Literature DB >> 1509620

Noninvasive measurement of diameter changes in the distal abdominal aorta in man.

T Länne1, H Stale, H Bengtsson, D Gustafsson, D Bergqvist, B Sonesson, H Lecerof, P Dahl.   

Abstract

An ultrasound phase-locked, echo-tracking system was used to determine the dynamic properties of the distal abdominal aorta in 10 Caucasian male subjects (mean age, 25 years). Recordings were made at rest and during the blood pressure increase resulting from isometric exercise. The pressure diameter curve was nonlinear with an inflection at about 90-110 mmHg. Above this pressure range, the vessel was stiffer (less compliant), but the pressure diameter relationship was roughly linear above as well as below the inflection. Individual pressure diameter curves showed hysteresis, i.e., the aorta had a smaller diameter during expansion than during retraction at corresponding pressures. The pressure strain elastic modulus (Ep) and stiffness (beta) were at rest [Mean Arterial Pressure (MAP), 81 mmHg] 0.70 10(5) N/m2 and 6.0, respectively. During isometric exercise (MAP, 122 mmHg), Ep increased significantly by 91% and stiffness (beta) nonsignificantly by 27%. The variability of the compliance determinations was 5% when the ultrasonic system was combined with intra-arterial blood pressure measurements and less than 7% when combined with auscultatory blood pressure measurements. It is concluded that the phase-locked, echo-tracking system fulfills clinical requirements for routine measurements of vascular compliance.

Entities:  

Mesh:

Year:  1992        PMID: 1509620     DOI: 10.1016/0301-5629(92)90084-n

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

1.  Application of dynamic computed tomography for measurements of local aortic elastic modulus.

Authors:  M K Lee; M Drangova; D W Holdsworth; A Fenster
Journal:  Med Biol Eng Comput       Date:  1999-01       Impact factor: 2.602

2.  Mathematical Model analysis of Wallstent and Aneurx: dynamic responses of bare-metal endoprosthesis compared with those of stent-graft.

Authors:  Suncica Canic; K Ravi-Chandar; Zvonimir Krajcer; Dragan Mirkovic; Serguei Lapin
Journal:  Tex Heart Inst J       Date:  2005

Review 3.  Aortic root dynamics and surgery: from craft to science.

Authors:  Allen Cheng; Paul Dagum; D Craig Miller
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2007-08-29       Impact factor: 6.237

Review 4.  Transesophageal Doppler devices: A technical review.

Authors:  Patrick Schober; Stephan A Loer; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2009-10-20       Impact factor: 2.502

5.  Effect of acute high-intensity resistance exercise on optic nerve sheath diameter and ophthalmic artery blood flow pulsatility.

Authors:  W K Lefferts; W E Hughes; K S Heffernan
Journal:  J Hum Hypertens       Date:  2015-03-05       Impact factor: 3.012

6.  Aortic arch compliance and idiopathic unilateral vocal fold paralysis.

Authors:  Reza Behkam; Kara E Roberts; Andrew J Bierhals; M Eileen Jacobs; Julia D Edgar; Randal C Paniello; Gayle Woodson; Jonathan P Vande Geest; Julie M Barkmeier-Kraemer
Journal:  J Appl Physiol (1985)       Date:  2017-05-18

7.  Measurement of nonlinear property of artery wall using remote cyclic actuation.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2006-09       Impact factor: 1.314

8.  Increased arterial stiffness in women, but not in men, with IDDM.

Authors:  A Rydén Ahlgren; T Länne; P Wollmer; B Sonesson; F Hansen; G Sundkvist
Journal:  Diabetologia       Date:  1995-09       Impact factor: 10.122

Review 9.  New strategies for energy supply of cardiac implantable devices.

Authors:  Caroline Moerke; Anne Wolff; Hüseyin Ince; Jasmin Ortak; Alper Öner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2022-04-04
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.