Abstract

STUDY
DESIGN: The effect of cement augmentation of wedge-fractured vertebral bodies on spine segment compliance was studied in 16 cadaver specimens.
OBJECTIVES: 1) To assess the mechanical effects of cement augmentation of vertebral wedge fractures. 2) To determine whether a new reduction/injection procedure has the same mechanical effects as the established direct injection procedure. SUMMARY OF BACKGROUND DATA: Although wedge fractures cause pain and disability in hundreds of thousands of people, few effective treatments are available. Clinical studies have shown that cement augmentation, a new procedure, effectively relieves pain and restores mobility in patients suffering from weak or fractured vertebrae. However, only a few studies have examined the mechanics of vertebral augmentation.
METHODS: A wedge fracture was created in the middle vertebra of 16 three-vertebra cadaver spine segments. Neutral and full-load compliance of each fractured spine segment in flexion/extension and lateral bending were assessed by measuring the relative rotation of the vertebral bodies in response to applied moments. Eight of the fractured vertebral bodies were then augmented using direct injection, while the remaining eight fractured vertebral bodies were augmented using a combined reduction/injection procedure. Compliance of the augmented segments was then assessed.
RESULTS: Augmentation significantly reduced the neutral compliance (reduction of 25% +/- 23%) (mean +/- standard deviation) and the full-load compliance (reduction of 23% +/- 20%) in flexion/extension (P < 0.005). Augmentation also significantly reduced the neutral compliance (reduction of 34% +/- 20%) and the full-load compliance (reduction of 26% +/- 17%) in lateral bending (P < 0.0001). No significant difference was found between the two procedures for compliance reduction.
CONCLUSIONS: Augmentation of wedge fractures using both direct injection and reduction/injection reduces spine segment compliance significantly.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10685478     DOI: 10.1097/00007632-200001150-00004

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  25 in total

Review 1.  Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures.

Authors:  J M Mathis; J D Barr; S M Belkoff; M S Barr; M E Jensen; H Deramond
Journal:  AJNR Am J Neuroradiol       Date:  2001-02       Impact factor: 3.825

Review 2.  Vertebroplasty versus kyphoplasty: a comparison and contrast.

Authors:  John M Mathis; A Orlando Ortiz; Gregg H Zoarski
Journal:  AJNR Am J Neuroradiol       Date:  2004-05       Impact factor: 3.825

3.  Load shift of the intervertebral disc after a vertebroplasty: a finite-element study.

Authors:  G Baroud; J Nemes; P Heini; T Steffen
Journal:  Eur Spine J       Date:  2003-04-01       Impact factor: 3.134

4.  An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty.

Authors:  S M Belkoff; J M Mathis; H Deramond; L E Jasper
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

Review 5.  Percutaneous vertebroplasty as a treatment for osteoporotic vertebral compression fractures: a systematic review.

Authors:  Wendy T Ploeg; Albert G Veldhuizen; Bertram The; Maurits S Sietsma
Journal:  Eur Spine J       Date:  2006-07-06       Impact factor: 3.134

6.  Vertebroplasty and Kyphoplasty Can Restore Normal Spine Mechanics following Osteoporotic Vertebral Fracture.

Authors:  Jin Luo; Michael A Adams; Patricia Dolan
Journal:  J Osteoporos       Date:  2010-06-20

7.  [Surgical management of vertebral column metastatic disease].

Authors:  K-D Schaser; I Melcher; T Mittlmeier; A Schulz; J H Seemann; N P Haas; A C Disch
Journal:  Unfallchirurg       Date:  2007-02       Impact factor: 1.000

8.  Quantitative, 3D Visualization of the Initiation and Progression of Vertebral Fractures Under Compression and Anterior Flexion.

Authors:  Timothy M Jackman; Amira I Hussein; Cameron Curtiss; Paul M Fein; Anderson Camp; Lidia De Barros; Elise F Morgan
Journal:  J Bone Miner Res       Date:  2015-12-24       Impact factor: 6.741

9.  Digital Volume Correlation for Study of the Mechanics of Whole Bones.

Authors:  Amira I Hussein; Paul E Barbone; Elise F Morgan
Journal:  Procedia IUTAM       Date:  2012

10.  Height gain of vertebral bodies and stabilization of vertebral geometry over one year after vertebroplasty of osteoporotic vertebral fractures.

Authors:  Michael B Pitton; Nadine Morgen; Sascha Herber; Philipp Drees; Bertram Böhm; Christoph Düber
Journal:  Eur Radiol       Date:  2007-10-02       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.