Literature DB >> 15170781

Imaging of myocardial perfusion with magnetic resonance.

Jörg Barkhausen1, Peter Hunold, Markus Jochims, Jörg F Debatin.   

Abstract

Coronary artery disease (CAD) is currently the leading cause of death in developed nations. Reflecting the complexity of cardiac function and morphology, noninvasive diagnosis of CAD represents a major challenge for medical imaging. Although coronary artery stenoses can be depicted with magnetic resonance (MR) and computed tomography (CT) techniques, its functional or hemodynamic impact frequently remains elusive. Therefore, there is growing interest in other, target organ-specific parameters such as myocardial function at stress and first-pass myocardial perfusion imaging to assess myocardial blood flow. This review explores the pathophysiologic background, recent technical developments, and current clinical status of first-pass MR imaging (MRI) of myocardial perfusion. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15170781     DOI: 10.1002/jmri.20073

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  20 in total

1.  Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

Authors:  Ricardo Otazo; Daniel Kim; Leon Axel; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

Review 2.  Cardiovascular magnetic resonance and the evaluation of heart failure.

Authors:  James C C Moon; Sanjay K Prasad
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

3.  Assessment of myocardial perfusion and viability from routine contrast-enhanced 16-detector-row computed tomography of the heart: preliminary results.

Authors:  Konstantin Nikolaou; Javier Sanz; Michael Poon; Bernd J Wintersperger; Bernd Ohnesorge; Teresa Rius; Zahi A Fayad; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

4.  On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies.

Authors:  E V R Di Bella; D L Parker; A J Sinusas
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

Review 5.  Cardiovascular magnetic resonance: structure, function, perfusion, and viability.

Authors:  David C Isbell; Christopher M Kramer
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

Review 6.  Magnetic resonance approaches and recent advances in myocardial perfusion imaging.

Authors:  Daniel C Lee; Francis J Klocke
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

7.  High-resolution myocardial perfusion imaging at 3 T: comparison to 1.5 T in healthy volunteers.

Authors:  K Strach; C Meyer; D Thomas; C P Naehle; C Schmitz; H Litt; A Bernstein; B Cheng; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2007-02-16       Impact factor: 5.315

8.  High-resolution myocardial stress perfusion at 3 T in patients with suspected coronary artery disease.

Authors:  Carsten Meyer; Katharina Strach; Daniel Thomas; Harold Litt; Claas P Nähle; Klaus Tiemann; Ulrich Schwenger; Hans H Schild; Torsten Sommer
Journal:  Eur Radiol       Date:  2007-09-13       Impact factor: 5.315

9.  Dose response of the intravascular contrast agent gadofosveset trisodium in MR perfusion imaging of the myocardium using a quantitative evaluation.

Authors:  Sebastian Niedermayer; Steven Sourbron; Maria Prompona; Clemens Cyran; Maximilian Reiser; Armin Huber
Journal:  Int J Cardiovasc Imaging       Date:  2013-06-06       Impact factor: 2.357

10.  High resolution myocardial magnetic resonance stress perfusion imaging at 3 T using a 1 M contrast agent.

Authors:  Bernhard D Klumpp; Achim Seeger; Christina Doesch; Joerg Doering; Tobias Hoevelborn; Ulrich Kramer; Michael Fenchel; Meinrad P Gawaz; Claus D Claussen; Stephan Miller
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.