Literature DB >> 15096971

Assessment of cardiac wall motion and ejection fraction with gated PET using N-13 ammonia.

Kathleen T Hickey1, Robert R Sciacca, Sabahat Bokhari, Oswaldo Rodriguez, Ru-Ling Chou, Tracy L Faber, C David Cooke, Ernest V Garcia, Kenneth Nichols, Steven R Bergmann.   

Abstract

BACKGROUND: Cardiac gating is not routinely used in cardiac positron emission tomography (PET). The aim of this study was to determine the feasibility of assessing regional wall motion, ejection fraction (EF), cardiac volumes, and mass with nitrogen-13 ammonia (N-13 ammonia) at the time of PET myocardial perfusion imaging.
METHODS: We studied 12 healthy volunteers (mean age, 28 +/- 8 years) and 53 patients with documented coronary artery disease (CAD) (mean age, 59 +/- 11 years). All subjects received a single administration of approximately 600 MBq (16 mCi) of N-13 ammonia intravenously. A 6-minute dynamic scan was performed for quantitative assessment of myocardial perfusion at rest, followed by a separate, 13-minute static scan acquired in the gated mode (8 equal bins). Gated data was imported into the Emory Toolbox. Wall motion was evaluated by dividing the myocardium into 9 anatomic regions graded semiquantitatively.
RESULTS: Healthy volunteers had a normal EF (61 +/- 6), end systolic volume (ESV) (37 +/- 15 mL), end diastolic volume (EDV) (89 +/- 25 mL), and cardiac mass (116 +/- 18 g). In contrast, patients with CAD showed reduced EF (32 +/- 13%) and increased ESV (129 +/- 56 mL), EDV (188 +/- 68 mL), and cardiac mass (173 +/- 45 g) (P < 0.001 for each). In patients with CAD, EF measured by gated PET correlated significantly to independent measurements of EF (P < 0.001).
CONCLUSIONS: Gating of cardiac perfusion images obtained after administration of N-13 ammonia is feasible and appears to be an accurate means of evaluating regional and global cardiac function. Gating can provide important additional diagnostic and prognostic information.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15096971     DOI: 10.1097/01.rlu.0000118001.14457.c3

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  13 in total

1.  Partial volume correction incorporating Rb-82 positron range for quantitative myocardial perfusion PET based on systolic-diastolic activity ratios and phantom measurements.

Authors:  Nils P Johnson; Stefano Sdringola; K Lance Gould
Journal:  J Nucl Cardiol       Date:  2010-12-24       Impact factor: 5.952

2.  Measurement of left ventricular volumes and function using O-15-labeled carbon monoxide gated PET.

Authors:  Philipp A Kaufmann
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

3.  Measurement of left ventricular volumes and function with O-15-labeled carbon monoxide gated positron emission tomography: comparison with magnetic resonance imaging.

Authors:  Hadassa A Hofman; Paul Knaapen; Ronald Boellaard; Olga Bondarenko; Marco J W Götte; Willem G van Dockum; Cees A Visser; Albert C van Rossum; Adriaan A Lammertsma; Frans C Visser
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

4.  Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

Authors:  Chuan Huang; Yoann Petibon; Jinsong Ouyang; Timothy G Reese; Mark A Ahlman; David A Bluemke; Georges El Fakhri
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

Review 5.  Assessment of myocardial perfusion and function with PET and PET/CT.

Authors:  Mouaz H Al-Mallah; Arkadiusz Sitek; Stephen C Moore; Marcelo Di Carli; Sharmila Dorbala
Journal:  J Nucl Cardiol       Date:  2010-06       Impact factor: 5.952

6.  Myocardial blood flow and left ventricular functional reserve in hypertrophic cardiomyopathy: a 13NH3 gated PET study.

Authors:  Roberto Sciagrà; Raffaella Calabretta; Fabrizio Cipollini; Alessandro Passeri; Angelo Castello; Franco Cecchi; Iacopo Olivotto; Alberto Pupi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-01-03       Impact factor: 9.236

7.  An improved model for the measurement of myocardial perfusion in human beings using N-13 ammonia.

Authors:  Kathleen T Hickey; Robert R Sciacca; Ru-Ling Chou; Oswaldo Rodriguez; Sabahat Bokhari; Steven R Bergmann
Journal:  J Nucl Cardiol       Date:  2005 May-Jun       Impact factor: 5.952

8.  The development and initial evaluation of a realistic simulated SPECT dataset with simultaneous respiratory and cardiac motion for gated myocardial perfusion SPECT.

Authors:  Taek-Soo Lee; Benjamin M W Tsui
Journal:  Phys Med Biol       Date:  2015-01-22       Impact factor: 3.609

9.  Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study.

Authors:  Y Petibon; J Ouyang; X Zhu; C Huang; T G Reese; S Y Chun; Q Li; G El Fakhri
Journal:  Phys Med Biol       Date:  2013-03-08       Impact factor: 3.609

10.  Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated (82)rubidium myocardial perfusion PET.

Authors:  Tracy L Y Brown; Jennifer Merrill; Lana Volokh; Frank M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-02       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.