Literature DB >> 14766289

An automated high performance capillary liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometer for high-throughput proteomics.

Mikhail E Belov1, Gordon A Anderson, Mark A Wingerd, Harold R Udseth, Keqi Tang, David C Prior, Kenneth R Swanson, Michael A Buschbach, Eric F Strittmatter, Ronald J Moore, Richard D Smith.   

Abstract

We describe a fully automated high performance liquid chromatography 9.4 tesla Fourier transform ion resonance cyclotron (FTICR) mass spectrometer system designed for proteomics research. A synergistic suite of ion introduction and manipulation technologies were developed and integrated as a high-performance front-end to a commercial Bruker Daltonics FTICR instrument. The developments incorporated included a dual-ESI-emitter ion source; a dual-channel electrodynamic ion funnel; tandem quadrupoles for collisional cooling and focusing, ion selection, and ion accumulation, and served to significantly improve the sensitivity, dynamic range, and mass measurement accuracy of the mass spectrometer. In addition, a novel technique for accumulating ions in the ICR cell was developed that improved both resolution and mass measurement accuracy. A new calibration methodology is also described where calibrant ions are introduced and controlled via a separate channel of the dual-channel ion funnel, allowing calibrant species to be introduced to sample spectra on a real-time basis, if needed. We also report on overall instrument automation developments that facilitate high-throughput and unattended operation. These included an automated version of the previously reported very high resolution, high pressure reversed phase gradient capillary liquid chromatography (LC) system as the separations component. A commercial autosampler was integrated to facilitate 24 h/day operation. Unattended operation of the instrument revealed exceptional overall performance: Reproducibility (1-5% deviation in uncorrected elution times), repeatability (<20% deviation in detected abundances for more abundant peptides from the same aliquot analyzed a few weeks apart), and robustness (high-throughput operation for 5 months without significant downtime). When combined with modulated-ion-energy gated trapping, the dynamic calibration of FTICR mass spectra provided decreased mass measurement errors for peptide identifications in conjunction with high resolution capillary LC separations over a dynamic range of peptide peak intensities for each spectrum of 10(3), and >10(5) for peptide abundances in the overall separation.

Mesh:

Substances:

Year:  2004        PMID: 14766289     DOI: 10.1016/j.jasms.2003.09.008

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  39 in total

1.  High-throughput proteomics using high-efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry.

Authors:  Y Shen; N Tolić; R Zhao; L Pasa-Tolić; L Li; S J Berger; R Harkewicz; G A Anderson; M E Belov; R D Smith
Journal:  Anal Chem       Date:  2001-07-01       Impact factor: 6.986

2.  High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics.

Authors:  Yufeng Shen; Rui Zhao; Scott J Berger; Gordon A Anderson; Nestor Rodriguez; Richard D Smith
Journal:  Anal Chem       Date:  2002-08-15       Impact factor: 6.986

3.  Global analysis of the Deinococcus radiodurans proteome by using accurate mass tags.

Authors:  Mary S Lipton; Ljiljana Pasa-Tolic'; Gordon A Anderson; David J Anderson; Deanna L Auberry; John R Battista; Michael J Daly; Jim Fredrickson; Kim K Hixson; Heather Kostandarithes; Christophe Masselon; Lye Meng Markillie; Ronald J Moore; Margaret F Romine; Yufeng Shen; Eric Stritmatter; Nikola Tolic'; Harold R Udseth; Amudhan Venkateswaran; Kwong-Kwok Wong; Rui Zhao; Richard D Smith
Journal:  Proc Natl Acad Sci U S A       Date:  2002-08-12       Impact factor: 11.205

4.  Direct analysis and identification of proteins in mixtures by LC/MS/MS and database searching at the low-femtomole level.

Authors:  A L McCormack; D M Schieltz; B Goode; S Yang; G Barnes; D Drubin; J R Yates
Journal:  Anal Chem       Date:  1997-02-15       Impact factor: 6.986

5.  Fourier-transform mass spectrometry of large molecules by electrospray ionization.

Authors:  K D Henry; E R Williams; B H Wang; F W McLafferty; J Shabanowitz; D F Hunt
Journal:  Proc Natl Acad Sci U S A       Date:  1989-12       Impact factor: 11.205

6.  The codon Adaptation Index--a measure of directional synonymous codon usage bias, and its potential applications.

Authors:  P M Sharp; W H Li
Journal:  Nucleic Acids Res       Date:  1987-02-11       Impact factor: 16.971

7.  Femtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry.

Authors:  M Wilm; A Shevchenko; T Houthaeve; S Breit; L Schweigerer; T Fotsis; M Mann
Journal:  Nature       Date:  1996-02-01       Impact factor: 49.962

8.  Direct analysis of protein complexes using mass spectrometry.

Authors:  A J Link; J Eng; D M Schieltz; E Carmack; G J Mize; D R Morris; B M Garvik; J R Yates
Journal:  Nat Biotechnol       Date:  1999-07       Impact factor: 54.908

9.  High sensitivity Fourier transform ion cyclotron resonance mass spectrometry for biological analysis with nano-LC and microelectrospray ionization.

Authors:  T L Quenzer; M R Emmett; C L Hendrickson; P H Kelly; A G Marshall
Journal:  Anal Chem       Date:  2001-04-15       Impact factor: 6.986

10.  Counting individual sulfur atoms in a protein by ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry: experimental resolution of isotopic fine structure in proteins.

Authors:  S D Shi; C L Hendrickson; A G Marshall
Journal:  Proc Natl Acad Sci U S A       Date:  1998-09-29       Impact factor: 11.205

View more
  23 in total

1.  A proteomic study of the HUPO Plasma Proteome Project's pilot samples using an accurate mass and time tag strategy.

Authors:  Joshua N Adkins; Matthew E Monroe; Kenneth J Auberry; Yufeng Shen; Jon M Jacobs; David G Camp; Frank Vitzthum; Karin D Rodland; Richard C Zangar; Richard D Smith; Joel G Pounds
Journal:  Proteomics       Date:  2005-08       Impact factor: 3.984

2.  Comparison of aerobic and photosynthetic Rhodobacter sphaeroides 2.4.1 proteomes.

Authors:  Stephen J Callister; Carrie D Nicora; Xiaohua Zeng; Jung Hyeob Roh; Miguel A Dominguez; Christine L Tavano; Matthew E Monroe; Samuel Kaplan; Timothy J Donohue; Richard D Smith; Mary S Lipton
Journal:  J Microbiol Methods       Date:  2006-07-07       Impact factor: 2.363

3.  Application of the accurate mass and time tag approach to the proteome analysis of sub-cellular fractions obtained from Rhodobacter sphaeroides 2.4.1. Aerobic and photosynthetic cell cultures.

Authors:  Stephen J Callister; Miguel A Dominguez; Carrie D Nicora; Xiaohua Zeng; Christine L Tavano; Samuel Kaplan; Timothy J Donohue; Richard D Smith; Mary S Lipton
Journal:  J Proteome Res       Date:  2006-08       Impact factor: 4.466

Review 4.  Advances in proteomics data analysis and display using an accurate mass and time tag approach.

Authors:  Jennifer S D Zimmer; Matthew E Monroe; Wei-Jun Qian; Richard D Smith
Journal:  Mass Spectrom Rev       Date:  2006 May-Jun       Impact factor: 10.946

5.  Combining low and high mass ion accumulation for enhancing shotgun proteome analysis by accurate mass measurement.

Authors:  Richard L Wong; I Jonathan Amster
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-18       Impact factor: 3.109

6.  Normalization approaches for removing systematic biases associated with mass spectrometry and label-free proteomics.

Authors:  Stephen J Callister; Richard C Barry; Joshua N Adkins; Ethan T Johnson; Wei-Jun Qian; Bobbie-Jo M Webb-Robertson; Richard D Smith; Mary S Lipton
Journal:  J Proteome Res       Date:  2006-02       Impact factor: 4.466

7.  Fully automated four-column capillary LC-MS system for maximizing throughput in proteomic analyses.

Authors:  Eric A Livesay; Keqi Tang; Beverley K Taylor; Michael A Buschbach; Derek F Hopkins; Brian L LaMarche; Rui Zhao; Yufeng Shen; Daniel J Orton; Ronald J Moore; Ryan T Kelly; Harold R Udseth; Richard D Smith
Journal:  Anal Chem       Date:  2007-11-29       Impact factor: 6.986

8.  Improving protein identification sensitivity by combining MS and MS/MS information for shotgun proteomics using LTQ-Orbitrap high mass accuracy data.

Authors:  Bingwen Lu; Akira Motoyama; Cristian Ruse; John Venable; John R Yates
Journal:  Anal Chem       Date:  2008-02-15       Impact factor: 6.986

9.  An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies.

Authors:  Erin Shammel Baker; Eric A Livesay; Daniel J Orton; Ronald J Moore; William F Danielson; David C Prior; Yehia M Ibrahim; Brian L LaMarche; Anoop M Mayampurath; Athena A Schepmoes; Derek F Hopkins; Keqi Tang; Richard D Smith; Mikhail E Belov
Journal:  J Proteome Res       Date:  2010-02-05       Impact factor: 4.466

10.  Quantitative proteome analysis of human plasma following in vivo lipopolysaccharide administration using 16O/18O labeling and the accurate mass and time tag approach.

Authors:  Wei-Jun Qian; Matthew E Monroe; Tao Liu; Jon M Jacobs; Gordon A Anderson; Yufeng Shen; Ronald J Moore; David J Anderson; Rui Zhang; Steve E Calvano; Stephen F Lowry; Wenzhong Xiao; Lyle L Moldawer; Ronald W Davis; Ronald G Tompkins; David G Camp; Richard D Smith
Journal:  Mol Cell Proteomics       Date:  2005-03-07       Impact factor: 5.911

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.