Literature DB >> 15013983

Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum.

Thomas B Martins1, Brian M Pasi, Christine M Litwin, Harry R Hill.   

Abstract

While modern immunoassays provide sensitive and specific means for the quantitation of cytokines in biological fluids, heterophile antibodies are still a well-recognized cause of interference in the measurement of cytokines in these assays. We have developed a multiplexed fluorescent microsphere immunoassay for the simultaneous quantification of 10 cytokines in only 75 microl of serum. During the development of this multiplexed assay, the amount of assay interference due to heterophile antibodies was also determined, and methods for detecting heterophile interference and minimizing its effect were incorporated into the assay. Heterophile antibodies resulted in significantly elevated cytokine values compared to those of normal blood bank samples. These falsely elevated values, and thus the components of the assay the heterophile antibodies were binding to, were identified through the use of internal controls. This information was then used to design assay-specific blockers and absorbents that were shown to significantly reduce falsely elevated cytokine values while not affecting the standard and control values. The fluorescent multiplexed microsphere-based immunoassay can be used to quantitate multiple cytokines from a single sample and should be a useful tool in furthering our understanding of the role of cytokines in disease processes.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15013983      PMCID: PMC371198          DOI: 10.1128/cdli.11.2.325-329.2004

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  19 in total

1.  Heterophile antibodies to bovine and caprine proteins causing false-positive human immunodeficiency virus type 1 and other enzyme-linked immunosorbent assay results.

Authors:  J H Willman; T B Martins; T D Jaskowski; H R Hill; C M Litwin
Journal:  Clin Diagn Lab Immunol       Date:  1999-07

Review 2.  Measurement of cytokines in clinical samples using immunoassays: problems and pitfalls.

Authors:  R E Banks
Journal:  Crit Rev Clin Lab Sci       Date:  2000-04       Impact factor: 6.250

3.  The influence of naturally occurring heterophilic anti-immunoglobulin antibodies on direct measurement of serum proteins using sandwich ELISAs.

Authors:  C Hennig; L Rink; U Fagin; W J Jabs; H Kirchner
Journal:  J Immunol Methods       Date:  2000-02-21       Impact factor: 2.303

4.  Multiplexed fluorescent bead-based immunoassays for quantitation of human cytokines in serum and culture supernatants.

Authors:  K L Kellar; R R Kalwar; K A Dubois; D Crouse; W D Chafin; B E Kane
Journal:  Cytometry       Date:  2001-09-01

5.  Heterophilic antibodies: a problem for all immunoassays.

Authors:  L M Boscato; M C Stuart
Journal:  Clin Chem       Date:  1988-01       Impact factor: 8.327

6.  Incidence and specificity of interference in two-site immunoassays.

Authors:  L M Boscato; M C Stuart
Journal:  Clin Chem       Date:  1986-08       Impact factor: 8.327

7.  Enhancement by N-hydroxysulfosuccinimide of water-soluble carbodiimide-mediated coupling reactions.

Authors:  J V Staros; R W Wright; D M Swingle
Journal:  Anal Biochem       Date:  1986-07       Impact factor: 3.365

8.  Interference by anti-immunoglobulin G antibodies in immunoradiometric assays of thyrotropin involving mouse monoclonal antibodies.

Authors:  M H Zweig; G Csako; C C Benson; B D Weintraub; B B Kahn
Journal:  Clin Chem       Date:  1987-06       Impact factor: 8.327

9.  Circulating antibodies to mouse monoclonal immunoglobulins in normal subjects--incidence, species specificity, and effects on a two-site assay for creatine kinase-MB isoenzyme.

Authors:  R J Thompson; A P Jackson; N Langlois
Journal:  Clin Chem       Date:  1986-03       Impact factor: 8.327

10.  Determination of cytokine responses using a multiplexed fluorescent microsphere immunoassay.

Authors:  Thomas B Martins; Brian M Pasi; Jerry W Pickering; Troy D Jaskowski; Christine M Litwin; Harry R Hill
Journal:  Am J Clin Pathol       Date:  2002-09       Impact factor: 2.493

View more
  23 in total

1.  Elimination of false-positive results in a luminex assay for pneumococcal antibodies.

Authors:  Jerry W Pickering; Matthew T Larson; Thomas B Martins; Susan S Copple; Harry R Hill
Journal:  Clin Vaccine Immunol       Date:  2009-11-18

2.  Improved specificity of a multiplex immunoassay for quantitation of anti-diphtheria toxin antibodies with the use of diphtheria toxoid.

Authors:  Pieter G M van Gageldonk; Christina von Hunolstein; Fiona R M van der Klis; Guy A M Berbers
Journal:  Clin Vaccine Immunol       Date:  2011-05-25

3.  Significance of C-reactive protein in osteoarthritis and total knee arthroplasty outcomes.

Authors:  Jessica W Smith; Thomas B Martins; Evelyn Gopez; Troy Johnson; Harry R Hill; Thomas D Rosenberg
Journal:  Ther Adv Musculoskelet Dis       Date:  2012-10       Impact factor: 5.346

4.  Interleukin-6 as a potential indicator for prevention of high-risk adenoma recurrence by dietary flavonols in the polyp prevention trial.

Authors:  Gerd Bobe; Paul S Albert; Leah B Sansbury; Elaine Lanza; Arthur Schatzkin; Nancy H Colburn; Amanda J Cross
Journal:  Cancer Prev Res (Phila)       Date:  2010-05-18

5.  The Integration of Emotional, Physiologic, and Communication Responses to Medical Oncology Surveillance Appointments During Breast Cancer Survivorship.

Authors:  Margaret F Clayton; Catherine Dingley; Gary Donaldson
Journal:  Cancer Nurs       Date:  2017 Mar/Apr       Impact factor: 2.592

6.  Severity of symptom flare after moderate exercise is linked to cytokine activity in chronic fatigue syndrome.

Authors:  Andrea T White; Alan R Light; Ronald W Hughen; Lucinda Bateman; Thomas B Martins; Harry R Hill; Kathleen C Light
Journal:  Psychophysiology       Date:  2010-03-04       Impact factor: 4.016

7.  Circulating levels of the innate and humoral immune regulators CD14 and CD23 are associated with adult glioma.

Authors:  Mi Zhou; Joseph L Wiemels; Paige M Bracci; Margaret R Wrensch; Lucie S McCoy; Terri Rice; Jennette D Sison; Joseph S Patoka; John K Wiencke
Journal:  Cancer Res       Date:  2010-08-18       Impact factor: 12.701

8.  Effects of serum and plasma matrices on multiplex immunoassays.

Authors:  Yael Rosenberg-Hasson; Leo Hansmann; Michaela Liedtke; Iris Herschmann; Holden T Maecker
Journal:  Immunol Res       Date:  2014-05       Impact factor: 2.829

9.  Simultaneous detection of eight analytes in human serum by two commercially available platforms for multiplex cytokine analysis.

Authors:  Gary Toedter; Karen Hayden; Carrie Wagner; Carrie Brodmerkel
Journal:  Clin Vaccine Immunol       Date:  2007-11-14

10.  Prerequisites for cytokine measurements in clinical trials with multiplex immunoassays.

Authors:  Wilco de Jager; Katarzyna Bourcier; Ger T Rijkers; Berent J Prakken; Vicki Seyfert-Margolis
Journal:  BMC Immunol       Date:  2009-09-28       Impact factor: 3.615

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.