Literature DB >> 16944077

[Results after treatment of instable fractures of the proximal humerus using a fixed-angle plate].

C Hessler1, U Schmucker, G Matthes, A Ekkernkamp, R Gütschow, C Eggers.   

Abstract

BACKGROUND: Fixed-angle implants are being increasingly used in surgery of fractures of the proximal humerus. The aim of this retrospective investigation was to evaluate the outcome after fracture reduction utilizing a fixed-angle plate (Königsee).
MATERIALS AND METHODS: Between January 2003 and April 2004, 58 patients were operated, 52 of whom received a fixed-angle implant; 46 cases were harvested for a follow-up examination. Each patient was re examined clinically and radiologically at least 6 and 18 months after surgery. The functional outcome was evaluated using the Constant Score and the Simple Shoulder Test. The results were compared to results of other investigations.
RESULTS: The mean patient age was 68.8 years (34-94 years). Fractures were classified using the Neer Classification: 12 were classified as two-part, 25 as three-part, and 9 as four-part fractures. Three of the three-part and four of the four-part fractures were rated as luxation fractures. The overall functional outcome of all cases was good. More than 18 months after surgery the mean general "Constant Score" was 57; the mean side-related "Constant Score" was 89%. The Simple Shoulder Test revealed a pain-free range of motion in 41 (89.1%) of the individuals. The majority of the patients were satisfied with the results regarding remaining range of activity of the injured limb. In five cases significant complications occurred. In two cases the head of the humerus collapsed, and in one case a necrosis of the head occurred. In one individual the implant broke after an additional trauma. In this case a re-osteosynthesis utilizing a tibia plate was performed and the patient was excluded from further follow-up investigations. One soft tissue infection occurred after initial surgery.
CONCLUSION: It has been shown that results after fixation of proximal humerus fractures with fixed-angle implants are good. The functional outcome is good and complications are rare. Our results correlate with other investigations regarding fracture reduction using fixed-angle plates and nails.

Entities:  

Mesh:

Year:  2006        PMID: 16944077     DOI: 10.1007/s00113-006-1138-x

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  18 in total

1.  [Indication and technique for shoulder endoprostheses in fractures].

Authors:  A Rüter
Journal:  Chirurg       Date:  2001-11       Impact factor: 0.955

2.  [Primary management of comminuted humeral head fracture in the elderly patient with a humerus head prosthesis].

Authors:  A Boss; B Hintermann
Journal:  Unfallchirurg       Date:  1997-11       Impact factor: 1.000

3.  A clinical method of functional assessment of the shoulder.

Authors:  C R Constant; A H Murley
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

4.  The reproducibility of classification of fractures of the proximal end of the humerus.

Authors:  K A Siebenrock; C Gerber
Journal:  J Bone Joint Surg Am       Date:  1993-12       Impact factor: 5.284

Review 5.  Percutaneous fixation of proximal humeral fractures.

Authors:  D Herscovici; D T Saunders; M P Johnson; R Sanders; T DiPasquale
Journal:  Clin Orthop Relat Res       Date:  2000-06       Impact factor: 4.176

6.  [T-plate osteosynthesis in dislocated proximal humerus fractures].

Authors:  H Lill; K Lange; J Prasse-Badde; A Schmidt; P Verheyden; V Echtermeyer
Journal:  Unfallchirurgie       Date:  1997-10

7.  [The cannulated blade plate 90 degrees for displaced proximal humeral fractures in elderly patients].

Authors:  M Fuchs; A Losch; K M Stürmer
Journal:  Zentralbl Chir       Date:  2003-01       Impact factor: 0.942

8.  The epidemiology of proximal humeral fractures.

Authors:  C M Court-Brown; A Garg; M M McQueen
Journal:  Acta Orthop Scand       Date:  2001-08

9.  Outcome after primary and secondary hemiarthroplasty in elderly patients with fractures of the proximal humerus.

Authors:  U Bosch; M Skutek; R W Fremerey; H Tscherne
Journal:  J Shoulder Elbow Surg       Date:  1998 Sep-Oct       Impact factor: 3.019

10.  [Treatment of dislocated 3- and 4-part fractures of the proximal humerus with an angle-stabilizing fixation plate].

Authors:  R Hente; J Kampshoff; B Kinner; B Füchtmeier; M Nerlich
Journal:  Unfallchirurg       Date:  2004-09       Impact factor: 1.000

View more
  6 in total

1.  Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures.

Authors:  Ralph Zettl; Thorben Müller; Tobias Topp; Ulrike Lewan; Antonio Krüger; Christian Kühne; Steffen Ruchholtz
Journal:  Int Orthop       Date:  2011-02-08       Impact factor: 3.075

2.  [Arthroscopic implant removal after fixed-angle plate osteosynthesis of the proximal humerus. Technique and initial results in comparison to open implant removal].

Authors:  J C Katthagen; G Jensen; D Hennecke; H Lill; C Voigt
Journal:  Unfallchirurg       Date:  2012-01       Impact factor: 1.000

3.  Proximal humeral fractures: an understanding of the ideal plate positioning.

Authors:  Pedro José Labronici; Rodrigo Pires e Albuquerque; Vinícius Schott; Robinson Esteves Santos Pires; Willian Dias Belangero; José Sérgio Franco
Journal:  Int Orthop       Date:  2014-07-20       Impact factor: 3.075

4.  [Complex fracture of the proximal humerus in the elderly. Locking plate osteosynthesis vs hemiarthroplasty].

Authors:  M Dietrich; C Meier; T Lattmann; U Zingg; P Grüninger; A Platz
Journal:  Chirurg       Date:  2008-03       Impact factor: 0.955

5.  Is locking nailing of humeral head fractures superior to locking plate fixation?

Authors:  G Gradl; A Dietze; M Kääb; W Hopfenmüller; T Mittlmeier
Journal:  Clin Orthop Relat Res       Date:  2009-06-13       Impact factor: 4.176

Review 6.  Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus.

Authors:  Stig Brorson; Lars H Frich; Annika Winther; Asbjørn Hróbjartsson
Journal:  Acta Orthop       Date:  2011-06-10       Impact factor: 3.717

  6 in total