Application of dynamic computed tomography for measurements of local aortic elastic modulus.

M K Lee1, M Drangova, D W Holdsworth, A Fenster.   

Abstract

A novel computed tomographic (CT) technique used for the instantaneous measurement of the dynamic elastic modulus of intact excised porcine aortic vessels subjected to physiological pressure waveforms is described. This system was comprised of a high resolution X-ray image intensifier based computed tomographic system with limiting spatial resolution of 3.2 mm-1 (for a 40 mm field of view) and a computer-controlled flow simulator. Utilising cardiac gating and computer control, a time-resolved sequence of 1 mm thick axial tomographic slices was obtained for porcine aortic specimens during one simulated cardiac cycle. With an image acquisition sampling interval of 16.5 ms, the time sequences of CT slices were able to quantify the expansion and contraction of the aortic wall during each phase of the cardiac cycle. Through superficial tagging of the adventitial surface of the specimens with wire markers, measurement of wall strain in specific circumferential sectors and subsequent calculations of localised dynamic elastic modulus were possible. The precision of circumferential measurements made from the CT images utilising a cluster-growing segmentation technique was approximately +/- 0.25 mm and allowed determination of the dynamic elastic modulus E(dyn) with a precision of +/- 8 kPa. Dynamic elastic modulus was resolved as a function of the harmonics of the physiological pressure waveform and as a function of the angular position around the vessel circumference. Application of this dynamic CT (DCT) technique to seven porcine thoracic aortic specimens produced a circumferential average (over all frequency components) E(dyn) of 373 +/- 29 kPa. This value was not statistically different (p < 0.05) from the values of 430 +/- 77 and 390 +/- 47 kPa obtained by uniaxial tensile testing and volumetric measurements respectively.

Entities:  

Mesh:

Year:  1999        PMID: 10396836     DOI: 10.1007/bf02513260

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  38 in total

1.  Tracking and finite element analysis of stripe deformation in magnetic resonance tagging.

Authors:  A A Young; D L Kraitchman; L Dougherty; L Axel
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

2.  Assessment of the distensibility of superficial arteries.

Authors:  A P Hoeks; P J Brands; F A Smeets; R S Reneman
Journal:  Ultrasound Med Biol       Date:  1990       Impact factor: 2.998

3.  Dimensions and mechanical properties of porcine aortic segments determined by combined impedance planimetry and high-frequency ultrasound.

Authors:  J H Storkholm; G E Villadsen; K Krogh; C S Jørgensen; H Gregersen
Journal:  Med Biol Eng Comput       Date:  1997-01       Impact factor: 2.602

4.  Biomechanics of the arterial wall under simulated flow conditions.

Authors:  A M Brant; S S Shah; V G Rodgers; J Hoffmeister; I M Herman; R L Kormos; H S Borovetz
Journal:  J Biomech       Date:  1988       Impact factor: 2.712

5.  Dynamic deformation experiments on aortic tissue.

Authors:  R Collins; W C Hu
Journal:  J Biomech       Date:  1972-07       Impact factor: 2.712

6.  Pressure-flow relationships in the ascending aorta and femoral artery of man.

Authors:  D J Patel; J C Greenfield; W G Austen; A G Morrow; D L Fry
Journal:  J Appl Physiol       Date:  1965-05       Impact factor: 3.531

7.  Porcine pulmonary and aortic valves: a comparison of their tensile viscoelastic properties at physiological strain rates.

Authors:  J Leeson-Dietrich; D Boughner; I Vesely
Journal:  J Heart Valve Dis       Date:  1995-01

8.  Flexible hydraulic simulator for cardiovascular studies.

Authors:  M M Werneck; N B Jones; J Morgon
Journal:  Med Biol Eng Comput       Date:  1984-01       Impact factor: 2.602

9.  The elasticity of canine and human coronary arteries with reference to postmortem changes.

Authors:  B S Gow; C D Hadfield
Journal:  Circ Res       Date:  1979-11       Impact factor: 17.367

10.  A comparison of beam-hardening artifacts in x-ray computerized tomography with gadolinium and iodine contrast agents.

Authors:  C Ruth; P M Joseph
Journal:  Med Phys       Date:  1995-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.