Literature DB >> 14745557

Incisional abdominal hernia: the open mesh repair.

V Schumpelick1, U Klinge, K Junge, M Stumpf.   

Abstract

BACKGROUND: Mesh techniques are the methods of choice for the repair of incisional hernias since these are due to the formation of unstable scar tissue.
METHODS: We review the materials and techniques used in the repair of incisional hernias. We describe in detail the operative technique performed in our clinic, the pitfalls of the repair, and the overlap behind the xiphoid and the pubic bone.
RESULTS: Polypropylene is the material widely used for open mesh repair. New developments have led to low-weight, large-pore polypropylene prostheses, which are adjusted to the physiological requirements of the abdominal wall and permit a proper tissue integration. These meshes provide the possibility of forming a scar net instead of a stiff scar plate and therefore help to avoid former known mesh complications.
CONCLUSIONS: The ideal position for the mesh is the retromuscular sublay position where the force of the abdominal pressure holds the prosthesis against the deep surface of the muscles. The lowest incidence rates of recurrence have been reported for the retromuscular sublay repair; even after long-term follow-up recurrence rates of 10% are possible. Attaining such good results requires an adequate size of the mesh with sufficient overlap of at least 5-6 cm in all directions. Open mesh repair using modern low-weight polypropylene meshes in the retromuscular sublay technique offers excellent results for the treatment of incisional hernias.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14745557     DOI: 10.1007/s00423-003-0352-z

Source DB:  PubMed          Journal:  Langenbecks Arch Surg        ISSN: 1435-2443            Impact factor:   3.445


  19 in total

1.  Functional impairment and complaints following incisional hernia repair with different polypropylene meshes.

Authors:  G Welty; U Klinge; B Klosterhalfen; R Kasperk; V Schumpelick
Journal:  Hernia       Date:  2001-09       Impact factor: 4.739

2.  [Minimized polypropylene mesh for preperitoneal net plasty (PNP) of incisional hernias].

Authors:  V Schumpelick; B Klosterhalfen; M Müller; U Klinge
Journal:  Chirurg       Date:  1999-04       Impact factor: 0.955

3.  Woven Dacron and woven Teflon prostheses. Use for small artery replacement.

Authors:  T B MASSELL; E C HERINGMAN; S M GREENSTONE
Journal:  Arch Surg       Date:  1962-01

4.  [Preperitoneal prosthesis implantation in surgical management of recurrent inguinal hernia. Retrospective evaluation of our results 1989-1994].

Authors:  I Langer; U Herzog; J P Schuppisser; C Ackermann; P Tondelli
Journal:  Chirurg       Date:  1996-04       Impact factor: 0.955

5.  Incisional hernia treatment with progressive pneumoperitoneum and retromuscular prosthetic hernioplasty.

Authors:  Antonio Toniato; Costantino Pagetta; Paolo Bernante; Andrea Piotto; Maria Rosa Pelizzo
Journal:  Langenbecks Arch Surg       Date:  2002-09-26       Impact factor: 3.445

6.  Retrorectus prosthetic mesh repair of midline abdominal hernia.

Authors:  D McLanahan; L T King; C Weems; M Novotney; K Gibson
Journal:  Am J Surg       Date:  1997-05       Impact factor: 2.565

7.  Modifications to Rives technique for midline incisional hernia repair.

Authors:  A Martín-Duce; F Noguerales; R Villeta; P Hernández; O Lozano; J Keller; J Granell
Journal:  Hernia       Date:  2001-06       Impact factor: 4.739

8.  [The use of an underlay polypropylene mesh in complicated incisional hernias: sucessful French surgical technique].

Authors:  R Ladurner; A Trupka; S Schmidbauer; K Hallfeldt
Journal:  Minerva Chir       Date:  2001-02       Impact factor: 1.000

9.  Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair.

Authors:  B Klosterhalfen; U Klinge; V Schumpelick
Journal:  Biomaterials       Date:  1998-12       Impact factor: 12.479

10.  Greater risk of incisional hernia with morbidly obese than steroid-dependent patients and low recurrence with prefascial polypropylene mesh.

Authors:  H J Sugerman; J M Kellum; H D Reines; E J DeMaria; H H Newsome; J W Lowry
Journal:  Am J Surg       Date:  1996-01       Impact factor: 2.565

View more
  37 in total

1.  Incisional abdominal hernia: the open mesh repair.

Authors:  J A Halm; J W A Burger; J Jeekel
Journal:  Langenbecks Arch Surg       Date:  2004-05-20       Impact factor: 3.445

2.  Inflammatory reaction and neotissue maturation in the early host tissue incorporation of polypropylene prostheses.

Authors:  G Pascual; M Rodríguez; S Sotomayor; B Pérez-Köhler; J M Bellón
Journal:  Hernia       Date:  2012-06-29       Impact factor: 4.739

3.  [Treatment of abdominal wall defects, including abdominal relaxation].

Authors:  C Langer; H Becker
Journal:  Chirurg       Date:  2006-05       Impact factor: 0.955

4.  Incisional hernia: challenge of re-operations after mesh repair.

Authors:  Joachim Conze; Carsten J Krones; Volker Schumpelick; Uwe Klinge
Journal:  Langenbecks Arch Surg       Date:  2006-09-02       Impact factor: 3.445

Review 5.  Laparoscopic ventral hernia repair: is there an optimal mesh fixation technique? A systematic review.

Authors:  Emmelie Reynvoet; Ellen Deschepper; Xavier Rogiers; Roberto Troisi; Frederik Berrevoet
Journal:  Langenbecks Arch Surg       Date:  2014-01       Impact factor: 3.445

6.  Incisional hernia repair - laparoscopic or open surgery?

Authors:  Andrew Kingsnorth; Ayan Banerjea; Aman Bhargava
Journal:  Ann R Coll Surg Engl       Date:  2009-11       Impact factor: 1.891

7.  Effect of biomaterial design criteria on the performance of surgical meshes for abdominal hernia repair: a pre-clinical evaluation in a chronic rat model.

Authors:  Gabriela Voskerician; Judy Jin; Michael F White; Christina P Williams; Michael J Rosen
Journal:  J Mater Sci Mater Med       Date:  2010-03-10       Impact factor: 3.896

8.  The lateral incisional hernia: anatomical considerations for a standardized retromuscular sublay repair.

Authors:  M Stumpf; J Conze; A Prescher; K Junge; C J Krones; U Klinge; V Schumpelick
Journal:  Hernia       Date:  2009-02-12       Impact factor: 4.739

9.  A randomised, multi-centre, prospective, double blind pilot-study to evaluate safety and efficacy of the non-absorbable Optilene Mesh Elastic versus the partly absorbable Ultrapro Mesh for incisional hernia repair.

Authors:  Christoph Seiler; Petra Baumann; Peter Kienle; Andreas Kuthe; Jens Kuhlgatz; Rainer Engemann; Moritz V Frankenberg; Hanns-Peter Knaebel
Journal:  BMC Surg       Date:  2010-07-12       Impact factor: 2.102

10.  Open onlay mesh repair for major abdominal wall hernias with selective use of components separation and fibrin sealant.

Authors:  Andrew N Kingsnorth; M Kamran Shahid; Aby J Valliattu; Robert A Hadden; Christine S Porter
Journal:  World J Surg       Date:  2008-01       Impact factor: 3.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.