Literature DB >> 15173778

Impact of photon energy recovery on the assessment of left ventricular volume using myocardial perfusion SPECT.

Alain Manrique1, Anne Hitzel, Pierre Véra.   

Abstract

BACKGROUND: Photon energy recovery (PER) is a spectral deconvolution technique validated for scatter removal in patients and phantom studies. The purpose of this study was to examine the impact of PER on left ventricular volume measurement based on myocardial perfusion single photon emission computed tomography (SPECT). METHODS AND
RESULTS: SPECT acquisitions were performed by use of a static cardiac phantom and in 25 patients after a rest injection of technetium 99m sestamibi by use of multiple energy windows (126-136, 137-144, and 145-154 keV). Data were successively reconstructed with and without PER, by use of iterative reconstruction and post-processing filtering (Butterworth filter; order, 5; cutoff, 0.30 cycles/pixel). Image contrast was evaluated in reconstructed data, and volumes were calculated by use of QGS. PER increased reconstructed image contrast from 62% +/- 2.7% to 84.3% +/- 5.7% in the phantom studies (P <.0001) and from 49% +/- 2% to 73% +/- 2% in patients (P <.0001). Although it remained underestimated (P <.0001), phantom volume was higher after PER correction compared with uncorrected data (50.9 +/- 0.8 mL vs 44.6 +/- 1 mL, P <.0001). The error in volume measurement was decreased by PER correction (16.6% +/- 1.3% vs 27% +/- 1.7% [uncorrected data], P <.0001). In patients, left ventricular volume increased from 83 +/- 10 mL to 91 +/- 10 mL (P <.0001), and the PER-induced volume increase was correlated with the image contrast increase (r = 0.61, P =.001). Finally, the percentage of volume increase was higher in patients with small left ventricular volumes.
CONCLUSIONS: PER has a significant impact on image contrast and left ventricular volume measurement by use of perfusion SPECT. PER improves the accuracy of phantom volume assessment. In patients, volume increase is correlated to image contrast increase and is higher in those with small ventricles.

Entities:  

Mesh:

Year:  2004        PMID: 15173778     DOI: 10.1016/j.nuclcard.2004.03.001

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  26 in total

1.  Gated SPET quantification of small hearts: mathematical simulation and clinical application.

Authors:  K Nakajima; J Taki; T Higuchi; M Kawano; M Taniguchi; K Maruhashi; S Sakazume; N Tonami
Journal:  Eur J Nucl Med       Date:  2000-09

2.  Development and application of normal limits for left ventricular ejection fraction and volume measurements from 99mTc-sestamibi myocardial perfusion gates SPECT.

Authors:  A Rozanski; K Nichols; S S Yao; S Malholtra; R Cohen; E G DePuey
Journal:  J Nucl Med       Date:  2000-09       Impact factor: 10.057

3.  Clinical validation of simultaneous dual-isotope myocardial scintigraphy.

Authors:  Pierre Weinmann; Marc Faraggi; Jean Luc Moretti; Pascal Hannequin
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-10-19       Impact factor: 9.236

4.  Reproducibility and accuracy of gated SPECT for determination of left ventricular volumes and ejection fraction: experimental validation using MRI.

Authors:  E Vallejo; D P Dione; W L Bruni; R T Constable; P P Borek; J P Soares; J G Carr; S G Condos; F J Wackers; A J Sinusas
Journal:  J Nucl Med       Date:  2000-05       Impact factor: 10.057

5.  Determination of the optimum filter function for SPECT imaging.

Authors:  D R Gilland; B M Tsui; W H McCartney; J R Perry; J Berg
Journal:  J Nucl Med       Date:  1988-05       Impact factor: 10.057

6.  Assessment of regional and global left ventricular function by reinjection T1-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with three-dimensional magnetic resonance imaging.

Authors:  E Tadamura; T Kudoh; M Motooka; M Inubushi; S Shirakawa; N Hattori; T Okada; T Matsuda; T Koshiji; K Nishimura; K Matsuda; J Konishi
Journal:  J Am Coll Cardiol       Date:  1999-03-15       Impact factor: 24.094

7.  Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations.

Authors:  I Buvat; M Rodriguez-Villafuerte; A Todd-Pokropek; H Benali; R Di Paola
Journal:  J Nucl Med       Date:  1995-08       Impact factor: 10.057

Review 8.  Scatter correction in scintigraphy: the state of the art.

Authors:  I Buvat; H Benali; A Todd-Pokropek; R Di Paola
Journal:  Eur J Nucl Med       Date:  1994-07

9.  Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.

Authors:  P Hannequin; P Weinmann; J Mas; S Vinot
Journal:  J Nucl Cardiol       Date:  2001 Mar-Apr       Impact factor: 5.952

10.  Impact of Wiener filter in determining the left ventricular volume and ejection fraction using thallium-201 gated SPECT.

Authors:  A Manrique; A Hitzel; I Gardin; J N Dacher; P Vera
Journal:  Nucl Med Commun       Date:  2003-08       Impact factor: 1.690

View more
  2 in total

Review 1.  Transplant allograft vasculopathy: Role of multimodality imaging in surveillance and diagnosis.

Authors:  Gregory A Payne; Fadi G Hage; Deepak Acharya
Journal:  J Nucl Cardiol       Date:  2015-12-28       Impact factor: 5.952

2.  Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: phantom study and clinical validation vs cardiac magnetic resonance.

Authors:  Alban Bailliez; Tanguy Blaire; Frédéric Mouquet; R Legghe; B Etienne; Damien Legallois; Denis Agostini; Alain Manrique
Journal:  J Nucl Cardiol       Date:  2014-05-09       Impact factor: 5.952

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.