Literature DB >> 15288979

Impact of cataract on the results of frequency-doubling technology perimetry.

Angelo P Tanna1, Charlie Abraham, Jerry Lai, Joy Shen.   

Abstract

PURPOSE: To determine the effect of cataract on the results of frequency-doubling technology (FDT) perimetry.
DESIGN: Consecutive cohort study. PARTICIPANTS: Forty-four patients with normal ophthalmic examinations, with the exception of cataract, scheduled to undergo phacoemulsification and posterior chamber lens implantation were prospectively identified and completed the study.
METHODS: All subjects underwent FDT perimetry using the full-threshold C-20 strategy. Both eyes were tested within 1 month before cataract surgery and up to 3 months after surgery. The unoperated fellow eyes served as controls. MAIN OUTCOME MEASURES: Changes in visual acuity (VA), mean deviation (MD), and pattern standard deviation (PSD) were evaluated. For each subject, the change in MD and PSD in the eye that underwent cataract surgery was adjusted for change in the control eye that is thought to occur due to a learning effect.
RESULTS: Among the eyes that underwent cataract surgery, the median preoperative VA was 20/60 (range, 20/30-20/800) and the mean preoperative MD was -4.00+/-3.72 decibels (dB). Postoperatively, the median VA improved to 20/30 (range, 20/20-20/70) and the mean postoperative MD was -0.26+/-3.09 dB (P<0.001). Among the control eyes, MDs were -1.74+/-3.71 dB preoperatively and -0.94+/-3.85 dB postoperatively (P = 0.019). The adjusted improvement in MD among eyes that underwent cataract surgery was 2.94+/-3.44 dB (P<0.001). There was no significant change in PSD. Preoperative VA correlated significantly with preoperative MD (r = 0.39, P = 0.01). The improvement in VA correlated significantly with the adjusted improvement in MD (r = 0.38, P = 0.01).
CONCLUSIONS: Cataract has an adverse effect on the MD but not the PSD in FDT perimetry. Among eyes with visually significant cataract, the MD correlates significantly with VA. After cataract surgery, the change in VA correlates significantly with the adjusted change in MD.

Entities:  

Mesh:

Year:  2004        PMID: 15288979     DOI: 10.1016/j.ophtha.2004.01.035

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  9 in total

1.  How should we manage an amblyopic patient with cataract?

Authors:  J E Hale; S Murjaneh; N A Frost; R A Harrad
Journal:  Br J Ophthalmol       Date:  2006-02       Impact factor: 4.638

Review 2.  [Functional glaucoma diagnosis].

Authors:  C Erb; K Göbel
Journal:  Ophthalmologe       Date:  2009-04       Impact factor: 1.059

Review 3.  Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma.

Authors:  M A R Siddiqui; A Azuara-Blanco; S Neville
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

4.  The effect of yellow tinted intraocular lenses on the result of frequency doubling perimetry after cataract surgery.

Authors:  Jae-Yun Kim; Jin-A Choi; Kyung-Sun Na; Choun-Ki Joo
Journal:  Korean J Ophthalmol       Date:  2011-01-17

5.  Measuring visual function in age-related macular degeneration with frequency-doubling (matrix) perimetry.

Authors:  Andrew John Anderson; Chris A Johnson; John S Werner
Journal:  Optom Vis Sci       Date:  2011-07       Impact factor: 1.973

6.  Effects of different levels of intraocular stray light on kinetic perimetry findings.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Karen Isono; Manami Tsuchiya
Journal:  PLoS One       Date:  2015-05-12       Impact factor: 3.240

7.  Changes in frequency-doubling perimetry in patients with type I diabetes prior to retinopathy.

Authors:  Isabel Pinilla; Antonio Ferreras; Miriam Idoipe; Ana I Sanchez-Cano; Diana Perez-Garcia; Laura X Herrera; Maria J Pinilla; Emilio Abecia
Journal:  Biomed Res Int       Date:  2013-11-11       Impact factor: 3.411

8.  The Effect of Cataract on Early Stage Glaucoma Detection Using Spatial and Temporal Contrast Sensitivity Tests.

Authors:  Johann Klein; Barbara K Pierscionek; Jan Lauritzen; Karin Derntl; Andrzej Grzybowski; Margarita B Zlatkova
Journal:  PLoS One       Date:  2015-06-08       Impact factor: 3.240

9.  Alzheimer's disease: screening biomarkers using frequency doubling technology visual field.

Authors:  Denise A Valenti
Journal:  ISRN Neurol       Date:  2013-09-25
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.