Literature DB >> 15191144

Image denoising based on multiscale singularity detection for cone beam CT breast imaging.

Junmei Zhong1, Ruola Ning, David Conover.   

Abstract

It was recently reported that the real-time flat panel detector-based cone-beam computed tomography (CBCT) breast imaging can help improve the detectability of small breast tumors with an X-ray dose comparable to that of the conventional mammography. In this paper, an efficient denoising algorithm is proposed to further reduce the X-ray exposure level required by a CBCT scan to acquire acceptable image quality. The proposed wavelet-based denoising algorithm possesses three significant characteristics: 1) wavelet coefficients at each scale are classified into two categories: irregular coefficients, and edge-related and regular coefficients; 2) noise in irregular coefficients is reduced as much as possible without producing artifacts to the denoised images; and 3) for the edge-related and regular coefficients, if they are at the first decomposition level, they are further denoised, otherwise, no modifications are made to them so as to obtain good visual quality for diagnosis. By applying the proposed denoising algorithm to the filtered projection images, the X-ray exposure level necessary for the CBCT scan can be reduced by up to 60% while obtaining clinically acceptable image quality. This denoising result indicates that in the clinical application of CBCT breast imaging, the patient radiation dose can be significantly reduced.

Entities:  

Mesh:

Year:  2004        PMID: 15191144     DOI: 10.1109/tmi.2004.826944

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  11 in total

1.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

2.  Multiscale penalized weighted least-squares sinogram restoration for low-dose X-ray computed tomography.

Authors:  Jing Wang; Zhengrong Liang; Hongbing Lu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

3.  X-ray scatter correction method for dedicated breast computed tomography.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

4.  Cone beam CT: a current overview of devices.

Authors:  A Nemtoi; C Czink; D Haba; A Gahleitner
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

5.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.

Authors:  Xiaoxuan Zhang; Ali Uneri; J Webster Stayman; Corinna C Zygourakis; Sheng-Fu L Lo; Nicholas Theodore; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

6.  Computed tomography for imaging the breast.

Authors:  John M Boone; Alex L C Kwan; Kai Yang; George W Burkett; Karen K Lindfors; Thomas R Nelson
Journal:  J Mammary Gland Biol Neoplasia       Date:  2006-04       Impact factor: 2.673

Review 7.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

8.  Dedicated breast computed tomography: volume image denoising via a partial-diffusion equation based technique.

Authors:  Jessie Q Xia; Joseph Y Lo; Kai Yang; Carey E Floyd; John M Boone
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

9.  Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery.

Authors:  S Reaungamornrat; A S Wang; A Uneri; Y Otake; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-06-17       Impact factor: 3.609

10.  Geometric nonlinear diffusion filter and its application to X-ray imaging.

Authors:  Eric Michel-González; Min Hyoung Cho; Soo Yeol Lee
Journal:  Biomed Eng Online       Date:  2011-06-05       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.