Literature DB >> 21478785

Measuring visual function in age-related macular degeneration with frequency-doubling (matrix) perimetry.

Andrew John Anderson1, Chris A Johnson, John S Werner.   

Abstract

PURPOSE: To determine the agreement between the Humphrey Matrix perimeter 10-2 test and the 10-2 Humphrey Field Analyzer (HFA) test when assessing visual function in patients with age-related macular degeneration (AMD).
METHODS: Forty-two eyes of 42 subjects with AMD (average 75.0 years, SD=6.2: median visual acuity in logarithm of the minimum angle of resolution of 0.26, range, -0.12 to 1.04) were evaluated with the Matrix and HFA 10-2 visual field tests. Mean deviation (MD), pattern standard deviation, and test time were recorded. We calculated spatial concordance of individual test locations, being the proportion of spatially agreeing locations with identical classification (normal vs. abnormal, p < 5%) on the pattern deviation plot. As multiple HFA stimuli overlapped with some Matrix locations, several criteria for grouping HFA data into locations were investigated.
RESULTS: Both MD and pattern standard deviation were significantly correlated for the two devices (r(2)=0.79 and r(2)=0.80, respectively, p<0.0001). Using our standard criterion for abnormal HFA locations (≥50% stimuli abnormal), the median spatial concordance was 0.76, with 95% of tests giving a concordance of ≥0.59. A small, but significant, increase in concordance occurred when a stricter criterion (all stimuli abnormal at a location) was applied. Median fixation loss percentages were 7 and 0% for the HFA and Matrix, respectively. Visual acuity in logarithm of the minimum angle of resolution showed modest correlations with both defect depth (HFA MD: r(2)=0.39, p<0.0001) and size of defect (number of abnormal points on the HFA: r(2)=0.24, p<0.0001).
CONCLUSIONS: Using a simple metric to calculate spatial concordance, the Matrix 10-2 test quantifies the spatial extent of significant depression of the central visual fields in AMD in a manner similar to the HFA 10-2. The spatial extent and depth of central visual field loss in AMD are only modestly predicted by visual acuity measurements.
Copyright © 2011 American Academy of Optometry

Entities:  

Mesh:

Year:  2011        PMID: 21478785      PMCID: PMC3132570          DOI: 10.1097/OPX.0b013e31821861bd

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  42 in total

1.  Temporal sensitivity deficits in patients with high-risk drusen.

Authors:  J A Phipps; R H Guymer; A J Vingrys
Journal:  Aust N Z J Ophthalmol       Date:  1999 Jun-Aug

2.  Phenomenology of eccentric fixation.

Authors:  G K VON NOORDEN; G MACKENSEN
Journal:  Am J Ophthalmol       Date:  1962-04       Impact factor: 5.258

3.  Characteristics of the normative database for the Humphrey matrix perimeter.

Authors:  Andrew John Anderson; Chris A Johnson; Murray Fingeret; John L Keltner; Paul G D Spry; Michael Wall; John S Werner
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-04       Impact factor: 4.799

4.  Effect of cataract surgery with intraocular lens implant on frequency doubling perimetry.

Authors:  Hemamalini Arvind; Ronnie George; M Baskaran; Prema Raju; S Ve Ramesh; Pradeep G Paul; Lingam Vijaya
Journal:  Curr Eye Res       Date:  2005-02       Impact factor: 2.424

5.  Flicker sensitivity and fundus appearance in pre-exudative age-related maculopathy.

Authors:  M J Mayer; B Ward; R Klein; J B Talcott; R F Dougherty; A Glucs
Journal:  Invest Ophthalmol Vis Sci       Date:  1994-03       Impact factor: 4.799

6.  Frequency doubling technology perimetry using a 24--2 stimulus presentation pattern.

Authors:  C A Johnson; G A Cioffi; E M Van Buskirk
Journal:  Optom Vis Sci       Date:  1999-08       Impact factor: 1.973

7.  Localized scotomata detected with temporal modulation perimetry in central serous chorioretinopathy.

Authors:  A J Vingrys; K Pesudovs
Journal:  Aust N Z J Ophthalmol       Date:  1999-04

8.  Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma.

Authors:  Paul H Artes; Donna M Hutchison; Marcelo T Nicolela; Raymond P LeBlanc; Balwantray C Chauhan
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-07       Impact factor: 4.799

9.  Visual field deficits in early age-related macular degeneration.

Authors:  M J Tolentino; S Miller; A R Gaudio; M A Sandberg
Journal:  Vision Res       Date:  1994-02       Impact factor: 1.886

10.  Effect of intermittent versus continuous patient monitoring on reliability indices during automated perimetry.

Authors:  L N Johnson; A Aminlari; J W Sassani
Journal:  Ophthalmology       Date:  1993-01       Impact factor: 12.079

View more
  7 in total

1.  The visualFields package: a tool for analysis and visualization of visual fields.

Authors:  Iván Marín-Franch; William H Swanson
Journal:  J Vis       Date:  2013-03-14       Impact factor: 2.240

2.  Quantification of visual field loss in age-related macular degeneration.

Authors:  Jennifer H Acton; Jonathan M Gibson; Robert P Cubbidge
Journal:  PLoS One       Date:  2012-06-29       Impact factor: 3.240

3.  Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes.

Authors:  Rongrong Hu; Chenkun Wang; Lyne Racette
Journal:  PLoS One       Date:  2017-05-18       Impact factor: 3.240

4.  Correlation of Central Versus Peripheral Macular Structure-Function With Acuity in Age-Related Macular Degeneration.

Authors:  Faran Sabeti; Jo Lane; Emilie M F Rohan; Bhim B Rai; Rohan W Essex; Elinor McKone; Ted Maddess
Journal:  Transl Vis Sci Technol       Date:  2021-02-05       Impact factor: 3.283

5.  An Objective Perimetry Study of Central Versus Peripheral Sensitivities and Delays in Age-Related Macular Degeneration.

Authors:  Bhim B Rai; Rohan W Essex; Faran Sabeti; Ted Maddess; Emilie M F Rohan; Joshua P van Kleef; Corinne F Carle
Journal:  Transl Vis Sci Technol       Date:  2021-12-01       Impact factor: 3.283

Review 6.  Should clinical automated perimetry be considered for routine functional assessment of early/intermediate age-related macular degeneration (AMD)? A systematic review of current literature.

Authors:  Matt Trinh; Michael Kalloniatis; Lisa Nivison-Smith
Journal:  Ophthalmic Physiol Opt       Date:  2021-11-29       Impact factor: 3.992

7.  Evaluating the Performance of qVFM in Mapping the Visual Field of Simulated Observers With Eye Diseases.

Authors:  Pengjing Xu; Luis Andres Lesmes; Deyue Yu; Zhong-Lin Lu
Journal:  Front Neurosci       Date:  2021-06-21       Impact factor: 4.677

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.