Literature DB >> 15003798

The osteoporotic vertebral structure is well adapted to the loads of daily life, but not to infrequent "error" loads.

J Homminga1, B Van-Rietbergen, E M Lochmüller, H Weinans, F Eckstein, R Huiskes.   

Abstract

Osteoporotic vertebral fractures typically have a gradual onset, frequently remain clinically undetected, and do not seem to be related to traumatic events. The osteoporotic vertebrae may therefore be expected to display a less "optimal" bone architecture, leading to an uneven load distribution over the bone material. We evaluated the trabecular load distribution in an osteoporotic and a healthy vertebra under normal daily loading by combining three recent innovations: high resolution computed tomography (microCT) of entire bones, microfinite element analyses (microFEA), and parallel supercomputers. Much to our surprise, the number of highly loaded trabeculae was not higher in the osteoporotic vertebra than in the healthy one under normal daily loads (8% and 9%, respectively). The osteoporotic trabeculae were more oriented in the longitudinal direction, compensating for effects of bone loss and ensuring adequate stiffness for normal daily loading. The increased orientation did, however, make the osteoporotic structure less resistant against collateral "error" loads. In this case, the number of overloaded trabeculae in the osteoporotic vertebra was higher than in the healthy one (13% and 4%, respectively). These results strengthen the paradigm of a strong relationship between bone morphology and external loads applied during normal daily life. They also indicate that vertebral fractures result from actions like forward flexion or lifting, loads that may not be "daily" but are normally not traumatic either. If future clinical imaging techniques would enable such high-resolution images to be obtained in vivo, the combination of microCT and microFEA would produce a powerful tool to diagnose osteoporosis.

Entities:  

Mesh:

Year:  2004        PMID: 15003798     DOI: 10.1016/j.bone.2003.12.001

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  52 in total

Review 1.  Whole bone mechanics and bone quality.

Authors:  Jacqueline H Cole; Marjolein C H van der Meulen
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

2.  Vertebral body bone strength: the contribution of individual trabecular element morphology.

Authors:  I H Parkinson; A Badiei; M Stauber; J Codrington; R Müller; N L Fazzalari
Journal:  Osteoporos Int       Date:  2011-11-16       Impact factor: 4.507

3.  The Effect of Quantitative Computed Tomography Acquisition Protocols on Bone Mineral Density Estimation.

Authors:  Hugo Giambini; Dan Dragomir-Daescu; Paul M Huddleston; Jon J Camp; Kai-Nan An; Ahmad Nassr
Journal:  J Biomech Eng       Date:  2015-11       Impact factor: 2.097

4.  Simulated evolution of the vertebral body based on basic multicellular unit activities.

Authors:  Chao Wang; Chunqiu Zhang; Jingyun Han; Han Wu; Yubo Fan
Journal:  J Bone Miner Metab       Date:  2010-12-25       Impact factor: 2.626

Review 5.  A biomechanical perspective on bone quality.

Authors:  C J Hernandez; T M Keaveny
Journal:  Bone       Date:  2006-07-28       Impact factor: 4.398

6.  Does thoracic or lumbar spine bone architecture predict vertebral failure strength more accurately than density?

Authors:  E-M Lochmüller; K Pöschl; L Würstlin; M Matsuura; R Müller; T M Link; F Eckstein
Journal:  Osteoporos Int       Date:  2007-10-03       Impact factor: 4.507

7.  Locations of bone tissue at high risk of initial failure during compressive loading of the human vertebral body.

Authors:  Senthil K Eswaran; Atul Gupta; Tony M Keaveny
Journal:  Bone       Date:  2007-06-19       Impact factor: 4.398

8.  Role of trabecular microarchitecture in whole-vertebral body biomechanical behavior.

Authors:  Aaron J Fields; Senthil K Eswaran; Michael G Jekir; Tony M Keaveny
Journal:  J Bone Miner Res       Date:  2009-09       Impact factor: 6.741

9.  Effect of specimen-specific anisotropic material properties in quantitative computed tomography-based finite element analysis of the vertebra.

Authors:  Ginu U Unnikrishnan; Glenn D Barest; David B Berry; Amira I Hussein; Elise F Morgan
Journal:  J Biomech Eng       Date:  2013-10-01       Impact factor: 2.097

10.  Biaxial normal strength behavior in the axial-transverse plane for human trabecular bone--effects of bone volume fraction, microarchitecture, and anisotropy.

Authors:  Arnav Sanyal; Tony M Keaveny
Journal:  J Biomech Eng       Date:  2013-12       Impact factor: 2.097

View more