Literature DB >> 20532581

Diode-pumped solid-state laser for bonding orthodontic brackets: effect of light intensity and light-curing time.

Young-Oh Kim1, Soo-Byung Park, Woo-Sung Son, Ching-Chang Ko, Franklin García-Godoy, Hyung-Il Kim, Yong Hoon Kwon.   

Abstract

This study evaluated the shear bond strength (SBS) of orthodontic brackets bonded to teeth using a diode-pumped solid state (DPSS) laser of 473 nm with various light intensity and light-curing settings. For the study, a total of 150 extracted human teeth were divided into ten groups. In the control group, the brackets were bonded to the teeth using a quartz-tungsten-halogen (QTH) light with an intensity of 900 mW/cm(2). In the experimental groups, the brackets were bonded using a DPSS laser with three different light intensities and light-curing times. The same bracket type and adhesive were used in all groups throughout the study. Statistical analysis was performed to compare the SBS, and adhesive remnant index (ARI) among the groups. As results, brackets bonded using the DPSS laser with an intensity of 700 mW/cm(2) for 40 s (totally) showed a slightly higher SBS (12.2 ± 1.8 MPa) than that of those bonded using a QTH light (control; 11.6 ± 1.6 MPa). The SBS values linearly increased with increasing energy density (light intensity × light-curing time) of the DPSS laser (R = 0.95, p < 0.001). However, the SBS values among the test groups were similar regardless of the difference in light-curing conditions. A comparison of the ARI scores among the groups suggested a similar bracket failure mode.

Entities:  

Mesh:

Year:  2010        PMID: 20532581     DOI: 10.1007/s10103-010-0802-0

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  29 in total

1.  Composite conversion and temperature rise using a conventional, plasma arc, and an experimental blue LED curing unit.

Authors:  Z Tarle; A Meniga; A Knezević; J Sutalo; M Ristić; G Pichler
Journal:  J Oral Rehabil       Date:  2002-07       Impact factor: 3.837

2.  Time-based elution of TEGDMA and BisGMA from resin composite cured with LED, QTH and high-intensity QTH lights.

Authors:  Adil Nalçaci; Nuran Ulusoy; Orhan Atakol
Journal:  Oper Dent       Date:  2006 Mar-Apr       Impact factor: 2.440

3.  Marginal adaptation of composite restorations photoactivated by LED, plasma arc, and QTH light using low-modulus resin liners.

Authors:  Roberta Caroline Bruschi Alonso; Leonardo Gonçalves Cunha; Gisele Maria Correr; Regina Maria Puppin-Rontani; Lourenço Correr-Sobrinho; Mário Alexandre Coelho Sinhoreti
Journal:  J Adhes Dent       Date:  2006-08       Impact factor: 2.359

Review 4.  Argon laser: a light source alternative for photopolymerization and in-office tooth bleaching.

Authors:  Alessandra Cassoni; Jose Augusto Rodrigues
Journal:  Gen Dent       Date:  2007 Sep-Oct

5.  Comparison of the heat generation of light curing units.

Authors:  Bora Bagis; Yildirim Bagis; Ertan Ertas; Seda Ustaomer
Journal:  J Contemp Dent Pract       Date:  2008-02-01

6.  Laser effect on in vitro enamel permeability and solubility.

Authors:  R H Stern; R F Sognnaes; F Goodman
Journal:  J Am Dent Assoc       Date:  1966-10       Impact factor: 3.634

7.  Effect of composite shade, increment thickness and curing light on temperature rise during photocuring.

Authors:  A A Al-Qudah; C A Mitchell; P A Biagioni; D L Hussey
Journal:  J Dent       Date:  2006-10-06       Impact factor: 4.379

8.  Polymerization depths of contemporary light-curing units using microhardness.

Authors:  F A Rueggeberg; J W Ergle; D J Mettenburg
Journal:  J Esthet Dent       Date:  2000

9.  Comparison of PAC and QTH light sources on polymerization of resin composites.

Authors:  Nobuhiro Katahira; Richard M Foxton; Norimichi Inai; Masayuki Otsuki; Junji Tagami
Journal:  Am J Dent       Date:  2004-04       Impact factor: 1.522

10.  Hardness and wear resistance of two resin composites cured with equivalent radiant exposure from a low irradiance LED and QTH light-curing units.

Authors:  Lance C Ramp; James C Broome; Merrie H Ramp
Journal:  Am J Dent       Date:  2006-02       Impact factor: 1.522

View more
  1 in total

1.  Effect of a DPSS laser on the shear bond strength of ceramic brackets with different base designs.

Authors:  Mi-Gyoung Park; Jung-Hoon Ro; Jeong-Kil Park; Ching-Chang Ko; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2012-11-08       Impact factor: 3.161

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.