Literature DB >> 15284990

Polyethylene post failure in posterior stabilized total knee arthroplasty.

Henry D Clarke1, Kevin R Math, Giles R Scuderi.   

Abstract

Posterior-stabilized (PS) prostheses have been used extensively in total knee arthroplasty (TKA), with excellent long-term results. The key feature of these prostheses is the femoral cam and tibial post mechanism that limits posterior displacement and produces femoral rollback. Although articular-surface polyethylene wear of the tibial component has not been a significant clinical problem, tibial post wear has been reported. In distinction to chronic post wear, little information exists about catastrophic post failure. We present the case of a 56-year-old woman who presented 63 months after TKA with a PS prosthesis with acute fracture of the polyethylene post. The evaluation and treatment of this patient, including the previously unreported use of computed tomography arthrography to diagnose this rare problem, is reviewed.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15284990     DOI: 10.1016/j.arth.2004.02.026

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  17 in total

1.  Implant design influences tibial post wear damage in posterior-stabilized knees.

Authors:  Mark M Dolan; Natalie H Kelly; Joseph T Nguyen; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

2.  Tibial post wear in posterior-stabilized knee replacements is design-dependent.

Authors:  Bridgette D Furman; Joseph Lipman; Mordechai Kligman; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2008-08-14       Impact factor: 4.176

Review 3.  Causes of failure and etiology of painful primary total knee arthroplasty.

Authors:  Romain Seil; Dietrich Pape
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-08-11       Impact factor: 4.342

4.  Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.

Authors:  Shinichi Kuriyama; Katsufumi Hyakuna; Satoshi Inoue; Yasutsugu Kawai; Yasuyuki Tamaki; Hiromu Ito; Shuichi Matsuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-02-14       Impact factor: 4.342

5.  Fracture of a polyethylene tibial post in a Scorpio posterior-stabilized knee prosthesis.

Authors:  Hong Chul Lim; Ji Hoon Bae; Jin Ho Hwang; Seung Joo Kim; Ji Yeol Yoon
Journal:  Clin Orthop Surg       Date:  2009-05-27

6.  Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs.

Authors:  N Arnout; L Vanlommel; J Vanlommel; J P Luyckx; L Labey; B Innocenti; J Victor; J Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-22       Impact factor: 4.342

7.  Comparison of stability and kinematics of the natural knee versus a PS TKA with a 'third condyle'.

Authors:  Stefano Zaffagnini; Simone Bignozzi; Mo Saffarini; Francesca Colle; Bharat Sharma; Plamen Slavov Kinov; Maurilio Marcacci; David Dejour
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-06       Impact factor: 4.342

8.  Two stage fracture of a polyethylene post in a 9-year-old posterior-stabilized knee prosthesis: a case report.

Authors:  Fabio D'Angelo; Daniele Marcolli; Paolo Bulgheroni; Luigi Murena; Terenzio Congiu; Paolo Cherubino
Journal:  J Med Case Rep       Date:  2010-02-23

Review 9.  How to treat a tibial post fracture in total knee arthroplasty? A systematic review.

Authors:  Paul F Lachiewicz
Journal:  Clin Orthop Relat Res       Date:  2010-10-21       Impact factor: 4.176

Review 10.  Anterior knee pain following primary total knee arthroplasty.

Authors:  David Shervin; Katelyn Pratt; Travis Healey; Samantha Nguyen; William M Mihalko; Mouhanad M El-Othmani; Khaled J Saleh
Journal:  World J Orthop       Date:  2015-11-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.