Literature DB >> 15118845

Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging.

Allan Johansen1, Peter Grupe, Annegrete Veje, Poul-Erik Nielsen Braad, Poul Flemming Høilund-Carlsen.   

Abstract

Attenuation correction may improve the diagnostic accuracy of myocardial perfusion imaging (MPI). However, few studies have dealt with the clinical consequences for reporting. We compared routine reports based on scatter-corrected MPI (MPI-routine) with consensus readings of scatter-corrected (MPI-scatter) and scatter plus attenuation-corrected studies (MPI-attenuation) to investigate the impact of attenuation correction on reporting. One hundred consecutive stable angina patients (including 55 men) were investigated in a 99mTc-sestamibi 2-day gated protocol with scatter and attenuation correction. With MPI-routine, 53 patients had normal perfusion and 47 abnormal perfusion, compared to 62 and 38 with MPI-attenuation, and 54 and 46, respectively, with MPI-scatter. Agreement between MPI-routine and MPI-attenuation with respect to overall diagnosis (normal/abnormal perfusion) was 89% (kappa=0.78) compared to 95% (kappa=0.90) between MPI-routine and MPI-scatter. With MPI-attenuation, the overall routine diagnosis changed in 11 patients, of which ten cases were judged normal after scatter plus attenuation correction. The majority of the "normalised" studies were among patients with apparently single-vessel RCA disease as judged from MPI. Agreement rates with regard to normal, reversible or irreversible defects between MPI-attenuation and MPI-routine for the LAD, LCX and RCA territories were 88%, 97% and 85%, respectively, without significant sex differences. In conclusion, attenuation correction caused a change in diagnosis in approximately 10% of the patients, corresponding to one-fifth of the abnormal studies. In all but one case, the shift was from abnormal to normal, mostly because of a different interpretation in the RCA territory.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15118845     DOI: 10.1007/s00259-004-1481-5

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  34 in total

Review 1.  Contributions of nuclear cardiology to diagnosis and prognosis of patients with coronary artery disease.

Authors:  G A Beller; B L Zaret
Journal:  Circulation       Date:  2000-03-28       Impact factor: 29.690

2.  Clinical impact of combination of scatter, attenuation correction, and depth-dependent resolution recovery for (201)Tl studies.

Authors:  F Harel; R Génin; D Daou; R Lebtahi; N Delahaye; B O Helal; D Le Guludec; M Faraggi
Journal:  J Nucl Med       Date:  2001-10       Impact factor: 10.057

3.  A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models.

Authors:  Michael K O'connor; Brad Kemp; Frank Anstett; Paul Christian; Edward P Ficaro; Eric Frey; Mark Jacobs; James N Kritzman; Robert A Pooley; Michael Wilk
Journal:  J Nucl Cardiol       Date:  2002 Jul-Aug       Impact factor: 5.952

4.  Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormalities.

Authors:  H J Gallowitsch; J Sykora; P Mikosch; E Kresnik; O Unterweger; M Molnar; G Grimm; P Lind
Journal:  Eur J Nucl Med       Date:  1998-03

5.  Impact of attenuation correction by simultaneous emission/transmission tomography on visual assessment of 201Tl myocardial perfusion images.

Authors:  R Vidal; I Buvat; J Darcourt; O Migneco; P Desvignes; M Baudouy; F Bussière
Journal:  J Nucl Med       Date:  1999-08       Impact factor: 10.057

Review 6.  Radionuclide perfusion imaging techniques for evaluation of patients with known or suspected coronary artery disease.

Authors:  G A Beller
Journal:  Adv Intern Med       Date:  1997

7.  Limited incremental diagnostic values of attenuation-noncorrected gating and ungated attenuation correction to rest/stress myocardial perfusion SPECT in patients with an intermediate likelihood of coronary artery disease.

Authors:  D S Lee; Y So; G J Cheon; K M Kim; M M Lee; J K Chung; M C Lee
Journal:  J Nucl Med       Date:  2000-05       Impact factor: 10.057

8.  Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution.

Authors:  E P Ficaro; J A Fessler; R J Ackermann; W L Rogers; J R Corbett; M Schwaiger
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

Review 9.  Myocardial perfusion imaging during pharmacologic stress testing.

Authors:  J J Mahmarian; M S Verani
Journal:  Cardiol Clin       Date:  1994-05       Impact factor: 2.213

10.  Interpretive reproducibility of stress Tc-99m sestamibi tomographic myocardial perfusion imaging.

Authors:  R J Golub; A W Ahlberg; J R McClellan; S D Herman; M I Travin; J F Mather; P W Aitken; J I Baron; G V Heller
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

View more
  5 in total

1.  Diagnostic accuracy of myocardial perfusion imaging in a study population without post-test referral bias.

Authors:  Allan Johansen; Poul Flemming Høilund-Carlsen; Henrik Wulff Christensen; Werner Vach; Henrik Boel Jørgensen; Annegrete Veje; Torben Haghfelt
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

2.  A further step towards getting cardiac respiratory motion under control.

Authors:  Andreas A Giannopoulos; Ronny R Buechel
Journal:  J Nucl Cardiol       Date:  2017-02-28       Impact factor: 5.952

3.  Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction.

Authors:  Jei-Yie Huang; Ruoh-Fang Yen; Wen-Chung Lee; Chun-Kai Huang; Pei-Ying Hsu; Mei-Fang Cheng; Ching-Chu Lu; Yen-Hung Lin; Kuo-Liong Chien; Yen-Wen Wu
Journal:  J Nucl Cardiol       Date:  2018-02-26       Impact factor: 5.952

4.  Is radionuclide transmission scanning obsolete for dual-modality PET/CT systems?

Authors:  Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06       Impact factor: 10.057

5.  The Value of Attenuation Correction in Hybrid Cardiac SPECT/CT on Inferior Wall According to Body Mass Index.

Authors:  Muge Tamam; Mehmet Mulazimoglu; Nurcan Edis; Tevfik Ozpacaci
Journal:  World J Nucl Med       Date:  2016 Jan-Apr
  5 in total