Literature DB >> 21417914

Influence of DPSS laser on polymerization shrinkage and mass change of resin composites.

Dong-Hee Shin1, Dong-In Yun, Mi-Gyong Park, Ching-Chang Ko, Franklin García-Godoy, Hyung-Il Kim, Yong Hoon Kwon.   

Abstract

OBJECTIVES: This study evaluated the effectiveness of the diode-pumped solid state (DPSS) laser as a light source for light-curing dental resin composites. BACKGROUND DATA: A DPSS laser of 473  nm may be useful because of its match with the absorption peak of camphorquinone (CQ), the photoinitiator.
MATERIALS AND METHODS: A DPSS laser (LAS) of 473  nm and a quartz-tungsten-halogen (QTH) light-curing unit (OP) were used as the light sources for light curing six different resin composites (four nanocomposites and two hybrid composites). Polymerization shrinkage and mass change (water sorption and solubility) were measured during and after light curing to determine the degree of polymerization. Mass change was evaluated by following the ISO 4049 standard.
RESULTS: According to the evaluation, the specimens light cured using LAS showed similar maximum polymerization shrinkage (12.3∼18.1  μm for LAS; 13.2∼16.2  μm for OP) and water sorption (11.4∼24.1  μg/mm(3) for LAS; 11.3∼22.8  μg/ mm(3) for OP) to the cases light cured using OP. The specimens light cured using LAS showed a significantly higher solubility than the cases light cured using OP (2.4∼6.6  μg/ mm(3) for LAS; 0.8∼1.6  μg/ mm(3) for OP). However, the maximum water sorption and solubility obtained from the specimens were lower than the values permitted by the ISO 4049 standard.
CONCLUSIONS: The results may suggest that the DPSS laser with an emission wavelength of 473  nm can be used as a light source for light-curing dental resin composites.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21417914      PMCID: PMC3180762          DOI: 10.1089/pho.2010.2897

Source DB:  PubMed          Journal:  Photomed Laser Surg        ISSN: 1549-5418            Impact factor:   2.796


  36 in total

1.  Sorption kinetics of ethanol/water solution by dimethacrylate-based dental resins and resin composites.

Authors:  Irini D Sideridou; Dimitris S Achilias; Maria M Karabela
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-04       Impact factor: 3.368

2.  Reaction kinetics and mechanics in photo-polymerised networks.

Authors:  David C Watts
Journal:  Dent Mater       Date:  2005-01       Impact factor: 5.304

3.  Influence of light intensity from different curing units upon composite temperature rise.

Authors:  A Knezević; Z Tarle; A Meniga; J Sutalo; G Pichler
Journal:  J Oral Rehabil       Date:  2005-05       Impact factor: 3.837

4.  DPSS yellow-green 561-nm lasers for improved fluorochrome detection by flow cytometry.

Authors:  William Telford; Matilde Murga; Teresa Hawley; Robert Hawley; Beverly Packard; Akira Komoriya; Fred Haas; Charles Hubert
Journal:  Cytometry A       Date:  2005-11       Impact factor: 4.355

5.  Importance of water sorption and solubility studies for couple bonding agent--resin-based filling material.

Authors:  Eric Mortier; David Alain Gerdolle; Bruno Jacquot; Marc M Panighi
Journal:  Oper Dent       Date:  2004 Nov-Dec       Impact factor: 2.440

6.  How different curing methods affect mechanical properties of composites for inlays when tested in dry and wet conditions.

Authors:  K K Kildal; I E Ruyter
Journal:  Eur J Oral Sci       Date:  1997-08       Impact factor: 2.612

7.  Shrinkage strain-rates of dental resin-monomer and composite systems.

Authors:  Mohammad Atai; David C Watts; Zahra Atai
Journal:  Biomaterials       Date:  2005-08       Impact factor: 12.479

8.  Time dependence of composite shrinkage using halogen and LED light curing.

Authors:  Alexander Uhl; Robin W Mills; Angelika E Rzanny; Klaus D Jandt
Journal:  Dent Mater       Date:  2005-03       Impact factor: 5.304

9.  Softening patterns of post-cure heat-treated dental composites.

Authors:  F Mante; N Saleh; M Mante
Journal:  Dent Mater       Date:  1993-09       Impact factor: 5.304

10.  Composites for use in posterior teeth: mechanical properties tested under dry and wet conditions.

Authors:  H Oysaed; I E Ruyter
Journal:  J Biomed Mater Res       Date:  1986-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.