Literature DB >> 25540578

Optic disc topography in Malay patients with normal-tension glaucoma and primary open-angle glaucoma.

Abdul Rahim Adlina1, Koh Alisa-Victoria2, Ismail Shatriah2, Ahmad Tajudin Liza-Sharmini2, Mt Saad Ahmad3.   

Abstract

BACKGROUND: There are limited data concerning the optic disc topography in normal-tension glaucoma (NTG) and primary open-angle glaucoma (POAG) patients living in Southeast Asian countries. This study aims to compare optic disc parameters in patients with NTG and POAG in Malaysia and to discuss the results in comparison with studies of NTG and POAG in other Asian countries.
METHODS: This prospective cross-sectional study was performed in two hospitals with glaucoma service in Malaysia from 2010 to 2012. Seventy-seven patients of Malay ethnicity were enrolled in this study, including 32 NTG patients and 45 POAG patients. Using the Heidelberg Retinal Tomograph III, we measured optic disc area, cup area, rim area, cup volume, rim volume, cup-to-disc area ratio, mean cup depth, maximum cup depth, cup shape measure, height variation contour, mean retinal nerve fiber layer thickness, and retinal nerve fiber layer cross-sectional area.
RESULTS: The eyes for NTG patients had significantly larger optic disc areas (2.65 [standard deviation, 0.41] vs 2.40 [standard deviation, 0.36] mm(2), respectively; P=0.006) and cup areas (1.54 [standard deviation, 0.43] vs 1.32 [standard deviation, 0.40] mm(2), respectively; P=0.027) compared with the eyes of POAG patients. Comparison of the other parameters between the two groups revealed no significant difference (P>0.050). The moderate and severe NTG patients showed significantly deeper cups and larger disc and cup areas when compared with the moderate and severe POAG patients (P<0.050).
CONCLUSION: The NTG patients in this study have notably larger optic disc and cup areas than the POAG patients. Our observations are consistent with those reported in studies of NTG and POAG patients in Korea. The deeper cups and larger disc and cup areas may serve as indicators of severity when comparing NTG with POAG. However, these findings require verification with IOP and visual field results.

Entities:  

Keywords:  Heidelberg Retina Topography III; Malay ethnicity; normal-tension glaucoma; optic disc topography; primary open-angle glaucoma

Year:  2014        PMID: 25540578      PMCID: PMC4270355          DOI: 10.2147/OPTH.S71136

Source DB:  PubMed          Journal:  Clin Ophthalmol        ISSN: 1177-5467


Introduction

Normal-tension glaucoma (NTG) is more common than primary open-angle glaucoma (POAG) in Northeast Asian countries. The prevalence rate of NTG in Japan and Korea ranges from 2.0% to 3.6%, whereas the rate of POAG ranges from 0.2% to 0.8%.1–5 However, the scenario is different in the Southeastern Asian region. The prevalence of NTG was reported to be lower than that of POAG in Malaysia, Thailand, and the Phillipines.6–9 The Malay ethnicity represents the third largest ethnic group in Asia and remains the main ethnic group in Malaysia, Indonesia, and Brunei. Previous descriptions of the appearance of the optic disc in glaucomatous patients have been restricted to studies of Malay people living in Singapore.10–13 There are limited data available on glaucoma patients of Malay ethnicity outside of Singapore. The Heidelberg Retinal Tomograph (HRT) III (Heidelberg Engineering, Heidelberg, Germany) has been widely used to describe the characteristics of the optic disc in glaucoma patients in recent years.14–20 Our study aims to investigate the differences in optic disc parameters between NTG and POAG patients of Malay ethnicity in Malaysia, using HRT III analysis.

Methods

This was a prospective comparative cross-sectional study involving patients with NTG and POAG at two Glaucoma Service Units in Malaysia from November 2010 to February 2012. We recruited 77 Malay patients, including 32 NTG and 45 POAG patients. Approval was obtained from the Ethical Committee of the Ministry of Health, Malaysia, and the Research and Ethical Committee at the School of Medical Sciences, Universiti Sains Malaysia. The study protocol was conducted in accordance with the Declaration of Helsinki on human research. Written informed consent was obtained from all patients in the study. The study details were described previously.21 NTG patients were recruited on the basis of clinical criteria defined by the Collaborative Normal Tension Glaucoma Study,22 which included the presence of glaucomatous cupping with a corresponding visual field defect and a median intraocular pressure (IOP) of less than 21 mmHg, but never exceeding 24 mmHg, in at least 10 readings conducted in either eye. Patients with POAG were defined as having glaucomatous optic neuropathy in the presence of an open angle and no other ocular abnormality to account for a secondary mechanism.23 POAG patients with an IOP of more than 21 mmHg were considered in this study. The subjects recruited in both studied groups were of Malay ethnicity extending back at least two generations, including all parents and grandparents. For both groups, we excluded patients’ congenital and secondary glaucoma, gonioscopic findings of a closed angle, the presence of peripheral anterior synechiae, pseudoexfoliation membrane, angle recession and new vessel formations at the angle, dense media opacity, myopia greater than −6.0 diopter, and a tilted optic disc. Patients with diabetic retinopathy, retinitis pigmentosa, nonglaucomatous optic neuropathy, or central nervous system diseases were also excluded. All patients underwent a thorough ocular assessment, including evaluation of the visual acuity, refraction, IOP measurements, and anterior segment, as well as funduscopy, gonioscopy, and fundus photograph documentation. IOP phasing was performed in the NTG group. The vertical cup disc ratio was determined on the basis of clinical examination and the evaluation of fundus photographs by an identified glaucoma specialist at both centers. Both groups of patients were further subcategorized as having clinical moderate glaucoma when the vertical cup disc ratio ranged from 0.7 to 0.8, or clinically advanced glaucoma when the vertical cup disc ratio ranged from 0.9 to fully cupped. All patients underwent visual field assessment with 24-2 program. An age- and power-adjusted spherical correction was added to the distance refraction to achieve best corrected vision. The loss of visual field was considered significant when three or more congruous nonedge points were present in the typical arcuate area, a depressed pattern deviation plot at a P<5% level with at least one point depressed at a P<1% level was observed, the corrected pattern standard deviation was significant at the P<5% level, and the Glaucoma Hemifield Test was outside the normal limits. A minimum of two reliable visual field tests was required. The visual field assessments were considered reliable only when the false-positive rate was 15% or lower, the false-negative rate was 30% or lower, and the fixation loss was less than 15%. The Advanced Glaucoma Intervention Study (AGIS) score was calculated on the basis of the results of the visual field assessment with the 24-2 program (Swedish Interactive Threshold Algorithm standard). All patients were then subcategorized as having mild (1–5 points), moderate (6–11 points), or end-stage impairment of the visual field (12–20 points), according to the score.24 All patients underwent the HRT III. The analysis of optic disc topography was performed by an identified investigator at each center. High-quality images were ensured according to the criteria described by Bowd et al.25 The data were obtained from the right eye if both eyes were eligible, or from the worse eye in asymmetrical cases. The data analyses were performed using Predictive Analysis Software statistics version 18.0 (IBM Corporation, Armonk, NY, USA). Demographic and ophthalmic data were compared using an independent t-test for continuous variables that were normally distributed. Comparisons between the groups were performed with the Mann–Whitney rank sum test for continuous variables that were not normally distributed. A P-value of <0.05 was considered statistically significant.

Results

A total of 77 patients were included in the study (NTG n=32, POAG n=45). The mean ages of the NTG and POAG groups were 64.0 years (standard deviation, 9.3 years) and 64.9 years (standard deviation, 9.2 years), respectively. There was a slightly higher number of women in the POAG group (55.6%) compared with in the NTG group (50.0%). The severity of glaucoma in both groups was further objectively subcategorized on the basis of the clinical assessment and the AGIS score. These data are summarized in Table 1.
Table 1

Demographic and clinical characteristics

CharacteristicNTG (n=32)POAG (n=45)P-value
Age, years0.905*
 Mean ± SD64.0±9.364.9±9.2
 Minimum45.045.0
 Maximum84.082.0
Sex, n (%)0.630
 Female16 (50.00%)25 (55.60%)
 Male16 (50.00%)20 (44.40%)
Selected eye, n (%)0.685
 RE17 (53.10%)26 (57.80%)
 LE15 (46.90%)19 (42.20%)
Spherical equivalent, D0.431*
 Mean ± SD+0.28±1.63−0.11±1.33
MD, dB0.773*
 Mean ± SD−10.35±8.76−11.27±8.46
CPSD, dB0.195*
 Mean ± SD5.03±3.426.86±3.87
VCDR, n (%)0.307
 Clinical moderate18 (56.25%)20 (44.44%)
 Clinical advanced14 (43.75%)25 (55.56%)
AGIS score, n (%)0.222
 Mild10 (31.26%)7 (15.55%)
 Moderate11 (34.37%)16 (35.55%)
 Severe–end stage11 (34.37%)22 (48.90%)

Notes:

Independent t-test applied.

Pearson chi-square test applied. Level of significance was set at 0.05.

Abbreviations: NTG, normal-tension glaucoma; POAG, primary open-angle glaucoma; SD, standard deviation; RE, right eye; LE, left eye; D, diopter; MD, mean deviation; CPSD, corrected pattern standard deviation; VCDR, vertical cup-to-disc ratio; AGIS, Advanced Glaucoma Intervention Study.

Table 2 presents the comparison of the mean optic disc parameters between the NTG and POAG groups. Patients with NTG had significantly larger disc and cup areas than those with POAG (P=0.006 and P=0.027, respectively). The other HRT III parameters such as rim area, cup volume, rim volume, vertical cup/disc ratio, mean cup depth, and mean retinal nerve fiber layer thickness were not significantly different between patients with NTG and those with POAG (P>0.05).
Table 2

Comparison of the mean values of the optic disc parameters between NTG and POAG patients

Optic disc parametersMean ± SD
MD (95% CI)T stat (df)P-value*
NTG (n=32)POAG (n=45)
Disc area, mm22.65±0.412.40±0.360.26 (0.08–0.44)2.84 (75)0.006
Cup area, mm21.54±0.431.32±0.400.22 (0.02–0.40)2.25 (75)0.027
Rim area, mm21.12±0.411.07±0.440.05 (−0.15–0.24)0.45 (75)0.651
Cup volume, mm30.47±0.280.40±0.37−1.320.187
Rim volume, mm30.23±0.130.21±0.150.02 (−0.05–0.08)0.50 (75)0.617
Cup/disc area ratio0.58±0.140.55±0.150.03 (−0.04–0.09)0.72 (75)0.473
Linear cup/disc ratio0.76±0.090.74±0.110.02 (−0.03–0.07)0.80 (75)0.425
Mean cup depth, mm0.37±0.090.35±0.130.12 (−0.03–0.07)0.74 (75)0.461
Maximum cup depth, mm0.77±0.160.75±0.230.02 (−0.07–0.12)0.44 (75)0.663
Cup shape measure−0.04±0.06−0.06±0.060.02 (−0.01–0.05)−1.25 (75)0.123
Height variation contour, mm0.39±0.190.33±0.15−1.630.103
Mean RNFL thickness, mm0.15±0.100.15±0.080.00 (−0.04–0.04)0.83 (75)0.934
RNFL cross-sectional area, mm20.88±0.600.83±0.480.05 (−0.19–0.30)0.43 (75)0.670

Notes:

Independent t-test was applied.

Median (interquartile range).

Z stat.

Mann–Whitney test was applied. Bold text indicates that the values reached significant level.

Abbreviations: NTG, normal-tension glaucoma; POAG, primary open-angle glaucoma; SD, standard deviation; MD, mean difference; CI, confidence interval; df, degree of freedom; RNFL, retina nerve fiber layer.

Tables 3 and 4 describe the comparison of the NTG and POAG on the basis of the clinical assessment. The moderately severe NTG patients were noted to present significantly deeper cups compared with their POAG counterparts (P=0.02). Meanwhile, advanced NTG patients had significantly larger cup areas when compared with advanced POAG patients (P=0.039). The other optic nerve head parameters were comparable between the two groups (P>0.05).
Table 3

Comparisons of the optic disc parameters between moderate NTG and POAG patients (based on clinical assessment)

Optic disc parametersMean ± SD
MD (95% CI)T stat (df)P-value*
Moderate NTG (n=18)Moderate POAG (n=20)
Disc area, mm22.71±0.402.49±0.380.22 (−0.40–0.48)1.72 (36)0.095
Cup area, mm21.38±0.331.17±0.370.21 (−0.02–0.44)1.82 (36)0.076
Rim area, mm21.33±0.311.32±0.440.01 (−0.25–0.26)0.07 (36)0.945
Cup volume, mm30.43±0.180.31±0.200.12 (0.00–0.25)1.98 (36)0.055
Rim volume, mm30.30±0.110.28±0.180.02 (−0.08–0.12)0.40 (36)0.694
Cup/disc area ratio0.51±0.100.47±0.140.04 (−0.04–0.12)0.94 (36)0.354
Linear cup/disc ratio0.71±0.070.68±0.110.03 (−0.03–0.09)1.08 (36)0.288
Mean cup depth, mm0.37±0.070.30±0.100.07 (0.01–0.13)2.44 (36)0.020
Maximum cup depth, mm0.78±0.240.61±0.252.280.023
Cup shape measure−0.05±0.05−0.08±0.050.03 (−0.01–0.06)1.61 (36)0.117
Height variation contour, mm0.38±0.090.36±0.090.02 (−0.04–0.08)0.67 (36)0.492
Mean RNFL thickness, mm0.21±0.060.19±0.070.03 (−0.02–0.07)1.29 (36)0.207
RNFL cross-sectional area, mm21.24±0.351.04±0.430.20 (−0.06–0.46)1.53 (36)0.135

Notes:

Independent t-test was applied.

Median (interquartile range).

Z stat.

Mann–Whitney test was applied. Bold text indicates that the values reached significant level.

Abbreviations: NTG, normal-tension glaucoma; POAG, primary open-angle glaucoma; SD, standard deviation; MD, mean difference; CI, confidence interval; df, degree of freedom; RNFL, retina nerve fiber layer.

Table 4

Comparisons of the optic disc parameters between advanced NTG and POAG (based on clinical assessment)

Optic disc parametersMean ± SD
MD (95% CI)T stat (df)P-value*
Advanced NTG (n=14)Advanced POAG (n=25)
Disc area, mm22.58±0.422.31±0.370.26 (0.00–0.53)2.02 (37)0.050
Cup area, mm21.74±0.461.44±0.380.29 (0.02–0.57)2.14 (37)0.039
Rim area, mm20.84±0.360.87±0.33−0.03 (−0.26–0.20)−0.26 (37)0.795
Cup volume, mm30.62±0.350.53±0.240.09 (−0.11–0.28)0.92 (37)0.365
Rim volume, mm30.11±0.090.13±0.13−0.950.340
Cup/disc area ratio0.67±0.130.62±0.130.05 (−0.04–0.14)1.13 (37)0.264
Linear cup/disc ratio0.82±0.080.78±0.080.03 (−0.03–0.09)1.10 (37)0.277
Mean cup depth, mm0.36±0.110.39±0.13−0.02 (−0.11–0.06)−0.54 (37)0.593
Maximum cup depth, mm0.76±0.200.82±0.23−0.06 (−0.21–0.09)−0.86 (37)0.393
Cup shape measure−0.02±0.07−0.06±0.06−1.390.163
Height variation contour, mm0.39±0.240.30±0.14−1.200.229
Mean RNFL thickness, mm0.10±0.130.13±0.10−1.640.101
RNFL cross-sectional area, mm20.54±0.760.70±0.49−1.380.169

Notes:

Independent t-test was applied.

Median (interquartile range).

Z stat.

Mann–Whitney test was applied. Bold text indicates that the values reached significant level.

Abbreviations: NTG, normal-tension glaucoma; POAG, primary open-angle glaucoma; SD, standard deviation; MD, mean difference; CI, confidence interval; df, degree of freedom; RNFL, retina nerve fiber layer.

The disc area was significantly larger in moderately severe and advanced NTG patients when compared with the POAG patients, based on the AGIS score (P=0.032 and P=0.026, respectively). These findings are summarized in Tables 5 and 6. We did not detect any significant difference in this parameter between the group with mild NTG and the group with mild POAG (P>0.05). No significant differences were detected in the other optic nerve head parameters between the two groups, based on severity according to AGIS score (P>0.05).
Table 5

Comparisons of the optic disc parameters between moderate NTG and POAG patients (based on AGIS score)

Optic disc parametersMedian (interquantile range)
Z statP-value*
Moderate NTG (n=11)Moderate POAG (n=16)
Disc area, mm22.65 (0.72)2.25 (0.44)−2.140.032
Cup area, mm21.61 (0.62)1.22 (0.45)−1.990.047
Rim area, mm21.03 (0.35)0.85 (0.50)−0.250.804
Cup volume, mm30.47 (0.26)0.33 (0.23)−0.960.340
Rim volume, mm30.35 (0.23)0.22 (0.13)−0.860.389
Cup/disc area ratio0.51 (0.17)0.53 (0.16)−1.070.284
Linear cup/disc ratio0.72 (0.11)0.73 (0.11)−1.010.311
Mean cup depth, mm0.35 (0.12)0.30 (0.10)−0.080.939
Maximum cup depth, mm0.77 (0.27)0.62 (0.17)−0.080.939
Cup shape measure−0.04 (0.10)−0.08 (0.05)−0.610.540
Height variation contour, mm0.37 (0.10)0.34 (0.07)−1.190.236
Mean RNFL thickness, mm0.19 (0.14)0.16 (0.09)−1.610.108
RNFL cross-sectional area, mm21.23 (0.79)0.84 (0.50)−1.400.163

Notes:

Mann–Whitney test was applied. Bold text indicates that the values reached significant level.

Abbreviations: NTG, normal-tension glaucoma; POAG, primary open-angle glaucoma; RNFL, retina nerve fiber layer; AGIS, Advanced Glaucoma Intervention Study.

Table 6

Comparisons of the optic disc parameters between advanced-stage NTG and POAG (based on AGIS score)

Optic disc parametersMedian (interquantile range)
Z statP-value*
Severe NTG (n=11)Severe POAG (n=22)
Disc area, mm22.47 (0.60)2.28 (0.41)−2.220.026
Cup area, mm21.66 (0.61)1.40 (0.57)−1.580.114
Rim area, mm20.81 (0.34)0.85 (0.50)−1.430.152
Cup volume, mm30.63 (0.44)0.55 (0.45)−1.800.071
Rim volume, mm30.12 (0.09)0.13 (0.13)−1.140.256
Cup/disc area ratio0.67 (0.15)0.63 (0.20)−0.070.941
Linear cup/disc ratio0.82 (0.09)0.80 (0.13)−0.070.941
Mean cup depth, mm0.36 (0.13)0.39 (0.24)−1.780.075
Maximum cup depth, mm0.77 (0.24)0.83 (0.40)−1.310.191
Cup shape measure−0.02 (0.07)−0.05 (0.10)−1.340.180
Height variation contour, mm0.38 (0.24)0.32 (0.15)−0.890.373
Mean RNFL thickness, mm0.09 (0.14)0.13 (0.10)−1.290.198
RNFL cross-sectional area, mm20.52 (0.77)0.70 (0.53)−1.680.093

Notes:

Mann–Whitney test was applied. Bold text indicates that the values reached significant level.

Abbreviations: NTG, normal-tension glaucoma; POAG, primary open-angle glaucoma; RNFL, retina nerve fiber layer; AGIS, Advanced Glaucoma Intervention Study.

Discussion

Table 7 describes the published articles reporting comparisons of optic disc topography between NTG and POAG patients from Asia; the majority of these studies were carried out in Korea and Japan.26–29 We were unable to find any other comparison studies on similar topics in other Asian populations. Confocal scanning laser tomography and HRT analysis were used in the previously published studies.26–29 HRT III was implemented in our study. Because of the different modalities used in these studies, we intend to compare the observed trends, but we are unable to directly compare the measurement of all parameters between studies.
Table 7

Comparison of the optic disc parameters between NTG and POAG patients in published articles

Mean parameters ± SDCurrent study, 2014 (Malaysia)Yang and Park, 1997 (Korea)26Shin et al 2008 (Korea)27Nakatsue et al 2004 (Japan)29Kiriyama et al 2003 (Japan)28
GroupNTGPOAGNTGPOAGNTGPOAGNTGPOAGNTGPOAG
Number of subjects, n324520234010060602317
Mean age ± SD64.0±9.3464.9±9.2455.1±10.651.5±11.754.3±9.952.8±10.554.8±13.853.2±13.059.7±10.257.4±9.7
Disc area (mm2)2.65±0.412.40±0.362.70±0.512.22±0.592.78±0.482.41±0.582.40±0.702.25±0.422.33±0.482.23±0.53
Cup area (mm2)1.54±0.431.32±0.401.51±0.461.11±0.601.34±0.591.26±0.501.46±0.581.10±0.55
Rim area (mm2)1.12± 0.411.07±0.441.15±0.271.10±0.381.27±0.281.27±0.331.06±0.380.99±0.320.82±0.211.14±0.35
Cup volume (mm3)0.47±0.280.40±0.370.53±0.330.37±0.380.47±0.220.37±0.300.37±0.250.41±0.320.51±0.350.29±0.21
Rim volume (mm3)0.23±0.130.21±0.150.27±0.090.30±0.150.23±0.120.21±0.120.18±0.100.30±0.13
Cup/disc area ratio0.58±0.140.55±0.150.56±0.120.47±0.220.53±0.100.45±0.170.54±0.150.55±0.170.63±0.120.47±0.17
Mean cup depth (mm)0.37±0.090.35±0.130.37±0.130.30±0.130.36±0.100.33±0.120.38±0.130.33±0.14
Maximum cup depth (mm)0.77±0.160.75±0.230.76±0.190.69±0.210.77±0.200.73±0.190.81±0.220.73±0.25
Cup shape measure−0.04±0.06−0.06±0.06−0.04±0.09−0.11±0.13−0.06±0.08−0.09±0.09−0.06±0.08−0.07±0.10−0.06±0.05−0.09±0.06
Height variation contour (mm)0.39±0.190.33±0.150.34±0.110.36± 0.110.41±0.140.39±0.110.42±0.160.50±0.18
Mean RNFL thickness (mm)0.15±0.100.15±0.080.19±0.070.20±0.730.16±0.080.25±0.11
RNFL cross sectional area (mm2)0.88±0.600.83±0.481.12±0.401.09±0.360.83±0.411.31±0.62

Abbreviations: NTG, normal tension glaucoma; POAG, primary open angle glaucoma; SD, standard deviation; RNFL, retinal nerve fiber layer.

We observed that the mean disc area in NTG patients was significantly larger compared with in the POAG group. Our observation is consistent with the results of Korean studies.26,27 Yang and Park noted that the mean disc area was 2.70±0.51 mm2 in NTG patients and 2.22±0.59 mm2 in POAG patients (P=0.002).26 Shin et al reported that the mean disc area was 2.78±0.48 mm2 in NTG patients and 2.41±0.58 mm2 in POAG patients (P=0.001).27 In contrast, no significant differences in the mean disc area were detected in NTG and POAG patients from Japan and Italy.28–30 Our NTG patients had a significantly larger cup area compared with the POAG patients. This result is in agreement with reports by Shin et al and Kiriyama et al.27,28 Shin et al reported that the mean cup area was 1.51±0.46 mm2 in their NTG patients and 1.11±0.60 mm2 in POAG patients (P=0.001).27 Kiriyama et al reported a mean cup area of 1.46±0.58 mm2 in the Japanese patients with NTG and 1.10±0.55 mm2 with POAG (P=0.031).28 However, Nakatsue et al and Lester and Mikelberg reported that there were no significant differences between these two groups.29,30 Yang and Park did not mention in their analysis.26 A larger optic disc size in NTG patients compared with in patients with other types of glaucoma has also been reported in non-Asian population.31,32 We noted that the cup was significantly deeper in the NTG patients compared with the POAG patients, with moderate severity on clinical assessment. However, the disc and cup areas were persistently larger in the groups with advanced disease according to the clinical assessment and AGIS scoring. Thus, we suggest that the cup depth and the disc and cup areas may serve as indicators to differentiate the severity of NTG and POAG. However, this evaluation should also be accompanied by measurements of the IOP and visual field in clinical practice. The cup-to-disc ratio and other optic nerve head parameters were comparable between the NTG and POAG patients in this study. This observation is in agreement with Shin et al.27 Interestingly, Kiriyama et al noted that their NTG patients displayed a significantly smaller mean rim area, thinner mean retinal nerve fiber layer, smaller retinal nerve fiber layer cross-sectional area, larger mean cup volume, and increased mean cup/disc area ratio when compared with POAG patients.28 All optic nerve head parameters were similar between the NTG and POAG groups in the two subsequent studies.29,30 In conclusion, our findings support the existing data on optic disc parameters in NTG and POAG patients from other Asian countries. Our NTG patients had deeper cups and larger optic disc and cup areas in comparison with the POAG patients. These parameters may serve as important optic disc characteristics to differentiate moderate NTG or POAG from the advanced stages of these diseases. However, measurement of IOP and visual field analysis are still the main indicators in clinical practice.
  30 in total

1.  Refractive error, axial dimensions, and primary open-angle glaucoma: the Singapore Malay Eye Study.

Authors:  Shamira A Perera; Tien Y Wong; Wan-Ting Tay; Paul J Foster; Seang-Mei Saw; Tin Aung
Journal:  Arch Ophthalmol       Date:  2010-07

2.  Comparison of optic nerve head parameters using Heidelberg Retina Tomograph 3 and spectral-domain optical coherence tomography.

Authors:  Shino Sato; Kazuyuki Hirooka; Tetsuya Baba; Fumio Shiraga
Journal:  Clin Exp Ophthalmol       Date:  2012-05-17       Impact factor: 4.207

3.  Glaucoma detection with the Heidelberg retina tomograph 3.

Authors:  Zvia Burgansky-Eliash; Gadi Wollstein; Richard A Bilonick; Hiroshi Ishikawa; Larry Kagemann; Joel S Schuman
Journal:  Ophthalmology       Date:  2006-11-30       Impact factor: 12.079

4.  Diagnostic ability of Heidelberg Retina Tomography in detecting glaucoma in a population setting: the Singapore Malay Eye Study.

Authors:  Yingfeng Zheng; Tien Y Wong; Ecosse Lamoureux; Paul Mitchell; Seng-Chee Loon; Seang Mei Saw; Tin Aung
Journal:  Ophthalmology       Date:  2009-12-14       Impact factor: 12.079

5.  Comparison of glaucomatous progression between untreated patients with normal-tension glaucoma and patients with therapeutically reduced intraocular pressures. Collaborative Normal-Tension Glaucoma Study Group.

Authors: 
Journal:  Am J Ophthalmol       Date:  1998-10       Impact factor: 5.258

6.  Heidelberg Retina Tomograph 3 machine learning classifiers for glaucoma detection.

Authors:  K A Townsend; G Wollstein; D Danks; K R Sung; H Ishikawa; L Kagemann; M L Gabriele; J S Schuman
Journal:  Br J Ophthalmol       Date:  2008-06       Impact factor: 4.638

7.  Are large optic nerve heads susceptible to glaucomatous damage at normal intraocular pressure? A three-dimensional study by laser scanning tomography.

Authors:  R O Burk; K Rohrschneider; H Noack; H E Völcker
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

8.  Diabetes, metabolic abnormalities, and glaucoma.

Authors:  Gavin S Tan; Tien Y Wong; Chee-Weng Fong; Tin Aung
Journal:  Arch Ophthalmol       Date:  2009-10

9.  Optic disc topography of normal tension glaucoma patients in Malaysia.

Authors:  Abdul Rahim Adlina; Ismail Shatriah; Ahmad Tajudin Liza Sharmini; Mt Saad Ahmad
Journal:  Med J Malaysia       Date:  2013-08

10.  Prevalence and characteristics of glaucoma among Korean adults.

Authors:  Ji Hyun Kim; Sung Yong Kang; Na Rae Kim; Eun Suk Lee; Samin Hong; Gong Je Seong; Young Jae Hong; Chan Yun Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11
View more
  4 in total

Review 1.  Asian Race and Primary Open-Angle Glaucoma: Where Do We Stand?

Authors:  Aditya Belamkar; Alon Harris; Francesco Oddone; Alice Verticchio Vercellin; Anna Fabczak-Kubicka; Brent Siesky
Journal:  J Clin Med       Date:  2022-04-28       Impact factor: 4.964

Review 2.  Normal tension glaucoma: review of current understanding and mechanisms of the pathogenesis.

Authors:  H E Killer; A Pircher
Journal:  Eye (Lond)       Date:  2018-02-19       Impact factor: 3.775

3.  Structure-function relationship between Bruch's membrane opening-minimum rim width and perimetry in open-angle glaucoma subtypes.

Authors:  Ruoshi Li; Xia Wang; Yahui Wei; Yuan Fang; Tian Tian; Mei Li; Yu Cai; Yingzi Pan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-12-10       Impact factor: 3.117

4.  Latest Developments in Normal-Pressure Glaucoma: Diagnosis, Epidemiology, Genetics, Etiology, Causes and Mechanisms to Management.

Authors:  Jacky W Y Lee; Poemen P Chan; XiuJuan Zhang; Li Jia Chen; Jost B Jonas
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019 Nov-Dec
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.