Literature DB >> 30344400

Novel Use of Orbita Plates in Mandibular Body Fractures.

Sonal Anchlia1, Jigar M Dhuvad1, Dhruvi Shukla1, Rohit Kumar1, Nisarg Patel1, Vipul Nagavadiya1.   

Abstract

BACKGROUND: Isolated fractures of the mandibular body separate the dentate border and compress lower border when subjected to masticatory forces. This study aims at evaluating the efficacy of two Orbita plates in Champy's osteosynthesis lines along with achieving 3D configuration and preventing trauma to mental foramen. AIMS: (1) To achieve a near 3D configuration by fixing the terminal parts of both plates in contact with each other; (2) to preserve the mental nerve within the ellipse created by two Orbita plates; and (3) to prevent damage to the root apices from the upper plate.
MATERIALS AND METHODS: This study was performed on 20 patients with mandible body fracture through the mental foramina. With the intraoral vestibular approach, two Orbita miniplates were fixed in Champy's osteosynthesis lines. A geometrically closed quadrangular relationship was achieved in the shape of an ellipse, with the mental nerve emerging from it.
RESULTS: Fracture healing was optimum in all the cases along with satisfactory occlusion. Postoperative intermaxillary fixation was not required. Mental nerve function impairment was insignificant.
CONCLUSION: This served to achieve satisfactory functional outcomes in patients with mandible body fracture without injury to roots and along with achieving a geometrically close quadrangular relationship even where 3D miniplates cannot be placed.

Entities:  

Keywords:  3D; Mandible body fracture; Orbita plate; Paresthesia; Quadrangular

Year:  2018        PMID: 30344400      PMCID: PMC6181835          DOI: 10.1007/s12663-018-1082-7

Source DB:  PubMed          Journal:  J Maxillofac Oral Surg        ISSN: 0972-8270


  9 in total

1.  [The value of 3-dimensional plates in maxillofacial surgery].

Authors:  M Farmand; L Dupoirieux
Journal:  Rev Stomatol Chir Maxillofac       Date:  1992

Review 2.  The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review.

Authors:  Gary Greenstein; Dennis Tarnow
Journal:  J Periodontol       Date:  2006-12       Impact factor: 6.993

3.  Assessment of the anterior loop of the mandibular canal: A study using cone-beam computed tomography.

Authors:  Eduarda Helena Leandro do Nascimento; Maria Luiza Dos Anjos Pontual; Andréa Dos Anjos Pontual; Danyel Elias da Cruz Perez; José Natal Figueiroa; Marco Antônio Gomes Frazão; Flávia Maria de Moraes Ramos-Perez
Journal:  Imaging Sci Dent       Date:  2016-06-23

4.  Changing trends with mandibular fractures: a review of 1,067 cases.

Authors:  K L Fridrich; G Pena-Velasco; R A Olson
Journal:  J Oral Maxillofac Surg       Date:  1992-06       Impact factor: 1.895

5.  Transoral 2.0-mm locking miniplate fixation of mandibular fractures plus 1 week of maxillomandibular fixation: a prospective study.

Authors:  Ayman Chritah; Stewart K Lazow; Julius R Berger
Journal:  J Oral Maxillofac Surg       Date:  2005-12       Impact factor: 1.895

6.  Complications of treatment of mandibular fractures with compression plates.

Authors:  N Zachariades; I Papademetriou
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1995-02

7.  Complications in the use of compression plates in the treatment of mandibular fractures.

Authors:  M D Williams; M H Pearson; S M Milner
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1991-08

8.  The management of fractures of the mandible.

Authors:  R P Winstanley
Journal:  Br J Oral Maxillofac Surg       Date:  1984-06       Impact factor: 1.651

9.  Mandibular osteosynthesis by miniature screwed plates via a buccal approach.

Authors:  M Champy; J P Loddé; R Schmitt; J H Jaeger; D Muster
Journal:  J Maxillofac Surg       Date:  1978-02
  9 in total