Literature DB >> 15125721

The use of a modified sphygmomanometer to detect atrial fibrillation in outpatients.

Joseph Wiesel1, David Wiesel, Ranjit Suri, Frank C Messineo.   

Abstract

This study was designed to assess the accuracy of a modified sphygmomanometer, that measures pulse irregularity, to detect atrial fibrillation (AF). An irregularity index, defined as the standard deviation of the time intervals between beats divided by the mean of the time intervals, was used to analyze standard 12-lead ECGs from hospitalized patients. A threshold irregularity index was selected such that all ECGs with AF exceeded this irregularity index value. A modified automatic blood pressure monitor was designed to detect AF by calculating the irregularity index of the pulse. The device was used to calculate the irregularity index in an unselected group of outpatients during scheduled office visits in which a standard 12-lead ECG was performed. A total of 125 ECGs, 53 with AF, were analyzed. Using a threshold irregularity index of 0.066, the sensitivity for detecting AF was 100%, the specificity was 92% and diagnostic accuracy 95%. A modified sphygmomanometer was used to analyze the pulse of 450 outpatients, 54 of whom were documented by ECG to be in AF. When paired readings were analyzed, the rhythm was considered to be irregular if both readings were greater than the threshold index. Using a threshold index of 0.06, all the AF patients were correctly identified while 37 non-AF patients also exceeded the threshold irregularity index. In this analysis, the sensitivity was 100%, the specificity 91%, and the diagnostic accuracy 92% for detecting AF. The irregularity index determined using a modified sphygmomanometer can accurately identify AF.

Entities:  

Mesh:

Year:  2004        PMID: 15125721     DOI: 10.1111/j.1540-8159.2004.00499.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  15 in total

1.  Screening for Atrial Fibrillation During Automatic Blood Pressure Measurements.

Authors:  Andrew Lowe; Timothy H Oh; Ralph Stewart
Journal:  IEEE J Transl Eng Health Med       Date:  2018-10-09       Impact factor: 3.316

2.  Validation of a simple method for atrial fibrillation screening in patients with stroke.

Authors:  C Gandolfo; M Balestrino; C Bruno; C Finocchi; N Reale
Journal:  Neurol Sci       Date:  2015-04-30       Impact factor: 3.307

3.  Atrial fibrillation screening during automated blood pressure measurement-Comment on "Diagnostic accuracy of new algorithm to detect atrial fibrillation in a home blood pressure monitor".

Authors:  Yi Chen; Lei Lei; Ji-Guang Wang
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-09-24       Impact factor: 3.738

Review 4.  Accuracy of methods for detecting an irregular pulse and suspected atrial fibrillation: A systematic review and meta-analysis.

Authors:  Jaspal S Taggar; Tim Coleman; Sarah Lewis; Carl Heneghan; Matthew Jones
Journal:  Eur J Prev Cardiol       Date:  2015-10-13       Impact factor: 7.804

5.  Accuracy of pulse interval timing in ambulatory blood pressure measurement.

Authors:  Sarah A Kane; James R Blake; Frank J McArdle; Philip Langley; Andrew J Sims
Journal:  Sci Rep       Date:  2016-11-23       Impact factor: 4.379

6.  Diagnostic performance of an automatic blood pressure measurement device, Microlife WatchBP Home A, for atrial fibrillation screening in a real-world primary care setting.

Authors:  Pak-Hei Chan; Chun-Ka Wong; Louise Pun; Yu-Fai Wong; Michelle Man-Ying Wong; Daniel Wai-Sing Chu; Chung-Wah Siu
Journal:  BMJ Open       Date:  2017-06-15       Impact factor: 2.692

7.  WatchBP Home A for opportunistically detecting atrial fibrillation during diagnosis and monitoring of hypertension: a NICE Medical Technology Guidance.

Authors:  Iain Willits; Kim Keltie; Joyce Craig; Andrew Sims
Journal:  Appl Health Econ Health Policy       Date:  2014-06       Impact factor: 2.561

8.  Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review.

Authors:  Sarah A Kane; James R Blake; Frank J McArdle; Philip Langley; Andrew J Sims
Journal:  Open Heart       Date:  2016-04-12

9.  Opportunistic screening of atrial fibrillation by automatic blood pressure measurement in the community.

Authors:  Stefano Omboni; Willem J Verberk
Journal:  BMJ Open       Date:  2016-04-12       Impact factor: 2.692

10.  Detection of Atrial Fibrillation Using a Home Blood Pressure Monitor.

Authors:  Thomas Balanis; Bernd Sanner
Journal:  Vasc Health Risk Manag       Date:  2021-07-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.