; Justus Oehm; Christoph Eingartner; Kuno Weise
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.