Literature DB >> 15248573

Weighted FBP--a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch.

Karl Stierstorfer1, Annabella Rauscher, Jan Boese, Herbert Bruder, Stefan Schaller, Thomas Flohr.   

Abstract

A new 3D reconstruction scheme, weighted filtered backprojection (WFBP) for multirow spiral CT based on an extension of the two-dimensional SMPR algorithm is described and results are presented. In contrast to other 3D algorithms available, the algorithm makes use of all available data for all pitch values. The algorithm is a FBP algorithm: linear convolution of the parallel data along the row direction followed by a 3D backprojection. Data usage for arbitrary pitch values is maintained through a weighting scheme which takes into account redundant data. If proper row weighting is applied, the image quality is superior to the image quality of the SMPR algorithm.

Entities:  

Mesh:

Year:  2004        PMID: 15248573     DOI: 10.1088/0031-9155/49/11/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  34 in total

1.  Filtered Backprojection Reconstruction with Depth-Dependent Filtering.

Authors:  Frank Dennerlein; Holger Kunze; Frédéric Noo
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

2.  Axial Cone-Beam Reconstruction by Weighted BPF/DBPF and Orthogonal Butterfly Filtering.

Authors:  Shaojie Tang; Xiangyang Tang
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-03       Impact factor: 4.538

3.  Validation of a Projection-domain Insertion of Liver Lesions into CT Images.

Authors:  Baiyu Chen; Chi Ma; Shuai Leng; Jeff L Fidler; Shannon P Sheedy; Cynthia H McCollough; Joel G Fletcher; Lifeng Yu
Journal:  Acad Radiol       Date:  2016-07-16       Impact factor: 3.173

4.  Image reconstruction and image quality evaluation for a dual source CT scanner.

Authors:  T G Flohr; H Bruder; K Stierstorfer; M Petersilka; B Schmidt; C H McCollough
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Low-dose CT perfusion with projection view sharing.

Authors:  Thomas Martin; John Hoffman; Jeff R Alger; Michael McNitt-Gray; Danny Jj Wang
Journal:  Med Phys       Date:  2017-11-17       Impact factor: 4.071

6.  DukeSim: A Realistic, Rapid, and Scanner-Specific Simulation Framework in Computed Tomography.

Authors:  Ehsan Abadi; Brian Harrawood; Shobhit Sharma; Anuj Kapadia; William P Segars; Ehsan Samei
Journal:  IEEE Trans Med Imaging       Date:  2018-12-12       Impact factor: 10.048

7.  Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner.

Authors:  Zhicong Yu; Shuai Leng; Steffen Kappler; Katharina Hahn; Zhoubo Li; Ahmed F Halaweish; Andre Henning; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-14

8.  Estimation of signal and noise for a whole-body research photon-counting CT system.

Authors:  Zhoubo Li; Shuai Leng; Zhicong Yu; Steffen Kappler; Cynthia H McCollough
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-22

9.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.

Authors:  Shuai Leng; Wei Zhou; Zhicong Yu; Ahmed Halaweish; Bernhard Krauss; Bernhard Schmidt; Lifeng Yu; Steffen Kappler; Cynthia McCollough
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

10.  Clinical evaluation of the normalized metal artefact reduction algorithm caused by dental fillings in CT.

Authors:  X-Y Gong; E Meyer; X-J Yu; J-H Sun; L-P Sheng; K-H Huang; R-Z Wu
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.