Literature DB >> 15194092

Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis.

T Ashraf1, J H Newman, V V Desai, D Beard, J E Nevelos.   

Abstract

Polyethylene wear is considered a threat to the long-term survival of unicompartmental knee replacement (UKR). This study aims to determine the linear penetration and volumetric wear associated with a non-congruent commonly used UKR, the St Georg Sled. This prosthesis has a biconvex femoral component which articulates with a flat polyethylene tibial component resulting in point contact. Components were retrieved from the knees of 19 patients undergoing revision for a failed UKR after primary replacement. Linear penetration and volumetric wear was measured using a coordinate measuring machine. Using an un-used implant, a three-dimensional computer model of the surface was generated and compared to the explanted specimen. Most patients had revisions because of disease progression to other compartments rather than specific wear related pathology. The mean linear wear for the sample was 0.89 mm (S.D. 0.59 mm) over an average period of 5.6 years giving the mean linear penetration rate of 0.15 mm/year. The mean volumetric wear was 99.7 mm3 (S.D. 79.3 mm3) over the same period giving a mean annual volumetric wear rate of 17.3 mm3/year. The results in this study indicate that clinically significant wear is not necessarily a feature of this fixed bearing unicompartmental knee replacement. The pattern of wear is consistent with clinical findings and indicates excavation of the polyethylene after implantation but at a slower rate than would be anticipated.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15194092     DOI: 10.1016/j.knee.2004.03.004

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  15 in total

1.  Early failure of a mobile-bearing unicompartmental knee replacement.

Authors:  Mateen H Arastu; J Vijayaraghavan; H Chissell; J B Hull; J H Newman; J R Robinson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-31       Impact factor: 4.342

2.  Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners.

Authors:  Christopher B Knowlton; Priyanka Bhutani; Markus A Wimmer
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-07-12       Impact factor: 3.368

3.  How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study.

Authors:  Robin Pourzal; Christopher B Knowlton; Deborah J Hall; Michel P Laurent; Robert M Urban; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2016-02-18       Impact factor: 4.176

4.  Does bearing design influence midterm survivorship of unicompartmental arthroplasty?

Authors:  John-Paul Whittaker; Douglas D R Naudie; James P McAuley; Richard W McCalden; Steven J MacDonald; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-07-14       Impact factor: 4.176

5.  A novel radiographic technique to assess 180° rotational spin of the Oxford unicompartmental knee mobile bearing.

Authors:  Salman Jamshed; Rohi Shah; Arrish Arooj; Adrian Turner; Christos Plakogiannis
Journal:  J Orthop       Date:  2020-08-26

Review 6.  [Implant with a mobile or a fixed bearing in unicompartmental knee joint replacemen].

Authors:  G Matziolis; S Tohtz; B Gengenbach; C Perka
Journal:  Orthopade       Date:  2007-12       Impact factor: 1.087

Review 7.  Fixed- versus mobile-bearing unicondylar knee arthroplasty: are failure modes different?

Authors:  Tao Cheng; Daoyun Chen; Chen Zhu; Xiaoyun Pan; Xin Mao; Yongyuan Guo; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-09-25       Impact factor: 4.342

8.  An autonomous mathematical reconstruction to effectively measure volume loss on retrieved polyethylene tibial inserts.

Authors:  Christopher B Knowlton; Markus A Wimmer
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-08-22       Impact factor: 3.368

9.  The effect of C-arm fluoroscope on unicompartmental knee replacement arthroplasty.

Authors:  Hee-Gon Park; Kun-Woong Yu; Sung-Hyun Kim; Dong-Ho Lee
Journal:  J Orthop       Date:  2018-08-10

Review 10.  Outcome of Unicompartmental Knee Arthroplasty: A Systematic Review of Comparative Studies between Fixed and Mobile Bearings Focusing on Complications.

Authors:  Young-Bong Ko; Manan Ramesh Gujarathi; Kwang-Jun Oh
Journal:  Knee Surg Relat Res       Date:  2015-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.