Literature DB >> 20390461

Non-destructive natural frequency tests of cyclic fatigue-loaded nickel-titanium rotary instruments.

Sung-Chih Hsieh1, Sheng-Yang Lee, Chun-Yu Ciou, Haw-Ming Huang.   

Abstract

Nickel-titanium (NiTi) instruments are extensively used in endodontic treatment because of their outstanding mechanical properties. However, unexpected fracture of NiTi rotary instruments occurs during endodontic procedures. Therefore, a reliable method to detect the structural status of a used NiTi instrument is needed. The aim of this study is to use natural frequency for monitoring structural changes of a NiTi instrument during and after the instrumentation process. In this study, laboratory modal testing experiments were performed on cyclic fatigue-loaded NiTi rotary instruments with a natural frequency detecting device. In addition, three-dimensional finite element (FE) models were established for assessing the structural changes that take place in repeatedly loaded NiTi instruments. Repeated rotational loading resulted in a significant decrease (p < 0.05) in natural frequency (with a decreasing ratio of 5.6%) when the tested instruments reached 77-85% of their total life limit. In FE analysis, a strong correlation between natural frequency and change in elastic modulus of the NiTi instrument was found. These findings indicated that natural frequency may represent an effective parameter for evaluating the micro-structural status of NiTi rotary instruments subjected to fatigue loadings.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20390461     DOI: 10.1007/s11517-010-0605-2

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  18 in total

Review 1.  An overview of nickel-titanium alloys used in dentistry.

Authors:  S A Thompson
Journal:  Int Endod J       Date:  2000-07       Impact factor: 5.264

2.  The NiTi superelastic alloy application to the dentistry field.

Authors:  L Torrisi
Journal:  Biomed Mater Eng       Date:  1999       Impact factor: 1.300

3.  Evaluation of single-use rotary nickel-titanium instruments.

Authors:  F Charles Arens; Michael M Hoen; H Robert Steiman; Gerald C Dietz
Journal:  J Endod       Date:  2003-10       Impact factor: 4.171

4.  Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests.

Authors:  Uei-Ming Li; Bor-Shiunn Lee; Chin-Tsai Shih; Wan-Hong Lan; Chun-Pin Lin
Journal:  J Endod       Date:  2002-06       Impact factor: 4.171

5.  Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile.

Authors:  Elio Berutti; Giorgio Chiandussi; Ivan Gaviglio; Andrea Ibba
Journal:  J Endod       Date:  2003-01       Impact factor: 4.171

6.  Factors influencing the resonance frequency of dental implants.

Authors:  Haw-Ming Huang; Ching-Lai Chiu; Ching-Ying Yeh; Sheng-Yang Lee
Journal:  J Oral Maxillofac Surg       Date:  2003-10       Impact factor: 1.895

7.  Design of a stability-detecting device for dental implants.

Authors:  H M Huang; K Y Cheng; C F Chen; K L Ou; C T Li; S Y Lee
Journal:  Proc Inst Mech Eng H       Date:  2005-05       Impact factor: 1.617

8.  Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections.

Authors:  Xuejun Xu; M Eng; Yufeng Zheng; D Eng
Journal:  J Endod       Date:  2006-02-07       Impact factor: 4.171

9.  Mechanical behaviour of nickel-titanium rotary endodontic instruments in simulated clinical conditions: a computational study.

Authors:  S Necchi; S Taschieri; L Petrini; F Migliavacca
Journal:  Int Endod J       Date:  2008-11       Impact factor: 5.264

10.  Axial vibration of threaded external fixation pins: detection of pin loosening.

Authors:  M W Kay; S C Roe; L F Stikeleather; A Mahmoud; C F Abrams
Journal:  Ann Biomed Eng       Date:  1998 May-Jun       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.