Literature DB >> 24399057

Early feasibility testing and engineering development of the transapical approach for the HeartWare MVAD ventricular assist system.

Daniel Tamez1, Jeffrey A LaRose, Charles Shambaugh, Katherine Chorpenning, Kevin G Soucy, Michael A Sobieski, Leslie Sherwood, Guruprasad A Giridharan, Gretel Monreal, Steven C Koenig, Mark S Slaughter.   

Abstract

Implantation of ventricular assist devices (VADs) for the treatment of end-stage heart failure (HF) falls decidedly short of clinical demand, which exceeds 100,000 HF patients per year. Ventricular assist device implantation often requires major surgical intervention with associated risk of adverse events and long recovery periods. To address these limitations, HeartWare, Inc. has developed a platform of miniature ventricular devices with progressively reduced surgical invasiveness and innovative patient peripherals. One surgical implant concept is a transapical version of the miniaturized left ventricular assist device (MVAD). The HeartWare MVAD Pump is a small, continuous-flow, full-support device that has a displacement volume of 22 ml. A new cannula configuration has been developed for transapical implantation, where the outflow cannula is positioned across the aortic valve. The two primary objectives for this feasibility study were to evaluate anatomic fit and surgical approach and efficacy of the transapical MVAD configuration. Anatomic fit and surgical approach were demonstrated using human cadavers (n = 4). Efficacy was demonstrated in acute (n = 2) and chronic (n = 1) bovine model experiments and assessed by improvements in hemodynamics, biocompatibility, flow dynamics, and histopathology. Potential advantages of the MVAD Pump include flow support in the same direction as the native ventricle, elimination of cardiopulmonary bypass, and minimally invasive implantation.

Entities:  

Mesh:

Year:  2014        PMID: 24399057      PMCID: PMC4120071          DOI: 10.1097/MAT.0000000000000038

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  16 in total

1.  A miniature intraventricular axial flow blood pump that is introduced through the left ventricular apex.

Authors:  K Yamazaki; M Umezu; H Koyanagi; M Kitamura; K Eishi; A Kawai; O Tagusari; H Niinami; T Akimoto; C Nojiri
Journal:  ASAIO J       Date:  1992 Jul-Sep       Impact factor: 2.872

2.  Catheter replacement of the needle in percutaneous arteriography; a new technique.

Authors:  S I SELDINGER
Journal:  Acta radiol       Date:  1953-05       Impact factor: 1.990

3.  Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation.

Authors:  Kenneth N Litwak; Steven C Koenig; Rolando C Cheng; Guruprasad A Giridharan; Kevin J Gillars; George M Pantalos
Journal:  Artif Organs       Date:  2005-08       Impact factor: 3.094

4.  Development of "plug and play" TransApical to aorta VAD.

Authors:  Dongfang Wang; Joseph B Zwischenberger; Xiaoqin Zhou; David Loran; Stephen Topaz; Christoph Nix; Kun-Xi Qian; Daniel L Traber; Willem J Kolff
Journal:  ASAIO J       Date:  2007 Mar-Apr       Impact factor: 2.872

Review 5.  Heart disease and stroke statistics--2013 update: a report from the American Heart Association.

Authors:  Alan S Go; Dariush Mozaffarian; Véronique L Roger; Emelia J Benjamin; Jarett D Berry; William B Borden; Dawn M Bravata; Shifan Dai; Earl S Ford; Caroline S Fox; Sheila Franco; Heather J Fullerton; Cathleen Gillespie; Susan M Hailpern; John A Heit; Virginia J Howard; Mark D Huffman; Brett M Kissela; Steven J Kittner; Daniel T Lackland; Judith H Lichtman; Lynda D Lisabeth; David Magid; Gregory M Marcus; Ariane Marelli; David B Matchar; Darren K McGuire; Emile R Mohler; Claudia S Moy; Michael E Mussolino; Graham Nichol; Nina P Paynter; Pamela J Schreiner; Paul D Sorlie; Joel Stein; Tanya N Turan; Salim S Virani; Nathan D Wong; Daniel Woo; Melanie B Turner
Journal:  Circulation       Date:  2012-12-12       Impact factor: 29.690

6.  Transapical left ventricular bypass.

Authors:  W J Kolff
Journal:  Arch Surg       Date:  1971-11

7.  Second INTERMACS annual report: more than 1,000 primary left ventricular assist device implants.

Authors:  James K Kirklin; David C Naftel; Robert L Kormos; Lynne W Stevenson; Francis D Pagani; Marissa A Miller; Karen L Ulisney; J Timothy Baldwin; James B Young
Journal:  J Heart Lung Transplant       Date:  2010-01       Impact factor: 10.247

8.  One-year mortality among unselected outpatients with heart failure.

Authors:  J Muntwyler; G Abetel; C Gruner; F Follath
Journal:  Eur Heart J       Date:  2002-12       Impact factor: 29.983

9.  An intraventricular axial flow blood pump integrated with a bearing purge system.

Authors:  K Yamazaki; R Kormos; T Mori; M Umezu; M Kameneva; J Antaki; E Outa; P Litwak; J Kerrigan; J Tomczak
Journal:  ASAIO J       Date:  1995 Jul-Sep       Impact factor: 2.872

10.  Heart disease and stroke statistics--2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee.

Authors:  Wayne Rosamond; Katherine Flegal; Karen Furie; Alan Go; Kurt Greenlund; Nancy Haase; Susan M Hailpern; Michael Ho; Virginia Howard; Brett Kissela; Bret Kissela; Steven Kittner; Donald Lloyd-Jones; Mary McDermott; James Meigs; Claudia Moy; Graham Nichol; Christopher O'Donnell; Veronique Roger; Paul Sorlie; Julia Steinberger; Thomas Thom; Matt Wilson; Yuling Hong
Journal:  Circulation       Date:  2007-12-17       Impact factor: 29.690

View more
  7 in total

Review 1.  Artificial hearts-recent progress: republication of the article published in the Japanese Journal of Artificial Organs.

Authors:  Masahiro Nishida
Journal:  J Artif Organs       Date:  2017-06-15       Impact factor: 1.731

Review 2.  State of the art of mechanical circulatory support.

Authors:  Hari R Mallidi; Jatin Anand; William E Cohn
Journal:  Tex Heart Inst J       Date:  2014-04-01

Review 3.  Ventricular Assist Devices - Evolution of Surgical Heart Failure Treatment.

Authors:  Dominik Wiedemann; Thomas Haberl; Julia Riebandt; Paul Simon; Günther Laufer; Daniel Zimpfer
Journal:  Eur Cardiol       Date:  2014-07

4.  A transapical-to-aorta double lumen cannula-based neonate left ventricular assist device efficiently unloads the left ventricle in neonate lambs.

Authors:  Cheng Zhou; Dongfang Wang; Cherry Ballard-Croft; Guangfeng Zhao; Hassan K Reda; Stephen Topaz; Joseph Zwischenberger
Journal:  J Thorac Cardiovasc Surg       Date:  2016-08-31       Impact factor: 5.209

Review 5.  New drugs and devices in the pipeline for heart failure with reduced ejection fraction versus heart failure with preserved ejection fraction.

Authors:  Amresh Raina; Manreet Kanwar
Journal:  Curr Heart Fail Rep       Date:  2014-12

6.  Dynamic measurement of centering forces on transvalvular cannulas.

Authors:  Martin Stoiber; Philipp Aigner; Christian Grasl; Michael Röhrich; Francesco Moscato; Heinrich Schima
Journal:  Artif Organs       Date:  2019-12-11       Impact factor: 3.094

7.  Control Strategy Design of a Microblood Pump Based on Heart-Rate Feedback.

Authors:  Teng Jing; Tianye Xin; Fangqun Wang; Zhihao Zhang; Ling Zhou
Journal:  Micromachines (Basel)       Date:  2022-02-24       Impact factor: 2.891

  7 in total