Literature DB >> 21350691

The effect of yellow tinted intraocular lenses on the result of frequency doubling perimetry after cataract surgery.

Jae-Yun Kim1, Jin-A Choi, Kyung-Sun Na, Choun-Ki Joo.   

Abstract

PURPOSE: To investigate the effect of yellow tinted intraocular lenses (IOLs), implanted in the bag after phacoemulsification, on the result of frequency doubling technique (FDT) perimetry.
METHODS: For 68 eyes of 52 patients, an IOL was implanted in the bag after phacoemulsification. The patients were categorized into three groups according to the type of implanted IOLs used. IOLs were selected randomly among two types of yellow IOLs (Acrysof SN60WF IOL, Hoya YA60BBR IOL) and a clear IOL was used as a control. A FDT Humphrey matrix was performed 2 months after the surgery. The mean deviation (MD) and pattern standard deviation (PSD) among these three groups was analyzed using Mann-Whitney U-test.
RESULTS: TWO MONTHS AFTER THE PROCEDURE, THERE WAS NO SIGNIFICANT DIFFERENCE BETWEEN EACH OF THE THREE GROUPS: the clear IOL and Hoya YA60BBR IOL (MD, p = 0.21; PSD, p = 0.27), the clear IOL and Alcon SN60WF IOL (MD, p = 0.11; PSD, p = 0.22), and the Hoya YA60BBR IOL and Alcon SN60WF IOL (MD, p = 0.33; PSD, p = 0.56).
CONCLUSIONS: When interpreting the result of the FDT after cataract surgery, the color and type of IOLs used should not be considered.

Entities:  

Keywords:  Frequency doubling perimetry; Yellow tinted intraocular lenses

Mesh:

Year:  2011        PMID: 21350691      PMCID: PMC3039191          DOI: 10.3341/kjo.2011.25.1.29

Source DB:  PubMed          Journal:  Korean J Ophthalmol        ISSN: 1011-8942


  12 in total

1.  Rod-cone interactions assessed in inferred magnocellular and parvocellular postreceptoral pathways.

Authors:  H Sun; J Pokorny; V C Smith
Journal:  J Vis       Date:  2001       Impact factor: 2.240

2.  Light-transmission-spectrum comparison of foldable intraocular lenses.

Authors:  Paul H Ernest
Journal:  J Cataract Refract Surg       Date:  2004-08       Impact factor: 3.351

Review 3.  Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma.

Authors:  Paolo Fogagnolo; Luca Rossetti; Stefano Ranno; Antonio Ferreras; Nicola Orzalesi
Journal:  Prog Brain Res       Date:  2008       Impact factor: 2.453

4.  Rod inputs to macaque ganglion cells.

Authors:  B B Lee; V C Smith; J Pokorny; J Kremers
Journal:  Vision Res       Date:  1997-10       Impact factor: 1.886

5.  Architecture of rod and cone circuits to the on-beta ganglion cell.

Authors:  P Sterling; M A Freed; R G Smith
Journal:  J Neurosci       Date:  1988-02       Impact factor: 6.167

6.  Effects of yellow intraocular lenses on light-induced upregulation of vascular endothelial growth factor.

Authors:  Yasuo Yanagi; Yuji Inoue; Aya Iriyama; Woo-Dong Jang
Journal:  J Cataract Refract Surg       Date:  2006-09       Impact factor: 3.351

7.  Frequency doubling technology perimetry after clear and yellow intraocular lens implantation.

Authors:  Tetsuo Ueda; Takeo Ota; Eiichi Yukawa; Yoshiaki Hara
Journal:  Am J Ophthalmol       Date:  2006-11       Impact factor: 5.258

8.  Mechanisms of chromatic rod vision in scotopic illumination.

Authors:  U Stabell; B Stabell
Journal:  Vision Res       Date:  1994-04       Impact factor: 1.886

9.  Effect of cataract extraction on frequency doubling technology perimetry.

Authors:  Michael S Kook; Sung Jae Yang; Suhyun Kim; Jiyong Chung; Soon-Tae Kim; Hungwon Tchah
Journal:  Am J Ophthalmol       Date:  2004-07       Impact factor: 5.258

10.  Impact of cataract on the results of frequency-doubling technology perimetry.

Authors:  Angelo P Tanna; Charlie Abraham; Jerry Lai; Joy Shen
Journal:  Ophthalmology       Date:  2004-08       Impact factor: 12.079

View more
  3 in total

Review 1.  Ultraviolet or blue-filtering intraocular lenses: what is the evidence?

Authors:  S M Downes
Journal:  Eye (Lond)       Date:  2016-01-08       Impact factor: 3.775

2.  Effect of intraocular lens implantation on visual field in glaucoma and comorbid cataracts.

Authors:  Can Zhao; Qing Cun; Yi-Jin Tao; Wen-Yan Yang; Hua Zhong; Feng-Jie Li; Sean Tighe; Ying-Ting Zhu; Ting Wang
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

Review 3.  Blue-light filtering intraocular lenses (IOLs) for protecting macular health.

Authors:  Laura E Downie; Ljoudmila Busija; Peter R Keller
Journal:  Cochrane Database Syst Rev       Date:  2018-05-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.