Literature DB >> 15145132

The influence of physical stent parameters upon restenosis.

Allison C Morton1, David Crossman, Julian Gunn.   

Abstract

In this paper we examine whether the structure, geometry and dimensions of coronary stents influence the occurrence of restenosis. Whilst many consider these parameters to be less important since the advent of drug-eluting stents, this view reveals a poor appreciation of the technological development of stents over the last 18 years. Early 'slotted tube' stents were completely inflexible and posed major problems for delivery; and early 'coil' stents had poor radial strength, allowing considerable tissue prolapse. Nowadays, we are used to greatly improved physical stent parameters, which provide better deliverability, visibility, procedural success and scaffolding performance. Many of these physical parameters also impact upon restenosis, even in the current era of drug-eluting stent. In this paper we examine the contribution of mode of expansion (self vs. balloon-expandable), design (coil vs. tube), length and width to restenosis. We also consider the more subtle influence of advanced slotted tube vs. modular design, percent metal coverage, strut thickness, strut shape, surface smoothness and alloy composition.

Entities:  

Mesh:

Year:  2004        PMID: 15145132     DOI: 10.1016/j.patbio.2004.03.013

Source DB:  PubMed          Journal:  Pathol Biol (Paris)        ISSN: 0369-8114


  12 in total

1.  Mechanical behavior of fully expanded commercially available endovascular coronary stents.

Authors:  Josip Tambaca; Suncica Canic; Mate Kosor; R David Fish; David Paniagua
Journal:  Tex Heart Inst J       Date:  2011

2.  Drug-eluting stents.

Authors:  Xiaodong Ma; Tim Wu; Michael P Robich; Xingwei Wang; Hao Wu; Bryan Buchholz; Stephen McCarthy
Journal:  Int J Clin Exp Med       Date:  2010-07-15

3.  Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis.

Authors:  Houman Zahedmanesh; Caitríona Lally
Journal:  Med Biol Eng Comput       Date:  2009-02-03       Impact factor: 2.602

4.  Overaggressive stent expansion without intravascular imaging: impact on restenosis.

Authors:  Yohan Chacko; Richard Chan; J Kimberly Haladyn; Richard Lim
Journal:  Heart Asia       Date:  2014-02-27

5.  Computational simulation methodologies for mechanobiological modelling: a cell-centred approach to neointima development in stents.

Authors:  C J Boyle; A B Lennon; M Early; D J Kelly; C Lally; P J Prendergast
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2010-06-28       Impact factor: 4.226

Review 6.  A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications.

Authors:  Mehdi Jafary-Zadeh; Gideon Praveen Kumar; Paulo Sergio Branicio; Mohsen Seifi; John J Lewandowski; Fangsen Cui
Journal:  J Funct Biomater       Date:  2018-02-27

7.  Flexibility of Biodegradable Polymer Stents with Different Strut Geometries.

Authors:  Chong Chen; Yan Xiong; Zhongyou Li; Yu Chen
Journal:  Materials (Basel)       Date:  2020-07-27       Impact factor: 3.623

8.  Treatment of infrapopliteal post-PTA dissection with tack implants: 12-month results from the TOBA-BTK study.

Authors:  Marianne Brodmann; Christian Wissgott; Andrew Holden; Robert Staffa; Thomas Zeller; Thodur Vasudevan; Peter Schneider
Journal:  Catheter Cardiovasc Interv       Date:  2018-03-24       Impact factor: 2.692

9.  Prospective evaluation of an ultrathin strut biodegradable polymer-coated sirolimus-eluting stent: 12 months' results from the S-FLEX UK registry.

Authors:  Anirban Choudhury; Scot Garg; Jamie Smith; Andrew Sharp; Sergio Nabais de Araujo; Anoop Chauhan; Nikhil Patel; Benjamin Wrigley; Sudipta Chattopadhyay; Azfar G Zaman
Journal:  BMJ Open       Date:  2019-10-11       Impact factor: 2.692

10.  Real-World Use Of Ultrathin-Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents In Patients With Coronary Artery Disease: 6-Month Clinical Outcomes.

Authors:  Prakash Ajmera; Ramesh Pothineni; Kamal Kumar Chawla; Sai Sudhakar Mantravadi; Pankaj Vinod Jariwala; Vinod Vijan; Vikrant Vijan
Journal:  Vasc Health Risk Manag       Date:  2019-10-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.