Literature DB >> 15214542

Performance evaluation of the 16-module quad-HIDAC small animal PET camera.

John Missimer1, Zoltan Madi, Michael Honer, Claudia Keller, August Schubiger, Simon-Mensah Ametamey.   

Abstract

The quad-HIDAC small animal PET camera is a quadratic array of high-density avalanche chambers; the camera described in this publication consists of 16 modules. We present the system response using point and line sources and a mouse phantom. The quad-HIDAC camera exhibits a count rate stability of better than 1% and linearity of response to coincidences up to 2.2 x 10(5) cps at 16 MBq activity. Corrected for deadtime and random coincidences, the efficiency for the line source is 0.011, of which unscattered coincidences yield 0.009. The scatter fraction originating from the detectors is 0.22. Absorption within the mouse phantom was 20% and the scatter fraction increased to 0.29. Resolution is uniform within the entire field-of-view, which is 28 cm axially and 17 cm radially. Reconstruction of a point source yields a resolution of 1.1 mm FWHM for all three components. The performance of the camera demonstrates its excellent suitability for the functional imaging of small animals.

Entities:  

Mesh:

Year:  2004        PMID: 15214542     DOI: 10.1088/0031-9155/49/10/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

Review 1.  Small animal PET: aspects of performance assessment.

Authors:  Simone Weber; Andreas Bauer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-10-02       Impact factor: 9.236

Review 2.  Novel detector technology for clinical PET.

Authors:  Roger Lecomte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

3.  NanoPET imaging of [(18)F]fluoromisonidazole uptake in experimental mouse tumours.

Authors:  Matthias T Wyss; Michael Honer; Pius A Schubiger; Simon M Ametamey
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-10-29       Impact factor: 9.236

4.  Longitudinal and multimodal in vivo imaging of tumor hypoxia and its downstream molecular events.

Authors:  Steffi Lehmann; Daniel P Stiehl; Michael Honer; Marco Dominietto; Ruth Keist; Ivana Kotevic; Kristin Wollenick; Simon Ametamey; Roland H Wenger; Markus Rudin
Journal:  Proc Natl Acad Sci U S A       Date:  2009-07-31       Impact factor: 11.205

5.  Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.

Authors:  Y Gu; J L Matteson; R T Skelton; A C Deal; E A Stephan; F Duttweiler; T M Gasaway; C S Levin
Journal:  Phys Med Biol       Date:  2011-02-18       Impact factor: 3.609

6.  Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.

Authors:  F Habte; A M K Foudray; P D Olcott; C S Levin
Journal:  Phys Med Biol       Date:  2007-05-29       Impact factor: 3.609

7.  Wavelet denoising in voxel-based parametric estimation of small animal PET images: a systematic evaluation of spatial constraints and noise reduction algorithms.

Authors:  Yi Su; Kooresh I Shoghi
Journal:  Phys Med Biol       Date:  2008-10-03       Impact factor: 3.609

8.  Are [O-methyl-11C]derivatives of ICI 89,406 beta1-adrenoceptor selective radioligands suitable for PET?

Authors:  Marilyn P Law; Stefan Wagner; Klaus Kopka; Victor W Pike; Otmar Schober; Michael Schäfers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-09-29       Impact factor: 9.236

9.  A prototype PET scanner with DOI-encoding detectors.

Authors:  Yongfeng Yang; Yibao Wu; Jinyi Qi; Sara St James; Huini Du; Purushottam A Dokhale; Kanai S Shah; Richard Farrell; Simon R Cherry
Journal:  J Nucl Med       Date:  2008-06-13       Impact factor: 10.057

10.  Comparison of [18F]-tracers in various experimental tumor models by PET imaging and identification of an early response biomarker for the novel microtubule stabilizer patupilone.

Authors:  T Ebenhan; M Honer; S M Ametamey; P A Schubiger; M Becquet; S Ferretti; C Cannet; M Rausch; P M J McSheehy
Journal:  Mol Imaging Biol       Date:  2009-05-22       Impact factor: 3.488

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.