Literature DB >> 1523311

The pelvis: T2-weighted fast spin-echo MR imaging.

H V Nghiem1, R J Herfkens, I R Francis, F G Sommer, R B Jeffrey, K C Li, R M Steiner, G H Glover.   

Abstract

Fast spin-echo (SE) T2-weighted magnetic resonance (MR) imaging provides images with highly T2-weighted contrast in substantially reduced imaging times. In a prospective evaluation, fast SE T2-weighted imaging of the pelvis was compared with conventional SE T2-weighted imaging in 30 consecutive patients in whom pelvic pathologic conditions were suspected. Three reviewers independently analyzed the images for (a) overall image quality, (b) pelvic organ definition, (c) conspicuity of pelvic fluid, and (d) conspicuity of pelvic pathologic conditions. Fast SE images were rated superior to conventional SE T2-weighted images in 60% (54 of 90) of the case reviews for overall image quality, in 69% (62 of 90) for pelvic organ definition, in 63% (57 of 90) for conspicuity of pelvic fluid, and in 68% (43 of 63) for conspicuity of pelvic pathologic conditions. The fast SE examinations were typically three to four times faster than conventional SE T2-weighted examinations. No pathologic findings seen on conventional SE T2-weighted images were undetected on fast SE images. Fast SE images may replace conventional SE T2-weighted images in MR imaging of the pelvis.

Entities:  

Mesh:

Year:  1992        PMID: 1523311     DOI: 10.1148/radiology.185.1.1523311

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  MR imaging of focal liver lesions: comparison between turbo spin-echo and conventional spin-echo pulse sequences.

Authors:  A Giovagnoni; E Paci; P Ercolani; B Kiefer; P Santino; A Piga
Journal:  MAGMA       Date:  1995 Sep-Dec       Impact factor: 2.310

Review 2.  CT and MRI of ovarian cancer.

Authors:  R Forstner; H Hricak; S White
Journal:  Abdom Imaging       Date:  1995 Jan-Feb

3.  Liver MR imaging: comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery.

Authors:  M T Keogan; C E Spritzer; E K Paulson; S S Paine; L Harris; J L Dahlke; J R MacFall
Journal:  Abdom Imaging       Date:  1996 Sep-Oct

4.  Sensitivity of T2-weighted FSE sequences towards physiological iron depositions in normal brains at 1.5 and 3.0 T.

Authors:  T Allkemper; W Schwindt; D Maintz; W Heindel; B Tombach
Journal:  Eur Radiol       Date:  2004-03-19       Impact factor: 5.315

  4 in total