Radiographic assessment of cementless femoral components. Correlation with intraoperative mechanical stability.

E J Vresilovic1, W J Hozack, R H Rothman.   

Abstract

The correlation between preoperative radiographic findings and intraoperative testing for stability was evaluated for 75 cementless femoral components. Fourteen of 45 porous-coated prostheses were unstable. The following radiographic signs were correlated with instability in order of significance: radiolucent lines at the bone-prosthesis interface covering greater than 50% of the porous interface, a distal pedestal, calcar hypertrophy, poor implant-cortical contact, and varus component alignment. Signs consistent with implant stability were good implant-cortical contact, spot welds, and calcar atrophy. Preoperative radiographs have predictive value in assessing the mechanical stability of the cementless femoral component at the time of surgery.

Entities:  

Mesh:

Year:  1994        PMID: 8014644     DOI: 10.1016/0883-5403(94)90062-0

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  22 in total

1.  Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

Authors:  M Viceconti; A Pancanti; M Dotti; F Traina; L Cristofolini
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

2.  Pedestal sign in cementless total hip replacement.

Authors:  F Agathangelidis; A Boutsiadis; G Petsatodis
Journal:  Hippokratia       Date:  2014 Oct-Dec       Impact factor: 0.471

3.  The effect of flexion alignment in total hip arthroplasty with a cementless tapered-wedge femoral stem.

Authors:  Junya Yoshitani; Tamon Kabata; Yoshitomo Kajino; Tomoharu Takagi; Takaaki Ohmori; Takuro Ueno; Ken Ueoka; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-06-27

4.  Effect of surgeon fatigue on hip and knee arthroplasty.

Authors:  Christopher Peskun; David Walmsley; James Waddell; Emil Schemitsch
Journal:  Can J Surg       Date:  2012-04       Impact factor: 2.089

5.  Mechanical and biological results of short-stem hip implants: consideration on a series of 74 cases.

Authors:  S Barreca; L Ciriaco; M Ferlazzo; M A Rosa
Journal:  Musculoskelet Surg       Date:  2014-06-27

6.  Changes of periprosthetic bone density after a cementless short hip stem: a clinical and radiological analysis.

Authors:  Alexander Jahnke; Sandra Engl; Corinna Altmeyer; Eike Jakubowitz; Jörn Bengt Seeger; Markus Rickert; Bernd Alexander Ishaque
Journal:  Int Orthop       Date:  2014-06-11       Impact factor: 3.075

7.  Clinical and radiological short-term complications after single-stage bilateral uncemented total hip arthroplasty.

Authors:  J Lamo-Espinosa; S Troncoso; A Valentí-Azcárate; P Díaz de Rada; J R Valentí-Nín
Journal:  Musculoskelet Surg       Date:  2014-11-27

8.  Bone mineral density as a marker of hip implant longevity: a prospective assessment of a cementless stem with dual-energy X-ray absorptiometry at twenty years.

Authors:  Giuseppe Sessa; Luciano Costarella; Calogero Puma Pagliarello; Antonio Di Stefano; Andrea Sessa; Gianluca Testa; Vito Pavone
Journal:  Int Orthop       Date:  2018-10-03       Impact factor: 3.075

9.  Osseointegration in arthroplasty: can simvastatin promote bone response to implants?

Authors:  Kerem Başarir; Bülent Erdemli; Alp Can; Esra Erdemli; Tuğba Zeyrek
Journal:  Int Orthop       Date:  2007-12-21       Impact factor: 3.075

10.  Surgeons changing the approach for total hip arthroplasty from posterior to direct anterior with fluoroscopy should consider potential excessive cup anteversion and flexion implantation of the stem in their early experience.

Authors:  Hideo Kobayashi; Yasuhiro Homma; Tomonori Baba; Hironori Ochi; Mikio Matsumoto; Takahito Yuasa; Kazuo Kaneko
Journal:  Int Orthop       Date:  2015-12-04       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.