Literature DB >> 9239502

Accuracy of the Vitek system for antimicrobial susceptibility testing Enterobacteriaceae bloodstream infection isolates: use of "direct" inoculation from Bactec 9240 blood culture bottles.

L R Putnam1, W J Howard, M A Pfaller, F P Koontz, R N Jones.   

Abstract

A recent investigation indicates that rapid antimicrobial susceptibility tests (AST) can affect patient therapy leading to reductions in health-care costs for some patient populations. However, there is little information relative to the often performed direct inoculation of positive blood culture bottles into rapid AST systems. AST results of direct inoculated Vitek (bioMerieux Vitek, Hazelwood, MO, USA) GNS cards were compared to those inoculated per package insert recommendations and a reference broth microdilution test using 50 consecutive Enterobacteriaceae bloodstream infection isolates. Escherichia coli (44% of isolates), Klebsiella ssp. (30%), and six other members of this family were tested against 15 antimicrobial agents. The direct inoculation method produced only two false-susceptible (0.3%), seven false-resistant (0.9%; six different drugs), and 48 minor errors (6.4%). The GNS cards inoculated in the usual, recommended manner had no very major error, and 7.5% combined major and minor errors. If the results of the urinary infection-specific drugs (nitrofurantoin, trimethoprim/sulfamethoxazole; not appropriate for bacteremia therapy) and ampicillin/sulbactam were deleted, both Vitek inoculation methods yielded results well within acceptable limits (< or = 4.5% overall error). These results indicate that the direct inoculation method of Vitek GNS cards from Enterobacteriaceae bloodstream infections (detected by Bactec 9240, Becton-Dickinson, Cockeysville, MD, USA) performed as well as the NCCLS broth microdilution test. Thus, a procedural modification of this type could further accelerate rapid access to accurate AST data.

Entities:  

Mesh:

Year:  1997        PMID: 9239502     DOI: 10.1016/s0732-8893(97)00014-x

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  10 in total

1.  Direct susceptibility testing of positive blood cultures by using Sensititre broth microdilution plates.

Authors:  Kimberle C Chapin; Michael C Musgnug
Journal:  J Clin Microbiol       Date:  2003-10       Impact factor: 5.948

2.  Use of positive blood cultures for direct identification and susceptibility testing with the vitek 2 system.

Authors:  Marina de Cueto; Esther Ceballos; Luis Martinez-Martinez; Evelio J Perea; Alvaro Pascual
Journal:  J Clin Microbiol       Date:  2004-08       Impact factor: 5.948

3.  Use of the BD PHOENIX Automated Microbiology System for direct identification and susceptibility testing of gram-negative rods from positive blood cultures in a three-phase trial.

Authors:  Guido Funke; Pascale Funke-Kissling
Journal:  J Clin Microbiol       Date:  2004-04       Impact factor: 5.948

4.  Accuracy of identification and susceptibility results by direct inoculation of Vitek 2 cards from positive BACTEC cultures.

Authors:  J J Kerremans; W H F Goessens; H A Verbrugh; M C Vos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2004-12       Impact factor: 3.267

5.  Evaluation of the Merlin MICRONAUT system for rapid direct susceptibility testing of gram-positive cocci and gram-negative bacilli from positive blood cultures.

Authors:  Nele Wellinghausen; Tim Pietzcker; Sven Poppert; Syron Belak; Nicole Fieser; Melanie Bartel; Andreas Essig
Journal:  J Clin Microbiol       Date:  2007-01-03       Impact factor: 5.948

6.  Enteric fever in a 6-year-old traveler caused by Salmonella enterica serotypes Typhi and Paratyphi A: laboratory detection strategies and treatment options.

Authors:  Romney M Humphries; Nava Yeganeh; Kevin W Ward; M A Lewinski; Natascha Ching
Journal:  J Clin Microbiol       Date:  2010-10-27       Impact factor: 5.948

7.  Predominance of Enterobacteriaceae isolates in early positive anaerobic blood culture bottles in BacT/Alert system.

Authors:  Tzong-Shi Chiueh; Shih-Yi Lee; Sheng-Hui Tang; Jang-Jih Lu; Jun-Ren Sun
Journal:  J Clin Lab Anal       Date:  2013-01-24       Impact factor: 2.352

8.  Identification and susceptibility testing of Enterobacteriaceae and Pseudomonas aeruginosa by direct inoculation from positive BACTEC blood culture bottles into Vitek 2.

Authors:  Marjan J Bruins; Peter Bloembergen; Gijs J H M Ruijs; Maurice J H M Wolfhagen
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

9.  Comparison of novel rapid diagnostic of blood culture identification and antimicrobial susceptibility testing by Accelerate Pheno system and BioFire FilmArray Blood Culture Identification and BioFire FilmArray Blood Culture Identification 2 panels.

Authors:  Dorothy T T Sze; Candy C Y Lau; Tsz-Ming Chan; Edmond S K Ma; Bone S F Tang
Journal:  BMC Microbiol       Date:  2021-12-18       Impact factor: 3.605

10.  Rapid identification and antimicrobial susceptibility profiling of Gram-positive cocci in blood cultures with the Vitek 2 system.

Authors:  A Lupetti; S Barnini; B Castagna; A-L Capria; P H Nibbering
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2009-11-10       Impact factor: 3.267

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.