Literature DB >> 15234286

Effect of cataract extraction on frequency doubling technology perimetry.

Michael S Kook1, Sung Jae Yang, Suhyun Kim, Jiyong Chung, Soon-Tae Kim, Hungwon Tchah.   

Abstract

PURPOSE: To investigate the effect of cataract extraction on the results of frequency doubling technology (FDT) perimetry in healthy subjects.
DESIGN: Single-center, prospective, case series.
METHODS: We performed FDT threshold C20-1 and Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast programs within 1 month before and 2 months after phacoemulsification in 52 consecutive nonglaucomatous patients. Global indexes, including mean deviation and mean sensitivity of FDT and mean deviation of SITA-fast, were compared before and after cataract surgery. Mean sensitivity of FDT at various visual field grid locations was also compared before and after cataract surgery, as were localized indexes of both FDT and SITA-fast.
RESULTS: Mean deviation improved after cataract surgery in both FDT threshold (from -7.09 dB--2.16 dB) and SITA-fast program (from -6.14 dB--2.87 dB). The mean sensitivity at 17 grid locations when the FDT threshold program was used significantly improved postoperatively (from 19.6 dB-26.13 dB). Postoperative improvements in mean sensitivity were also significant at all different sectors, but there were no significant differences of improvement among them. Postoperative pattern standard deviations from FDT and SITA-fast did not differ significantly from their preoperative values.
CONCLUSIONS: Cataracts induced a generalized reduction of sensitivity in FDT threshold as well as SITA-fast perimetry. Cataract removal did not change pattern standard deviation of FDT or of SITA-fast. Caution should be taken when interpreting the results of FDT perimetry in the eyes with cataract.

Entities:  

Mesh:

Year:  2004        PMID: 15234286     DOI: 10.1016/j.ajo.2004.03.020

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  7 in total

Review 1.  [Functional glaucoma diagnosis].

Authors:  C Erb; K Göbel
Journal:  Ophthalmologe       Date:  2009-04       Impact factor: 1.059

Review 2.  Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma.

Authors:  M A R Siddiqui; A Azuara-Blanco; S Neville
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

3.  The effect of yellow tinted intraocular lenses on the result of frequency doubling perimetry after cataract surgery.

Authors:  Jae-Yun Kim; Jin-A Choi; Kyung-Sun Na; Choun-Ki Joo
Journal:  Korean J Ophthalmol       Date:  2011-01-17

4.  Measuring visual function in age-related macular degeneration with frequency-doubling (matrix) perimetry.

Authors:  Andrew John Anderson; Chris A Johnson; John S Werner
Journal:  Optom Vis Sci       Date:  2011-07       Impact factor: 1.973

5.  The Effect of Cataract on Eye Movement Perimetry.

Authors:  G Thepass; J J M Pel; K A Vermeer; O Creten; S R Bryan; H G Lemij; J van der Steen
Journal:  J Ophthalmol       Date:  2015-05-20       Impact factor: 1.909

6.  Effects of different levels of intraocular stray light on kinetic perimetry findings.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Karen Isono; Manami Tsuchiya
Journal:  PLoS One       Date:  2015-05-12       Impact factor: 3.240

7.  The Effect of Cataract on Early Stage Glaucoma Detection Using Spatial and Temporal Contrast Sensitivity Tests.

Authors:  Johann Klein; Barbara K Pierscionek; Jan Lauritzen; Karin Derntl; Andrzej Grzybowski; Margarita B Zlatkova
Journal:  PLoS One       Date:  2015-06-08       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.